nVent G572026G360 SpectraCool Advanced Corrosion Protection Lvl 1 with RAC, 20000BTU 230V, Lt Gray, Steel
UPC: 783510356941
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Attractive industrial design with minimal use of visible fasteners
- Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
- Energy-efficient rotary compressor on most models
- Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing ) side and an additional wrap around the thermostat
- Cleanable, reusable aluminum mesh filter included to protect coils for maximum cooling performance in dirty environments
- Reliable mechanical thermostat on enclosure side of the unit
- All G-series come standard with two separate thermostats for cooling and heating when a heater is equipped
- Operating temperature range from -40 F/-40 C to 131 F/55 C
- Dust-resistant condenser coil allows the unit to be run filterless in most indoor applications
- Dual condenser-side air movers for performance redundancy on G52 and G57 models
Specifications
Ambient Temperature | 40 Deg C |
Ambient Temperature | -40-131 °F |
Application | Controls and Drives;Corrosive Environments;Power Distribution |
Application | Corrosive Environments; Power Distribution; Controls and Drives |
Color | Light Gray |
Color | Gray |
Color Code | RAL 7035 |
Corrosion Resistant | Yes |
Depth | 15.28 in |
Depth | 388 mm |
Finish | Powder Coated |
Height | 57.69 in |
Height | 1,465 mm |
Material | Mild Steel |
Max Current | 22.2 A |
Mounting | Side wall |
NEMA Rating | 4X Watertight, corrosion-resistant |
Nominal Capacity Btu/h | 20,000 Btu/h |
Nominal Capacity Watts | 5,861 W |
Nominal Voltage | 230 V |
Number Of Phases | 1 |
Operating Temperature | -40-55 °C |
Operating Temperature | -40-131 °F |
Operating Temperature | -40-55 |
Outdoor Installation | Yes |
Product Family | SpectraCool |
Protection Rating | NEMA Type 4X |
Refrigerant | R407C |
Remote Access Control | Yes |
Thickness | 1.21 mm |
Thickness | 18 ga |
Thickness | 51.40mm (2.024") |
Type | Air Conditioners |
Voltage AC | 200-250 V |
Weight | 225 lb |
Weight | 89 kg |
Width | 530 mm |
Width | 20.87 in |
Package Dimensions (L x W x H) | 57.7 IN x 20.89 IN x 15.36 IN |
Package Dimensions (L x W x H) | 146.558 cm x 53.0606 cm x 39.0144 cm |
Package Weight (Imperial) | 225.000 L |
Package Weight (Metric) | 102.060 kg |
How to Install the G572026G360 Air Conditioner
Installation guide for mounting and wiring the G572026G360 SPECTRACOOL Air Conditioner.
Estimated time: 45m
Tools needed:
Wrench, Ratchet driver, Screwdriver
Supplies needed:
Mounting gasket kit, Copper conductors
- Inspect and Test the Air Conditioner
Inspect the air conditioner for any damage that may have occurred during shipment. If the unit has been in a horizontal position, ensure it is placed upright for a minimum of five (5) minutes before operating. Test the unit's functionality before mounting it to the enclosure. Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply using copper conductors only. The minimum circuit ampacity should be at least 125% of the amperage shown on the unit nameplate. Immediately after applying power, the evaporator blower should start. Operate the air conditioner with the compressor running for five to ten minutes by setting the cooling thermostat or controller setpoint below the ambient temperature. Condenser air temperatures should become warmer than normal room temperatures within a few minutes after the condenser impellers start. WARNING: Do not operate the air conditioner while it is horizontal or on its side, back, or front, as this can cause permanent damage and void the warranty.
- Mount the Air Conditioner
Install the provided mounting gasket kit to the air conditioner. Mount the air conditioner onto the enclosure, taking care not to damage the gasket. Start mounting bolts by hand to avoid cross-threading before tightening with a wrench or ratchet driver. Ensure the air conditioner remains in an upright position during operation.
- Wire the Air Conditioner
Refer to the unit's nameplate for specific electrical requirements. Wire the unit to a properly grounded power supply using copper conductors. For 3-phase units, after applying power, verify that the phase monitor light is illuminated, indicating correct electrical phasing. The electrical circuit should be fused with a slow-blow or HACR circuit breaker. If the unit requires a remote-mounted thermostat, wire the thermostat outputs to the appropriate terminals on the 24 VAC terminal strip according to the correct wiring diagram.
- Set Thermostat
Set the thermostat to the required cabinet temperature. Refer to the 'Sequence of Operation' section for thermostat adjustment and operation details. Note: For testing purposes only, the thermostat stop screw may be removed to allow settings below 70 F. After testing, replace the stop screw and verify that the thermostat cannot be set below 70 F. Extended operation below 70 F can cause coil freeze-ups, reduced load, or unit damage.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.