Authorized nVent Distributor
nVent LC02 - Lifting Devices, LC, 60x100x40mm, Zinc Plated, Mild Steel

nVent LC02 Lifting Devices, LC, 60x100x40mm, Zinc Plated, Mild Steel

UPC: 783510484170


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent LC02 Lifting Device (SKU LC02) is engineered for the safe and efficient handling of bayed, floor-standing enclosures. Constructed from mild steel with a durable zinc-plated finish, this device offers excellent corrosion resistance for industrial applications. Each pack includes two lifting devices and necessary mounting accessories, ensuring straightforward installation. The dimensions of 60x100x40mm are optimized for compatibility with nVent HOFFMAN bayed enclosure systems. Designed to mount directly into the enclosure's frame, the LC02 effectively distributes lifting loads, preventing strain on other components like top cable frames. This is particularly beneficial when lifting enclosures with 200 mm high MCUs, as it releases the MCU from strain. Note: 300 mm high MCUs must be lifted separately. The LC02 lifting devices comply with DIN 580 lifting requirements when used correctly. For enhanced safety and structural integrity during enclosure installation and maintenance, the nVent LC02 provides a reliable lifting point. It is part of a comprehensive suite of nVent HOFFMAN lifting solutions, complementing items like the MCUK Lifting Kit and LE Lifting Eye Bolts. Always adhere to nVent HOFFMAN's lifting instructions for safe operation.
  • Description: For optimal weight distribution when lifting bayed enclosures. To be used in combination with baying bracket.
  • Pack quantity: 2 pieces with mounting accessories.
  • Advantage: lifting device ensuring optimal distribution of forces when lifting bayed enclosures
  • Benefit: bayed floor standing enclosures can be lifted safely
  • Includes 2 devices and mounting accessories, compliant with DIN 580

Specifications

Application
Controls and Drives;Factory Automation and Process Control;Oil and Gas;Power Distribution
Application
Factory Automation and Process Control; Controls and Drives; Power Distribution; Oil and Gas
Application
Factory Automation and Process Control; Controls and Drives
Color
Unpainted
Consist of
Lifting Devices;Mounting Components and Instruction Manual
Consist of
Lifting Devices; Mounting Components and Instruction Manual
Construction
7 gauge
Depth
40 mm
Depth
1.57 in
Enclosure Material
Mild Steel
Finish
Zinc Plated
Height
2.36 in
Height
60 mm
Material
Mild Steel
Package Quantity
2
Product Family
Free-Standing
Size
2.36 x 3.94 x 1.57 inch
Thickness
51.40mm (2.024")
Thickness
5 mm
Thickness
7 ga
Type
Lifting
Type
IEC Enclosure Accessories
Weight
0.8 kg
Weight
1.76 lb
Weight
32 lbs./100ft
Width
100 mm
Width
3.94 in
Works With
IEC
Package Dimensions (L x W x H)
8 IN x 6 IN x 6 IN
Package Dimensions (L x W x H)
20.32 cm x 15.24 cm x 15.24 cm
Package Weight (Imperial)
1.760 L
Package Weight (Metric)
0.798 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What is the LC02 lifting device made of?

The LC02 lifting device is made of mild steel with a zinc-plated finish.

What are the dimensions of the LC02 lifting device?

The LC02 lifting device has dimensions of 2.36 inches in height, 3.94 inches in width, and 1.57 inches in depth.

How much does the LC02 lifting device weigh?

The LC02 lifting device weighs 1.76lb.

What is the pack quantity for the LC02 lifting device?

The LC02 lifting device comes in a pack quantity of 2 pieces with mounting accessories.

What is the purpose of the LC02 lifting device?

The LC02 lifting device is used for optimal weight distribution when lifting bayed floor standing enclosures.

What is the thickness of the LC02 lifting device?

The thickness of the LC02 lifting device is 7ga.

What must be used in combination with the LC02 lifting device?

The LC02 lifting device must be used in combination with a baying bracket.

How to Install the LC02 Enclosure

This guide provides step-by-step instructions for mounting and wiring the LC02 enclosure safely and effectively.

Estimated time: 1h

Tools needed:

Screwdriver, Torque wrench, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Cage nuts, Wire connectors

  1. Prepare the mounting surface

    Ensure the mounting surface is clean and level. If mounting on a combustible surface, install a floor plate of at least 1.43 mm galvanized or 1.6 mm uncoated steel, extending at least 150 mm beyond the enclosure on all sides.

  2. Mount the enclosure

    Secure the LC02 enclosure to the mounting surface using the provided mounting screws and cage nuts. Ensure the enclosure is level and firmly attached.

  3. Connect the wiring

    Strip the ends of the wires and connect them to the appropriate terminals inside the enclosure. Use wire connectors to secure the connections.

  4. Verify electrical connections

    Use a multimeter to check the continuity of the connections. Ensure there are no short circuits and that all connections are secure.

  5. Calibrate the enclosure

    Adjust any necessary settings on the enclosure according to the manufacturer's specifications. Ensure all components are functioning correctly before closing the enclosure.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.