nVent MCS20106R53R Modular Single Door Type 3R, MCS-3R, 2000x1000x600mm, Light Gray, Mild Steel
UPC: 783510582722
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660 Including integrated external hole pattern
- Door: Mounted with four hinges allowing left or right hand opening; including door frame with 25 mm hole pattern
- Rear panel: Fitted by M6 torx screws; standard facilities for rear door mounting
- Supplied as an accessory
- Removable roof panel
- Lock: Espagnolette 4-point locking system which does not interfere with the enclosure inner space; standard double-bit lock with 3 mm insert
- Bottom plate: Consists of three or four (D>600) pieces
- Mounting plate: Double folded and slides into position with adjustable depths of 25 mm, with the MPD02 accessory
- Earthing/Grounding: All panels are earthed through their fittings and are equipped with a separate earthing stud
- Mounting requirements: Standard delivery ready for combined installation; for stand-alone installation add side panels
Specifications
Application | Controls and Drives;Factory Automation and Process Control |
Color | Light Gray |
Color | Gray |
Color | Grey |
Color Code | RAL 7035 |
Depth | 600 mm |
Depth | 23.62 in |
Finish | Powder Coating |
Height | 78.74 in |
Height | 2,000 mm |
IP Rating | IP55 |
Material | Mild Steel |
Mounting Type | Floor-standing |
NEMA Rating | Type 3R |
Protection Rating | NEMA Type 3R |
Series | MCS-3R |
Size | 2000x1000x600mm |
Thickness | 51.40mm (2.024") |
Thickness | 16 ga |
Type | Mild Steel Modular Industrial Enclosures |
Weight | 365 lb |
Weight | 32 lbs./100ft |
Width | 39.37 in |
Width | 1,000 mm |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackFrequently Asked Questions
What are the dimensions of the MCS20106R53R enclosure?
The enclosure has a height of 78.74 inches, a width of 39.37 inches, and a depth of 23.62 inches.
What material is the MCS20106R53R enclosure made of?
The enclosure is constructed from mild steel with a powder-coated finish in light gray (RAL 7035).
What is the protection rating of the MCS-3R enclosure range?
The MCS-3R enclosure range offers IP 55 and Type 3R protection degrees, preventing water and dust entry.
What industry standards does the MCS20106R53R enclosure meet?
It meets UL 50, 50E Listed; Type 3R; File No. E27525, cUL Listed per CSA C22.2 No. 94; Type 3R; File No. E27525, NEMA/EEMAC Type 3R, and IEC 62208 IP55.
How is the door of the enclosure mounted and how does it open?
The door is mounted with four hinges, allowing for either left or right-hand opening, and includes a door frame with a 25 mm hole pattern.
What type of locking system does the enclosure use?
It features an Espagnolette 4-point locking system with a standard double-bit lock and a 3 mm insert, designed not to interfere with inner space.
How is the mounting plate installed in the enclosure?
The mounting plate is double folded and slides into position, with adjustable depths of 25 mm, and can be used with the MPD02 accessory.
How are the panels earthed or grounded?
All panels are earthed through their fittings and are equipped with a separate earthing stud for grounding.
What is required for a stand-alone installation of this enclosure?
For a stand-alone installation, side panels must be added to close the cabinets, and SPM-3R steel side panels must be ordered separately.
What hardware is included in the delivery of the enclosure?
Delivery includes the frame with fitted door, rear panel, roof panel, bottom plates, mounting plate, door frame, and earthing bolts.
How to Assemble an MCS-3R Floor Standing Enclosure
This guide provides step-by-step instructions for assembling the various components of an MCS-3R floor standing enclosure, including panels, doors, and handles, ensuring proper torque for all fasteners.
Estimated time: 1h 30m
Tools needed:
T30 Torx screwdriver, T25 Torx screwdriver, SW13 Wrench/Socket, SW10 Wrench/Socket, SW3 Wrench/Socket, SW19 Wrench/Socket, Torque wrench
Supplies needed:
M5x10 screws, M6x12 screws, M12x20 screws, M8x16 screws, St. 5.5x10 screws, Metal Guider, BG01 Sealing Kit (for IP55, ordered separately), Floor plate (if mounting on combustible surface)
- Prepare the Mounting Surface and Enclosure Components
If mounting on or over a combustible surface, install a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel, extending at least 150 mm beyond the equipment on all sides. To maintain the enclosure's environmental integrity, use devices with the same environmental ratings to close any customized openings. Gather all necessary enclosure components, screws, and tools.
- Assemble the Enclosure Frame (Initial)
Attach the first set of frame components (parts 1 and 2) using M5x10 screws. Tighten to a torque of 4-5.5 Nm. Attach the second set of frame components (parts 3 and 4) using M5x10 screws. Tighten to a torque of 4-5.5 Nm. Install the Metal Guider using M5x10 screws, tightening to a torque of 4-5.5 Nm.
- Mount the Lift Handle Locking System
Attach the lift handle locking system (part 1) to the door (part 2) using a T30 Torx screwdriver. Rotate the cam (part 3) 180 degrees. Secure part 4 of the lift handle mechanism.
- Install the Standard Locking System (if applicable)
Attach the locking system components using M6x12 screws. Tighten to a torque of 15-20 Nm. Attach additional locking components using M12x20 screws. For the first tightening, apply a torque of 8-9 Nm. For subsequent tightenings, apply 4-5 Nm.
- Attach the Top Panel
Position the top panel onto the enclosure frame. Secure the top panel using M5x10 screws and M6x12 screws (if the enclosure is 1000mm wide or above). Tighten all screws to a torque of 4-5 Nm.
- Attach the Back Panel
Position the back panel onto the enclosure frame. Secure the back panel using the appropriate screws (Ref. A, B, C, with Ref. C used only on 1200mm wide enclosures). Tighten all screws to a torque of 4.5-5 Nm.
- Mount the Bottom Plates
Position the bottom plates (left and right) into the enclosure base. Secure the bottom plates using M8x16 screws and St. 5.5x10 screws. Tighten all screws to a torque of 10-15 Nm.
- Seal the Bottom Plates (for IP55 rating)
Install the BG01 sealing kit (ordered separately) to ensure the enclosure achieves an IP55 environmental rating.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.