Overview

The nVent MCSS Modular Single Door Stainless Steel Floor Standing Enclosure (SKU: MCSS18085) provides robust protection for critical electrical and automation equipment. Constructed from AISI 304L or AISI 316L pre-grained stainless steel, it offers superior corrosion resistance, making it suitable for food and beverage, pharmaceutical, chemical processing, and outdoor applications. The enclosure features a seam-welded frame with a 1.5 mm thickness and a 25 mm hole pattern per DIN 43660 for easy component mounting. The 2 mm thick door, 1.5 mm rear, roof, and side panels, and 1.5 mm bottom plates ensure durability. It boasts an IP 55 protection rating against dust and water jets and an IK 10 rating for impact resistance. The included 3 mm galvanized steel mounting plate provides a secure base for equipment. Designed for combinability, this enclosure can be integrated with other units for larger solutions. Manufactured in the USA, it meets Type 12 and Type 13 requirements, preventing costly downtime due to environmental ingress.
  • Constructed from AISI 304L or AISI 316L pre-grained stainless steel for corrosion resistance.
  • IP 55 protection rating against dust ingress and low-pressure water jets.
  • IK 10 impact resistance for enhanced durability.
  • 1800mm (H) x 800mm (W) x 500mm (D) dimensions with a single door.
  • Frame with 25 mm hole pattern (DIN 43660) for easy component mounting.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system. Does not interfere with the enclosure inner space. Standard double-bit 3 mm insert. Standard inserts, cylinders, lift handles and T-handle are available as accessories.
  • Bottom plates: One piece bottom plate, with injected polyurethane gasket to ensure maximum sealing.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Mounting plate is supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and are equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
16 ga
Body Thickness
1.5 mm
Cable Entry
No
Color
Unpainted
Color
Brushed Stainless
Construction
Body: 16 gauge Door: 14 gauge
Depth
19.69
Depth
500
Depth
500 mm
Door Thickness
14 ga
Finish
Brushed
Height
70.87
Height
1,800
Height
1,800 mm
IP Rating
IP55
Material
Stainless Steel
Material
AISI 304L or AISI 316L Stainless Steel
Mounting
Free Standing
Mounting Type
Floor-standing
Nema Rating
Type 12, Type 13
NEMA Rating
12
NEMA Rating
NEMA Type 12
Protection Rating
NEMA Type 12
Series
MCSS
Size
1800x800x500mm
Size
70.87 x 31.5 x 19.69 inch
Type
Stainless Steel Modular Industrial Enclosures
Weight
280.9 lb
Weight
32 lbs./100ft
Width
31.5
Width
800
Width
800 mm
Package Dimensions (L x W x H)
31.87 IN x 20.31 IN x 71.24 IN
Package Dimensions (L x W x H)
80.9498 cm x 51.5874 cm x 180.9496 cm
Package Weight (Imperial)
280.900 L
Package Weight (Metric)
127.416 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the MCSS18085 Controller

This guide provides step-by-step instructions for mounting, wiring, and configuring the MCSS18085 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the MCSS18085 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power supply and communication wires to the designated terminals on the controller. Verify that all connections are tight and secure.

  3. Configure the controller settings

    Power on the controller and use the configuration software to set the desired parameters. Follow the on-screen instructions to complete the setup.

  4. Calibrate the controller

    Perform a calibration check by following the calibration procedure in the software. Adjust settings as necessary to ensure accurate operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.