nVent MPP0805 - Partial Height Mounting Plates, MPP, 694x394x25mm, Galvanized, Mild Steel
nVent

MPP0805

UPC: 783510513641


Documents & Media
Installation InstructionsVideo Clip

Contact for Pricing

Overview

The nVent MPP0805 (SKU: MPP0805) is a partial height mounting plate designed for floor-standing enclosures, providing an optimized installation surface without consuming full enclosure depth. Constructed from 3 mm galvanized mild steel, it delivers robust durability and corrosion resistance for industrial environments. With dimensions of 694 mm (height) x 394 mm (width) x 25 mm (depth), this mounting plate is ideal for components that do not require a full-height plate, such as control panels, automation systems, and power distribution units. Engineered for straightforward installation, the MPP0805 supports single-person assembly and allows pre-configuration of devices before mounting. Its design enhances flexibility in enclosure layout and cable management, making it a practical choice for optimizing internal space. The galvanized steel construction ensures longevity in harsh industrial settings, while the partial height design reduces material usage and weight compared to full-height alternatives. Compatible with nVent floor-standing enclosures, the MPP0805 is part of a modular system that supports efficient space utilization and scalable configurations. It is distributed with mounting accessories and is manufactured in the US, adhering to nVent’s standards for quality and reliability.
  • Description: Mounted directly on the enclosure's frame or onto the click-in profiles (CLPK). Special design of the bracket allows one man assembly. Can be mounted in any height or depth position within the 25 mm hole pattern. Appropriate sizes can also b
  • Material: 3 mm galvanized steel.
  • Pack quantity: 1 plate with mounting accessories.
  • Mounting requirements: Add CLPK for depth adjustment.
  • Note: MPP can be mounted in both directions.

Specifications

Application
Controls and Drives; Power Distribution; Factory Automation and Process Control
Application
Controls and Drives; Factory Automation and Process Control
Color
Unpainted
Compatible Enclosure Height
800-800 mm
Compatible Enclosure Height
31.5-31.5 in
Compatible Enclosure Width
19.69-19.69 in
Compatible Enclosure Width
500-500 mm
Consist of
Partial Height Mounting Plates; Mounting Components and Instruction Manual
Construction
11 gauge
Depth
25 mm
Depth
0.96 in
Enclosure Material
Mild Steel
Finish
Galvanized
Height
694 mm
Height
27.32 in
Material
Mild Steel
Package Quantity
1
Product Family
Free-Standing
Size
27.32 x 15.51 x 0.96 inch
Thickness
3 mm
Thickness
11 ga
Type
Mounting
Type
IEC Enclosure Accessories
Weight
7.5 kg
Weight
16.61 lb
Width
394 mm
Width
15.51 in
Works With
IEC
Package Dimensions (L x W x H)
31.87 IN x 20.06 IN x 8 IN
Package Dimensions (L x W x H)
80.9498 cm x 50.9524 cm x 20.32 cm
Package Weight (Imperial)
16.610 L
Package Weight (Metric)
7.534 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the MPP0805 Controller

This guide provides step-by-step instructions for installing and configuring the MPP0805 Controller on a DIN rail.

Estimated time: 30m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the MPP0805 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Use terminal connectors to connect the power supply wires to the designated input terminals on the controller. Verify that the connections are secure.

  3. Configure the controller settings

    Power on the controller and use the configuration interface to set the desired parameters. Follow the on-screen prompts to complete the setup.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure outlined in the user manual. Ensure all readings are within specified limits.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.