Contact for Pricing
Overview
- 28-inch slim-profile fluorescent enclosure light for optimal space utilization.
- 120V operation for compatibility with standard industrial power.
- Durable black plastic construction built for demanding industrial environments.
- Flexible wiring options: plug-and-play accessories or hard-wired terminal blocks.
- Integrated on/off switch with optional remote door switch compatibility for enhanced control.
- Black composite end caps and mounting tabs
- Mounting hardware is included
Specifications
Accessory Type | Lighting |
Amps | .26 A |
Application | Controls and Drives; Power Distribution |
Color | Black |
Connection Type | Plug-and-play or Terminal Blocks |
Finish | Smooth Matte |
Hertz | 50/60 Hz |
Material | Plastic |
Modification Services | No |
Mounting Type | Mounting tabs |
Product Family | PaneLite |
Replacement Bulb | F14T5 |
Replacement Lens Cover | LFL28 |
Size | 28-in |
Type | Electrical Accessories |
Voltage AC | 120 V |
Voltage Rating | 120 V |
Weight | 2.6 lb |
Package Dimensions (L x W x H) | 30 IN x 4.8 IN x 2.5 IN |
Package Dimensions (L x W x H) | 76.2 cm x 12.192 cm x 6.35 cm |
Package Weight (Imperial) | 2.600 L |
Package Weight (Metric) | 1.179 kg |

ALF15M18
Light Pkg.Fluorescent, Man Sw, Bulletin A80LT (Light kits - Lighting Packages), Size/Dims: 18.88x 115v/50Hz, Material: Aluminum, Finish:How to Install the Hoffman Fluorescent Lighting Package
This guide provides instructions for safely installing and wiring the Hoffman Fluorescent Lighting Package within an enclosure. Ensure compliance with all applicable national and local electrical codes.
Estimated time: 30m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting hardware, Wire connectors
- Disconnect Power and Review Safety Warnings
WARNING: To avoid electric shock and equipment damage, disconnect all power supplies to the enclosure before beginning installation. Read all instructions carefully before proceeding. Ensure the installation location is not hazardous or wet.
- Mount the Fluorescent Fixture
Mount the fluorescent lighting fixture securely within the enclosure using the appropriate method (e.g., PROLINE frame, enclosure top, channel, or optional panel mounting). Ensure the fixture is firmly attached and level.
- Connect Power and Ground Wiring
Connect the fluorescent fixture to a single-phase power supply consistent with the voltage and frequency found on the product label. Route supply wires away from door hinges and sharp edges. Connect the fluorescent fixture ground terminal to a proper earth ground source. Power must be connected to the switch end of the light. All wiring must comply with applicable national and local electrical codes.
- Install Hard Wiring Component (If Applicable)
If hard wiring, install the necessary component (referred to as 'Item X' in the documentation) after the light is mounted. This step is not required when using power ganging accessory cables.
- Verify Installation and Energize
WARNING: Before energizing any circuits, check all internal and external electrical and mechanical clearances to ensure that all assembled equipment functions safely and properly. Once verified, restore power to the enclosure.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.