Contact for Pricing
Overview
- Hinge allows the shroud to be opened at a 45-degree angle for easy filter replacement
- Hinge design also allows for easy and complete removal for cleaning
- 10-degree, sloped top design
- Only reduces filter fan airflow by 10 percent
- FDA approved blue silicone gasket that is easily replaceable
- Pre-drilled side holes allow for locking provision on side
- FDA approved blue silicone gasket that is easily replaceable
- Pre-drilled side holes allow for locking provision on side
Specifications
Application | Controls and Drives;Power Distribution |
Color | Light Gray |
Color | Gray |
Color | Grey |
Color Code | RAL 7035 |
Depth | 6.1 in |
Depth | 155 mm |
Finish | Powder Coated |
Height | 495 mm |
Height | 19.5 in |
Material | Mild Steel |
Protection Rating | NEMA Type 4 |
Thickness | 16 ga |
Thickness | 1.52 mm |
Thickness | 51.40mm (2.024") |
Type | Fans and Filter Fans |
Weight | 21 lb |
Width | 14.3 in |
Width | 363 mm |
Package Dimensions (L x W x H) | 19.5 IN x 14.34 IN x 21 IN |
Package Dimensions (L x W x H) | 49.53 cm x 36.4236 cm x 53.34 cm |
Package Weight (Imperial) | 21.000 L |
Package Weight (Metric) | 9.526 kg |
How to Install the HH13 Filter Fan Shroud
This guide provides step-by-step instructions for installing the HH13 Filter Fan Shroud to ensure proper ventilation and maintain UL/cUL Type 4/4X rating.
Estimated time: 30m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Prepare the installation area
Ensure the installation area is clean and free of obstructions. Verify that the mounting surface can support the weight of the shroud.
- Mount the shroud
Secure the HH13 Filter Fan Shroud to the designated mounting surface using the provided mounting screws. Ensure it is level and tightly fastened.
- Connect the wiring
Use wire strippers to prepare the wires and connect them to the appropriate terminals on the fan. Ensure all connections are secure to prevent any electrical issues.
- Verify the installation
After installation, check that the shroud is properly mounted and that all electrical connections are secure. Use a multimeter to test for continuity.
- Calibrate the system
Turn on the system and monitor the fan operation. Adjust settings as necessary to ensure optimal performance.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.