Authorized nVent Distributor
nVent N360626G150 - SpectraCool Narrow Indoor/Outdoor AC with Heat, 6000 BTU 230V, Lt Gray, Steel

nVent N360626G150 SpectraCool Narrow Indoor/Outdoor AC with Heat, 6000 BTU 230V, Lt Gray, Steel

UPC: 783510238674


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent SpectraCool Narrow Indoor/Outdoor AC with Heat (SKU: N360626G150) delivers precise 6000 BTU of cooling and integrated heating in a compact, narrow-profile unit engineered for 12-inch (300-mm) deep enclosures. Constructed from durable steel with a light gray finish, this unit is built to withstand harsh conditions, including chemical exposure and corrosion, while maintaining reliable performance across an extreme ambient temperature range of -40°F to 131°F (-40°C to 55°C). The corrosion-resistant design ensures longevity in outdoor and industrial environments, including telecommunications shelters, control rooms, and outdoor electrical enclosures. For optimal cooling efficiency, the unit features a cleanable aluminum mesh filter that protects the coils, while a dust-resistant condenser coil enables filterless operation in most applications, reducing maintenance requirements. The narrow footprint maximizes space efficiency in tight installations, making it ideal for environments where space is limited. Powered by 230V, the unit integrates seamlessly with standard industrial power systems, providing year-round temperature regulation for sensitive equipment. Its robust construction and operational versatility make it a reliable solution for maintaining precise thermal control in demanding industrial and outdoor settings.
  • Narrow design accommodates 12-inch (300-mm) deep cabinets
  • Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
  • Attractive industrial design with minimal use of visible fasteners
  • Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing) side and an additional wrap around the thermostat
  • Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance
  • Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series)
  • Reliable mechanical thermostat on enclosure side of the unit; indoor air conditioner models include digital display on ambient side
  • Energy efficient rotary compressor on N36 and N43 models
  • Dust-resistant condenser coil allows the unit to be run filterless in most applications
  • Galvanized sheet-metal cover for rugged factory and outdoor environments

Specifications

Ambient Temperature
40 Deg C
Ambient Temperature
-40-131 °F
Amperage Rating
4.7;5.0 A;A
Amperage Rating
4.7/5.0 A
Application
Controls and Drives;Power Distribution
Btu Rating
6,000
Color
Light Gray
Color
Gray
Color Code
RAL 7035
Corrosion Resistant
No
Depth
356 mm
Depth
14 in
Finish
Powder Coated
Frequency Rating
50/60 Hz
Frequency Rating, Maximum
60 Hz
Frequency Rating, Minimum
50 Hz
Height
36 in
Height
914 mm
Material
Mild Steel
Material
Steel
Max Current
5 A
Mechanical Advantage
Galvanized Sheet Metal Standard (Optional: Stainless Steel)
Model
N36
Mounting
Side wall
Mounting Type
Floor/Wall-mount
Mounting Type
Wall/Floor Mount
Mounting Type
Floor and Wall Mount
NEMA Rating
4 Watertight
Nema Rating
Type 12, 3R, 4
Nominal Capacity Btu/h
6,000 Btu/h
Nominal Capacity Watts
1,757 W
Nominal Voltage
230 V
Number Of Phases
1
Operating Temperature
-40-55 °C
Operating Temperature
-40-55
Operating Temperature
-40-131 °F
Outdoor Installation
Yes
Phase
1
Power
949/1097 W
Product Family
SpectraCool
Protection Rating
NEMA Type 4
Refrigerant
R513A
Remote Access Control
No
Series
SpectraCool Narrow
Size
6000 BTU
Thickness
1.21 mm
Thickness
18 ga
Thickness
51.40mm (2.024")
Type
Air Conditioners
Voltage AC
200-250 V
Voltage Rating
230 V
Weight
114 lb
Weight
45 kg
Width
11.5 in
Width
292 mm
Package Dimensions (L x W x H)
18 IN x 14 IN x 38 IN
Package Dimensions (L x W x H)
45.72 cm x 35.56 cm x 96.52 cm
Package Weight (Imperial)
114.000 L
Package Weight (Metric)
51.710 kg
SpectraCool Narrow Indoor/Outdoor AC, 6000BTU 230V, Lt Gray, Steel

N360626G050

SpectraCool Narrow Indoor/Outdoor AC, 6000BTU 230V, Lt Gray, Steel
DTT 6201 230V SC 7035

13256241055

DTT 6201 230V SC 7035
AC UNIT 12-20000BTU 230V N3R/4

DTS3461C230N3GY

AC UNIT 12-20000BTU 230V N3R/4
InRow RC 300mm Chilled Water

ACRC301S

InRow RC 300mm Chilled Water
4000BTU 230V 50HZ SS Type 4X, Bulletin MCLG (SPECTRACOOL® Air Conditioner - N280415 Narrow SpectraCool), Size/Dims: 28.00x11.50x14.00, Material: SS Type 304, Finish:

N280425G051

4000BTU 230V 50HZ SS Type 4X, Bulletin MCLG (SPECTRACOOL® Air Conditioner - N280415 Narrow SpectraCool), Size/Dims: 28.00x11.50x14.00, Material: SS Type 304, Finish:
AIR COND, T50-1226-G131, Bulletin MCL (Air Conditioners - T50-1226), Size/Dims: 2.00x2.00x2.00, Material: Steel, Finish: Gray

T501226G131

AIR COND, T50-1226-G131, Bulletin MCL (Air Conditioners - T50-1226), Size/Dims: 2.00x2.00x2.00, Material: Steel, Finish: Gray
SpectraCool Narrow Indoor/Outdoor AC without Heat, 6000 BTU 115V, Lt Gray, Steel

N360616G100

SpectraCool Narrow Indoor/Outdoor AC without Heat, 6000 BTU 115V, Lt Gray, Steel
AIR COND, T50-1226-G500, Bulletin MCL (Air Conditioners - T50-1226), Size/Dims: 2.00x2.00x2.00, Material: Steel, Finish: Gray

T501226G500

AIR COND, T50-1226-G500, Bulletin MCL (Air Conditioners - T50-1226), Size/Dims: 2.00x2.00x2.00, Material: Steel, Finish: Gray

How to Install the N360626G150 Air Conditioner

Installation guide for mounting and wiring the N360626G150 SPECTRACOOL Air Conditioner.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting gasket kit, Copper conductors, Slow blow or HACR circuit breaker

  1. Inspect and Test Functionality

    Inspect the air conditioner for any damage that may have occurred during shipment. Test the unit for functionality before mounting. If the unit has been in a horizontal position, ensure it is upright for at least five (5) minutes before operating. Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply using copper conductors only. Ensure the minimum circuit ampacity is at least 125% of the amperage shown on the unit nameplate. Immediately after applying power, the evaporator blower should start. Operate the unit with the compressor running for five to ten minutes by setting the cooling thermostat or controller setpoint below the ambient temperature. Condenser air temperatures should become warmer than normal room temperatures within a few minutes after the condenser impellers start.

  2. Mount the Air Conditioner

    Install the mounting gasket kit to the air conditioner. Mount the air conditioner onto the enclosure, taking care not to damage the mounting gasket, as it forms the seal between the unit and the enclosure. Avoid dragging the unit on the enclosure with the gasket attached to prevent rips or tears.

  3. Wire the Unit

    Refer to the nameplate for specific electrical requirements. Wire the unit to a properly grounded power supply using copper conductors. The electrical circuit should be fused with a slow blow or HACR circuit breaker. Ensure no other equipment is connected to this circuit to prevent overloading. If the unit requires a remote-mounted thermostat, wire the thermostat outputs to the appropriate terminals on the 24 VAC terminal strip according to the correct wiring diagram.

  4. Set Thermostat

    Set the thermostat for the required cabinet temperature. Refer to the 'Sequence of Operation' section for details on thermostat adjustment and operation. For testing purposes only, the thermostat stop screw may be removed to allow settings below 70 F, but it must be replaced and verified afterward to prevent coil freeze-ups.

  5. Verify Operation

    Ensure the air conditioner is in an upright position during operation. Verify that the evaporator fan starts immediately after power is applied and that the condenser air temperatures increase within a few minutes of the condenser impellers starting.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.