Authorized nVent Distributor
nVent HIBMX2CWCL - Hazloc Cable Glands for Non Armored Cable, Non-Metallic (Ex e/tb), M20x1.5

nVent HIBMX2CWCL Hazloc Cable Glands for Non Armored Cable, Non-Metallic (Ex e/tb), M20x1.5

UPC: 783510306977


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Ensure the utmost safety and reliability in hazardous environments with the nVent HIBMX2CWCL Hazloc Cable Gland. Engineered for non-armored cables, this M20x1.5 threaded gland is specifically designed for increased safety (Ex e) and dust (Ex tb) applications, making it an indispensable component for protecting critical processes and personnel. It provides essential strain relief, robust sealing, and secure cable entry into enclosures and electrical equipment where explosive gas and dust may be present. Certified for use in Zone 1, 2, 21, and 22, this cable gland carries ATEX and IEC certifications, underscoring its suitability for the most demanding industrial settings. The nVent HIBMX2CWCL is constructed from durable nickel-plated brass with a chloroprene seal, offering an operating temperature range of -40°C to 100°C (-40°F to 212°F). For applications requiring a wider temperature tolerance, a 316L stainless steel variant with a silicone seal is also available, extending the operating range to -60°C to 130°C (-76°F to 266°F). Key features of the nVent HIBMX2CWCL include: * **Versatile Application:** Suitable for non-armored cables in Ex e and Ex tb environments. * **Enhanced Sealing:** Designed with three levels of removable seals to accommodate a wider clamping range and ensure effective protection against ingress. * **Complete Kit:** All metric thread cable glands, including this M20x1.5 model, are supplied as comprehensive kits. Each kit contains a chloroprene washer, a locknut, and an earth tag, simplifying installation and ensuring all necessary components are present. * **Robust Construction:** Available in nickel-plated brass with a chloroprene seal, providing excellent durability and resistance to environmental factors. * **Wide Temperature Tolerance:** Operates reliably within a broad temperature spectrum, ensuring performance across various conditions. This cable gland is ideal for a multitude of applications within industries such as oil and gas, chemical processing, pharmaceuticals, mining, and any sector where hazardous atmospheres are a concern. The nVent brand is synonymous with quality and innovation in electrical protection solutions, and the HIBMX2CWCL is a testament to their commitment to safety and performance. Its design facilitates a secure and compliant installation, minimizing the risk of equipment failure or safety incidents. Professionals rely on nVent cable glands for their consistent performance, ease of installation, and adherence to stringent international safety standards. The M20x1.5 thread size is a common standard, ensuring compatibility with a wide array of enclosures and equipment.
  • Suitable for non-armored cables in increased safety (ex e) and dust (ex tb) applications
  • Provide high level of protection and reliability in extreme environments with impact resistance of up to 7 Joules
  • All metric thread cable glands are packaged as kits
  • Each kit includes a chloroprene washer, a locknut and an earthtag
  • Includes chloroprene seal
  • Available in Metric (M) and NPT (N) thread type
  • Operating temperature from -40 C to 70 C with chloroprene seal

Specifications

Application
Hazardous Environments
Clamping Range
0.28-0.47 in
Clamping Range Diameter
0.28-0.47 in
Clamping Range Diameter
7.0-12.0 mm
Color
Dark Gray
Color
Gray
Finish
Smooth Matte
IP Rating
IP66/68 (EN60529)
Material
Polyamide 6
Min H
23 mm
Min H
2,600 mm
Seal
Chloroprene
Size
M20x1.5
Type
Other Accessories
Weight
0.1 lb
Works With
NEMA / IEC
Package Dimensions (L x W x H)
6 IN x 6 IN x 1 IN
Package Dimensions (L x W x H)
15.24 cm x 15.24 cm x 2.54 cm
Package Weight (Imperial)
0.100 L
Package Weight (Metric)
0.045 kg
Hazloc Cable Glands for Non Armored Cable, Non-Metallic (Ex e/tb), NPT3/8"

HIBNX1C

Hazloc Cable Glands for Non Armored Cable, Non-Metallic (Ex e/tb), NPT3/8"
Sealing plug for cover screw ? Grey

DP 14553

Sealing plug for cover screw ? Grey
cordgrip - black nylon. Mounting hole diameter 1.115"

1427CG21

cordgrip - black nylon. Mounting hole diameter 1.115"
Non-metallic Nylon Clamp, 3/16 Inch, White. Screw Hole Size .203 for #10 Screw. Temperature Range -40 Degrees F to 176 Degrees F. 100 per Box

12-103

Non-metallic Nylon Clamp, 3/16 Inch, White. Screw Hole Size .203 for #10 Screw. Temperature Range -40 Degrees F to 176 Degrees F. 100 per Box
6x6x3 Polycarbonate Enclosure NEMA 6P | Standard Hinge | Clear Lid | Integrated Locking Latch | Intergrated Mounting Flange

P6063C

6x6x3 Polycarbonate Enclosure NEMA 6P | Standard Hinge | Clear Lid | Integrated Locking Latch | Intergrated Mounting Flange
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder

AB763

The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack

SBL300

Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack
TOUCH-UP PAINT BRUSH COLOR RAL7035 FOR CADRYS DELTA

51900000

TOUCH-UP PAINT BRUSH COLOR RAL7035 FOR CADRYS DELTA
A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.

RCR75J

A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.

How to Install the HIBMX2CWCL Controller

This guide provides step-by-step instructions for installing and configuring the HIBMX2CWCL controller, ensuring proper wiring and calibration for optimal performance.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the HIBMX2CWCL controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the power supply

    Using wire strippers, prepare the power supply cables and connect them to the designated terminals on the controller. Ensure all connections are tight and secure.

  3. Wire the input/output connections

    Connect the input and output wires to the corresponding terminals on the controller. Verify the wiring against the provided schematic to ensure correct connections.

  4. Configure the controller settings

    Power on the controller and use the interface to configure the necessary settings, including operational parameters and communication protocols.

  5. Calibrate the controller

    Perform calibration by following the on-screen instructions. Use a multimeter to verify output signals and adjust settings as necessary for accuracy.

  6. Verify installation

    After completing the installation and configuration, conduct a final check to ensure all connections are secure and the controller operates as intended.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.