Contact for Pricing
Overview
- Description: Four U-section side pieces fixed by screws to the corner sections. Plinth height 100 mm. Machining is required.
- Material: 2 mm AISI 304 / AISI 316L pre-grained stainless steel.
- Finish: 400 pre-grained stainless steel.
- Pack quantity: 1 plinth with mounting material.
- Benefit: installing cables into the console can be done easily as the plinth creates extra space below the console; plinth base allows consoles to be fixed to the floor without the need for interior access
Specifications
Application | Controls and Drives; Factory Automation and Process Control |
Depth | 11.81 in |
Depth | 300 mm |
Enclosure Material | Mild Steel |
Finish | Brushed |
Height | 100 mm |
Height | 3.94 in |
Material | Stainless Steel 304 |
Product Family | Wall Mounted |
Thickness | 2 mm |
Thickness | 0.08 in |
Type | Fixing |
Weight | 6 kg |
Weight | 13.23 lb |
Width | 1,000 mm |
Width | 39.37 in |
Works With | IEC |
Package Dimensions (L x W x H) | 39.75 IN x 4.31 IN x 40 IN |
Package Dimensions (L x W x H) | 100.965 cm x 10.9474 cm x 101.6 cm |
Package Weight (Imperial) | 16.300 L |
Package Weight (Metric) | 7.394 kg |

BMB164SL
A hardware accessory made of pre-galvanized steel. It uses slider mounting and is sized at 16 inches. The sheet provides no additional dimensional or application details beyond these listed attributes.How to Install the MSVS1103 Controller
This guide provides step-by-step instructions for installing and configuring the MSVS1103 Controller on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the MSVS1103 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect the wiring
Use terminal connectors to connect the power and signal wires to the appropriate terminals on the MSVS1103. Ensure all connections are tight and secure.
- Verify the installation
Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. Confirm that all connections are properly secured.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.