Authorized nVent Distributor
nVent LC02-316 - Lifting Devices, LC, 60x100x40mm, Stainless Steel 316

nVent LC02-316 Lifting Devices, LC, 60x100x40mm, Stainless Steel 316

UPC: 783510484224


Documents & Media
Installation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent LC02-316 Lifting Device (SKU: LC02-316) is a precision-engineered component for the safe and efficient handling of bayed, floor-standing enclosures. Constructed from high-grade Stainless Steel 316L, this lifting device delivers exceptional corrosion resistance and durability, making it ideal for harsh industrial environments. Measuring 60x100x40mm, the LC02-316 is designed for direct mounting to the enclosure frame, ensuring load distribution and preventing stress on connected components like top cable frames (e.g., MCU models). This design principle enhances the integrity of the entire enclosure system during installation and maintenance. The device is specifically optimized for 200mm high MCUs, integrating seamlessly with nVent HOFFMAN enclosure systems. Manufactured by nVent, a globally recognized leader in electrical enclosure solutions, the LC02-316 meets rigorous quality standards and is part of a comprehensive range of lifting solutions, including lifting kits (MCUK) and lifting eye bolts (LE). For applications requiring 300mm high MCUs, separate lifting procedures are required.
  • Description: For optimal weight distribution when lifting bayed enclosures. To be used in combination with baying bracket.
  • Pack quantity: 2 pieces with mounting accessories.
  • Advantage: lifting device ensuring optimal distribution of forces when lifting bayed enclosures
  • Benefit: bayed floor standing enclosures can be lifted safely
  • Part of nVent HOFFMAN lifting solution range

Specifications

Application
Controls and Drives; Factory Automation and Process Control
Application
Controls and Drives;Factory Automation and Process Control;Oil and Gas;Power Distribution
Application
Power Distribution; Controls and Drives; Factory Automation and Process Control; Oil and Gas
Color
Unpainted
Consist of
Lifting Devices;Mounting Components and Instruction Manual
Consist of
Lifting Devices; Mounting Components and Instruction Manual
Construction
7 gauge
Depth
40 mm
Depth
1.57 in
Enclosure Material
Mild Steel
Finish
Brushed
Height
2.36 in
Height
60 mm
Material
Stainless Steel 316
Package Quantity
2
Product Family
Free-Standing
Size
2.36 x 3.94 x 1.57 inch
Thickness
51.40mm (2.024")
Thickness
5 mm
Thickness
7 ga
Type
Lifting
Type
IEC Enclosure Accessories
Weight
1.76 lb
Weight
0.14 kg
Weight
32 lbs./100ft
Width
100 mm
Width
3.94 in
Works With
IEC
Package Dimensions (L x W x H)
0.1 IN x 0.1 IN x 0.1 IN
Package Dimensions (L x W x H)
0.254 cm x 0.254 cm x 0.254 cm
Package Weight (Imperial)
0.500 L
Package Weight (Metric)
0.227 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht

EP3030

Eclipse Inner Panel - Fits Encl. 30 x 30 - Steel/Wht
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
External operation handle 0-1 type S3 Black IP65

14333111

External operation handle 0-1 type S3 Black IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the LC02-316 Floor Standing Enclosure

Instructions for mounting and assembling the LC02-316 floor standing enclosure, including door and panel installation.

Estimated time: 2h

Tools needed:

T30 screwdriver, T25 screwdriver, SW13 screwdriver, SW10 screwdriver, SW19 screwdriver, SW3 screwdriver, Torque wrench

Supplies needed:

Mounting screws (M5x10, M6x10, M6x12, M12x20, M8x16, M8x40), Cage nuts, Gasket, Metal guider, Lift handle, Standard locking system, Lift handle locking system, Back panel, Bottom plate, Mounting plate, Brackets

  1. Prepare the enclosure components

    Identify and gather all enclosure parts including side panels, rear panel, bottom plate, roof plate, and mounting plate. Refer to the parts list and diagrams for correct identification. Ensure all necessary hardware, such as screws and cage nuts, are available.

  2. Assemble the main enclosure frame

    Assemble the side panels, rear panel, and bottom plate according to the diagrams. Use the specified screws (e.g., M5x10, M6x10) and tighten them to the recommended torque values. For larger enclosures, ensure the appropriate mounting plates are installed.

  3. Install the roof plate

    Attach the roof plate to the assembled enclosure frame using the designated screws. Ensure a secure fit and proper alignment. For enclosures over 800mm deep, additional steps for mounting plate installation may be required.

  4. Mount the door

    Install the door using the provided hinges and mounting hardware. If using a lift handle locking system, assemble and attach it according to the instructions. Adjust the door for proper alignment and closure. For specific door types like CCM, CCE/CCI, or LE 9304, follow the detailed mounting steps.

  5. Install internal components

    Mount the back panel and any internal mounting plates or guiders as per the diagrams. Use the specified screws and tighten them to the recommended torque values. Ensure all components are securely fastened.

  6. Attach the bottom plate

    Secure the bottom plate to the enclosure base using the provided M8x16 screws. Tighten to the specified torque of 10-15 Nm. Ensure the plate is correctly oriented for bottom entry or exit of cables.

  7. Perform final checks and adjustments

    Verify that all screws are tightened to the correct torque specifications. Check the door alignment and ensure it opens and closes smoothly. Confirm that all panels are securely in place and the enclosure is stable. For enclosures with specific depth or width, refer to the notes regarding additional hardware or steps.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.