Contact for Pricing
Overview
- Narrow design accommodates 12-inch (300-mm) deep cabinets
- Level 1 Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
- Attractive industrial design with minimal use of visible fasteners
- Level 2 Protection Include: Everything that was coated in Level 1, plus protective coatings applied to the evaporator (interior facing ) side and an additional wrap around the thermostat
- Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance
- Narrow design accommodates 12-inch deep cabinets
- R407C, R513A or R134a refrigerants
- Models for 115, 230 and 400/460 3-phase VAC power input
- Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series)
- Reliable mechanical thermostat on enclosure side of the unit; indoor air conditioner models include digital display on ambient side
Specifications
Ambient Temperature | 40 Deg C |
Ambient Temperature | -40 °F |
Application | Controls and Drives;Power Distribution |
Color | Gray |
Color | Brushed |
Corrosion Resistant | No |
Depth | 356 mm |
Depth | 14 in |
Finish | Brushed #3 |
Height | 28 IN |
Height | 711 mm |
Material | SS304 |
Material | Stainless Steel 304 |
Max Current | 2.5 A |
Mounting | Side wall |
Mounting Type | Floor and Wall Mount |
NEMA Rating | 4 Watertight |
Nominal Capacity Btu/h | 4,000 Btu/h |
Nominal Capacity Watts | 1,172 W |
Nominal Voltage | 460 V |
Number Of Phases | 1 |
Operating Temperature | -40 °C |
Operating temperature | -40 °F |
Outdoor Installation | Yes |
Product Family | SpectraCool |
Protection Rating | NEMA Type 4X |
Refrigerant | R513A |
Remote Access Control | No |
Series | SpectraCool Narrow Indoor/Outdoor AC |
Size | Narrow |
Thickness | 18 ga |
Thickness | 51.40mm (2.024") |
Type | Air Conditioners |
Voltage Rating | 460 V |
Weight | 97 lb |
Width | 292 mm |
Width | 11.5 in |
Package Dimensions (L x W x H) | 18 IN x 13.5 IN x 30 IN |
Package Dimensions (L x W x H) | 45.72 cm x 34.29 cm x 76.2 cm |
Package Weight (Imperial) | 97.000 L |
Package Weight (Metric) | 43.999 kg |
How to Install and Set Up the nVent SPECTRACOOL N28 Air Conditioner
This guide provides step-by-step instructions for the physical installation, electrical wiring, and initial setup of the nVent SPECTRACOOL N28 air conditioner, including optional digital thermostat configuration.
Estimated time: 1h
Tools needed:
Wrench, Ratchet Driver, Wire Strippers, Multimeter
Supplies needed:
Mounting Gasket Kit, Mounting Bolts, Copper Conductors, Slow Blow Fuse or HACR Circuit Breaker
- Inspect and Position the Air Conditioner
Inspect the air conditioner for any concealed damage from shipment. If the unit has been in a horizontal position, place it in an upright, vertical, or mounting position for a minimum of five minutes before proceeding. CAUTION: Do not operate the air conditioner while it is horizontal or on its side, back, or front, as this will cause permanent damage to the refrigeration compressor and void the warranty.
- Perform Initial Functional Test
Before mounting, test the unit for functionality. Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply using copper conductors only. Ensure minimum circuit ampacity is at least 125% of the nameplate amperage. Set the cooling thermostat or controller setpoint below the ambient temperature. Operate the compressor for five to ten minutes, verifying the evaporator blower starts and condenser air temperatures become warmer than room temperatures.
- Install Mounting Gaskets
Using the mounting gasket kit provided with the unit, carefully install the gaskets onto the air conditioner as illustrated in Figure 1 of the manual.
- Mount Air Conditioner
Mount the air conditioner onto the enclosure. Exercise caution to avoid damaging the mounting gasket, as it forms the watertight seal between the air conditioner and the enclosure. Do not drag the air conditioner on the enclosure once the gasket is attached, as this could cause rips or tears.
- Secure Mounting Bolts
To prevent cross-threading the mounting inserts, start all mounting bolts by hand before tightening them fully with a wrench or ratchet driver.
- Allow Unit to Stabilize
After mounting, ensure the unit remains in an upright position for a minimum of five minutes before initiating operation. The air conditioner must remain in an upright position during all operational periods.
- Connect to Main Power
Refer to the unit's nameplate for specific electrical requirements. Wire the air conditioner to a properly grounded power supply. The electrical circuit must be fused with a slow blow or HACR circuit breaker to prevent overloading.
- Wire Remote Thermostat (Optional)
If your air conditioner model requires a remote mounted thermostat, wire its outputs to the appropriate terminals on the 24 VAC terminal strip. Consult the correct wiring diagram provided in the manual for precise terminal locations and connections.
- Set Thermostat Setpoint
Adjust the thermostat to the desired cabinet temperature. For standard thermostats, refer to the 'Sequence of Operation' section on page 4 for adjustment and operation guidelines. For digital thermostats, proceed to the next steps for configuration.
- Energize Digital Controller (Optional)
If your unit is equipped with a digital thermostat controller, it is pre-wired and programmed at the factory. It will automatically operate when power is applied to the air conditioner. The evaporator fan should start within 30 seconds after self-evaluation, and the fan icon, along with inlet and outlet temperature data (if applicable), should illuminate on the display.
- Configure Digital Thermostat Settings (Optional)
To view or change the digital thermostat settings, press and hold the 'Keypad Select' button for 5 seconds to access the parameter menu. Use the 'Keypad Up' and 'Keypad Down' buttons to navigate through parameters and adjust variables. Hold the 'Keypad Select' button for 3 seconds to return to the main screen after saving any changes. Factory settings are pre-programmed.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.