- Narrow design accommodates 12-inch (300-mm) deep cabinets
- Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
- Attractive industrial design with minimal use of visible fasteners
- Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing) side and an additional wrap around the thermostat
- Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance
- Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series)
- Reliable mechanical thermostat on enclosure side of the unit; indoor air conditioner models include digital display on ambient side
- Energy efficient rotary compressor on N36 and N43 models
- Dust-resistant condenser coil allows the unit to be run filterless in most applications
- Galvanized sheet-metal cover for rugged factory and outdoor environments
Specifications
Ambient Temperature | 40 Deg C |
Ambient Temperature | -40-131 °F |
Application | Controls and Drives;Corrosive Environments;Power Distribution |
Color | Lt Gray |
Color | Light Gray |
Color | Gray |
Color Code | RAL 7035 |
Corrosion Resistant | Yes |
Depth | 6.3 in |
Depth | 160 mm |
Finish | Powder Coated |
Height | 16.51 in |
Height | 419 mm |
Material | Mild Steel |
Material | Steel |
Max Current | 1.5 A |
Mechanical Advantage | Stainless steel optional |
Mounting | Side wall |
Mounting Type | Floor and Wall Mount |
NEMA Rating | 12 Indoor, dust-resistant |
Nema Rating | NEMA Type II |
Nominal Capacity Btu/h | 800 Btu/h |
Nominal Capacity Watts | 235 W |
Nominal Voltage | 230 V |
Number Of Phases | 1 |
Operating Temperature | -40-55 |
Operating Temperature | -40-55 °C |
Operating Temperature | -40-131 °F |
Outdoor Installation | Yes |
Poles | 1P |
Product Family | SpectraCool |
Protection Rating | NEMA Type 12 |
Refrigerant | R513A |
Remote Access Control | Yes |
Series | SpectraCool Compact |
Thickness | 1.21 mm |
Thickness | 18 ga |
Thickness | 51.40mm (2.024") |
Type | Air Conditioners |
Voltage AC | 200-250 V |
Voltage Rating | 230 V |
Weight | 27 lb |
Weight | 12 kg |
Width | 7.52 in |
Width | 191 mm |

T501226G173P
The nVent T501226G173P represents a critical component within industrial electrical systems, designed and manufactured in the United States by nVent, a globally recognized leader in electrical enclosure and connection solutions. While specific catalog details for this SKU are not provided, its UNSPSC code (40101701) indicates its classification within the "Electrical components" category, suggesting a role in power distribution, control, or protection. Industrial environments demand robust, reliable, and safe electrical infrastructure. Components like the T501226G173P are engineered to withstand harsh operating conditions, including extreme temperatures, corrosive atmospheres, vibration, and potential electrical surges. The "T501226G173P" designation itself, coupled with the nVent brand, implies a product built to stringent quality standards, ensuring longevity and operational integrity. Professionals in sectors such as manufacturing, oil and gas, utilities, and heavy industry rely on such components for the seamless and secure functioning of their operations. When selecting industrial electrical components, key considerations include: * **Durability and Material Quality:** The materials used must resist environmental degradation and mechanical stress. nVent is known for utilizing high-grade materials in their product lines. * **Performance Specifications:** While not detailed here, typical components in this UNSPSC category would have specifications related to voltage ratings, current carrying capacity, ingress protection (IP) ratings, and operating temperature ranges. * **Compliance and Certifications:** Industrial products must meet relevant safety and performance standards, often including UL, CSA, or IEC certifications, depending on the application and region. * **Ease of Installation and Maintenance:** Efficient installation and straightforward maintenance procedures are crucial for minimizing downtime and operational costs. The nVent T501226G173P, originating from the US, benefits from a manufacturing environment known for its emphasis on precision engineering and quality control. nVent's extensive experience in providing comprehensive electrical solutions means that components like this are designed to integrate seamlessly into larger systems, offering a high degree of reliability. Whether it's part of a control panel, a power distribution unit, or a specialized enclosure, the T501226G173P is a testament to nVent's commitment to delivering dependable electrical infrastructure for the most demanding industrial applications. Its presence signifies a dedication to operational continuity and safety within critical industrial processes.How to Install the N160126G360 Air Conditioner
Installation guide for mounting and wiring the N160126G360 air conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wrench, Ratchet driver
Supplies needed:
Gasket kit, Mounting bolts, Mounting screws, Drain tube
- Verify Functionality
Inspect the air conditioner and verify correct functionality before mounting. If the unit has been in a horizontal position, ensure it has been upright for at least 5 minutes before testing. Refer to the nameplate for electrical requirements and connect to a properly grounded power supply. The evaporator blower should start immediately. Operate for 5-10 minutes, checking for excessive noise or vibration. Both blowers and the compressor should be running, and condenser air should be warmer than room temperature.
- Prepare Enclosure
Using the cutout dimensions provided in the manual, prepare the air "IN" and air "OUT" openings, and the mounting bolt hole pattern for the enclosure. Ensure adequate ventilation and clearance for service. Maintain at least 24" from the front, 2" from the right side, 8" from the left side, and 6" from the top. The distance between the air conditioner and other internal components must be at least 3".
- Install Gaskets
Using the provided gasket kit, install gaskets onto the air conditioner.
- Mount the Air Conditioner
Mount the air conditioner onto the enclosure using the provided mounting bolts and screws. "EZ" mount tabs can assist in holding the unit in place. Ensure the unit remains upright for a minimum of 5 minutes before starting operation. Start bolts by hand before tightening with a wrench or ratchet driver to avoid cross-threading.
- Route Drain Tube
Carefully route the drain tube, ensuring it is on a continuous downward slope and does not kink or elevate above the exit point. Improper routing can lead to condensate drain pan overflow.
- Connect Power
Refer to the top of the nameplate for electrical requirements. Connect the power cord or wire the unit to a properly grounded power supply. Use of an extension cord is not recommended. If wiring directly, the electrical circuit should be fused with a time delay fuse or HACR circuit breaker per the MOPD rating. Ensure no other equipment is connected to this circuit to prevent overloading.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.