Contact for Pricing
Overview
- Suitable for non-armored cables in increased safety (ex e) and dust (ex tb) applications
- Provide high level of protection and reliability in extreme environments with impact resistance of up to 7 Joules
- All metric thread cable glands are packaged as kits
- Each kit includes a chloroprene washer, a locknut and an earthtag
- Includes chloroprene seal
- Available in Metric (M) and NPT (N) thread type
- Operating temperature from -40 C to 70 C with chloroprene seal
Specifications
Application | Hazardous Environments |
Clamping Range | 0.24-0.39 in |
Clamping Range Diameter | 6.0-10.0 mm |
Clamping Range Diameter | 0.24-0.39 in |
Color | Dark Gray |
Color | Gray |
Finish | Smooth Matte |
IP Rating | IP66/68 (EN60529) |
Material | Polyamide 6 |
Min H | 2,600 mm |
Min H | 21.5 mm |
Seal | Chloroprene |
Size | M16x1.5 |
Thread Size | M16 x 1.5 |
Type | Other Accessories |
Weight | 0.1 lb |
Works With | NEMA / IEC |
Package Dimensions (L x W x H) | 6 IN x 6 IN x 0.75 IN |
Package Dimensions (L x W x H) | 15.24 cm x 15.24 cm x 1.905 cm |
Package Weight (Imperial) | 0.100 L |
Package Weight (Metric) | 0.045 kg |

P6063C
6x6x3 Polycarbonate Enclosure NEMA 6P | Standard Hinge | Clear Lid | Integrated Locking Latch | Intergrated Mounting Flange
AB253
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
RCR75J
A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.How to Install the HIBMX1CWCL Controller
This guide provides step-by-step instructions for installing and configuring the HIBMX1CWCL controller, ensuring proper wiring and calibration for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the HIBMX1CWCL controller to the designated mounting surface using the provided mounting screws. Ensure that the controller is level and securely fastened.
- Connect the wiring
Lead the appropriate cables through the cable glands and connect them to the terminal connectors on the controller. Make sure to tighten the cable glands to ensure a watertight seal.
- Power on and configure
Turn on the power supply to the controller. Use a multimeter to verify that the voltage levels are correct. Follow the manufacturer's instructions to configure the controller settings as needed.
- Calibrate the controller
Perform any necessary calibration procedures as specified in the user manual. This may include adjusting settings based on the specific application requirements.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.