Authorized nVent Distributor
nVent MCD18125R5 - Modular Double Door, with Plate, Rear Panel, 1800x1200x500mm, Gray, Mild Steel

nVent MCD18125R5 Modular Double Door, with Plate, Rear Panel, 1800x1200x500mm, Gray, Mild Steel

UPC: 783510490737


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent MCD18125R5 is a modular, double-door, floor-standing enclosure designed for space-constrained industrial environments. Measuring 1800x1200x500mm, it provides substantial internal volume for housing electrical and control components while optimizing access via two doors. The enclosure features a 1.5mm painted steel frame, 2mm painted steel doors, and 1.5mm painted steel rear, roof, and side panels, with a 3mm galvanized steel mounting plate included. Doors are mounted with four hinges and secured using an espagnolette 4-point locking system on the main door and 2-point on the secondary door. Its modular design allows for seamless combination with other MCD series units, enabling scalable control and distribution systems. The enclosure is supplied with rear panel, roof panel, bottom plates, and earthing bolts, ready for combined installation. Ideal for motor control centers, power distribution, automation systems, and telecommunications equipment.
  • Material: Frame: 1.5 mm painted steel. Doors: 2 mm painted steel. Rear, roof and side panels: 1.5 mm painted steel. Mounting plate: 3 mm galvanized steel. Bottom plates: 1 mm galvanized steel.
  • Frame: Seam welded reversed open profiles with 25 mm hole pattern, according to DIN 43660. Including integrated external hole pattern.
  • Doors: Mounted with four hinges. Including door frame with 25 mm hole pattern. Doors cannot be reversed. Separate doors to be ordered for left hand door locking.
  • Rear panel: Fitted by M6 torx screws. Standard facilities for rear doors mounting. Split rear panels in 1600 mm wide enclosures. RD version comes with rear door instead of rear panel.
  • Side panels: Supplied as an accessory.
  • Roof panel: Removable.
  • Lock: Espagnolette 4-point locking system in the main door and 2-point locking system in the secondary door. Standard double-bit lock with 3 mm insert. Standard inserts, cylinders, lift handles and T-handles are available as accessories.
  • Bottom plates: Consists of three or four (D>600) pieces.
  • Mounting plate: Double folded and slides into position. Adjustable in depth by steps of 25 mm, with the MPD02 accessory. Supplied, attached on the outside of the enclosure packaging.
  • Earthing: All panels are earthed through their fittings and equipped with a separate earthing stud.

Specifications

Application
Controls and Drives;Factory Automation and Process Control
Body Thickness
16 ga
Body Thickness
1.5 mm
Cable Entry
No
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Construction
Body: 16 gauge Door: 14 gauge
Depth
500
Depth
19.69 in
Depth
500 mm
Door Thickness
14 ga
Finish
Powder Coating
Finish
Powder Coated
Height
70.87 in
Height
1,800 mm
Height
1,800
IP Rating
IP55
Material
Mild Steel
Max Mounting Depth
11.1 in
Max Mounting Depth
18.07 in
Mounting
Free Standing
Mounting Plate Height
1,694;66.7 mm;mm
Mounting Plate Included
Yes
Mounting Plate Width
43.07 in
Mounting Type
Floor-Stand
Mounting Type
Floor-standing
NEMA Rating
12
NEMA Rating
NEMA Type 12
Protection Rating
NEMA Type 12
Rear Door Included
No
Rear Panel Included
Yes
Series
MCD
Size
1800x1200x500mm
Size
70.87 x 47.24 x 19.69 inch
Type
Mild Steel Modular Industrial Enclosures
Weight
390.36 lb
Width
47.24 in
Width
1,200 mm
Width
1,200
Package Dimensions (L x W x H)
47.62 IN x 20.31 IN x 71.24 IN
Package Dimensions (L x W x H)
120.9548 cm x 51.5874 cm x 180.9496 cm
Package Weight (Imperial)
390.360 L
Package Weight (Metric)
177.067 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

Frequently Asked Questions

What are the dimensions of the MCD18125R5 enclosure?

The enclosure has a height of 70.87 inches, a width of 47.24 inches, and a depth of 19.69 inches.

What material is the MCD18125R5 enclosure made of?

The enclosure is constructed from mild steel, with painted steel for the frame, doors, rear, roof, and side panels, and galvanized steel for the mounting and bottom plates.

What is the protection degree of the MCD18125R5 enclosure?

The enclosure complies with IP55, Type 12, and IK 10 protection ratings.

Does the MCD18125R5 enclosure include a mounting plate?

Yes, a mounting plate is included with the enclosure. It is 3 mm thick galvanized steel.

What are the dimensions of the included mounting plate?

The included mounting plate has a height of 66.7 mm and a width of 43.07 inches.

Can the doors of the MCD18125R5 enclosure be reversed?

No, the doors of this enclosure cannot be reversed. Separate doors must be ordered for left-hand door locking.

What type of locking system does the MCD18125R5 enclosure use?

It features an Espagnolette 4-point locking system on the main door and a 2-point system on the secondary door, with a standard double-bit lock.

Are side panels included with the MCD18125R5 enclosure?

No, side panels are supplied as an accessory and must be ordered separately to maintain the protection rating for stand-alone installations.

What are the industry standards the MCD18125R5 enclosure complies with?

It is UL 508A Listed (Type 12), cUL Listed (Type 12), NEMA/EEMAC Type 12, CSA certified (Type 12), and complies with IEC 62208.

What is the body and door thickness of the MCD18125R5 enclosure?

The body thickness is 16 gauge, and the door thickness is 14 gauge.

How to Install the MCD18125R5 Controller

This guide provides step-by-step instructions for installing and configuring the MCD18125R5 Controller, ensuring proper setup and operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, Terminal blocks

  1. Mount the controller

    Secure the MCD18125R5 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Connect the power supply wires to the appropriate terminals on the controller. Ensure that the connections are tight and insulated to prevent short circuits.

  3. Wire the input/output connections

    Connect the input and output devices to the corresponding terminals on the controller. Use wire connectors to secure the connections and verify that they are correctly wired according to the wiring diagram.

  4. Configure the controller settings

    Power on the controller and access the configuration menu. Set the desired parameters for operation, including speed, torque, and any other relevant settings.

  5. Calibrate the controller

    Perform a calibration procedure as per the manufacturer's guidelines to ensure accurate operation. This may involve running the controller through a series of tests to confirm its performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.