nVent G521246G151 SpectraCool Outdoor with Heat G52, 12000BTU 460V, Brushed, SS304
UPC: 783510211738
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Attractive industrial design with minimal use of visible fasteners
- Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
- Energy-efficient rotary compressor on most models
- Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing ) side and an additional wrap around the thermostat
- Cleanable, reusable aluminum mesh filter included to protect coils for maximum cooling performance in dirty environments
- Reliable mechanical thermostat on enclosure side of the unit
- All G-series come standard with two separate thermostats for cooling and heating when a heater is equipped
- Operating temperature range from -40 F/-40 C to 131 F/55 C
- Dust-resistant condenser coil allows the unit to be run filterless in most indoor applications
- Dual condenser-side air movers for performance redundancy on G52 and G57 models
Specifications
Ambient Temperature | -40-131 °F |
Ambient Temperature | 40 Deg C |
Application | Power Distribution; Controls and Drives; Corrosive Environments |
Application | Controls and Drives;Corrosive Environments;Power Distribution |
Color | Unpainted |
Corrosion Resistant | No |
Depth | 296 mm |
Depth | 11.66 in |
Finish | Brushed #3 |
Height | 1,338 mm |
Height | 52.69 in |
Material | Stainless Steel 304 |
Max Current | 3.5 A |
Mounting | Side wall |
NEMA Rating | 4X Watertight, corrosion-resistant |
Nominal Capacity Btu/h | 12,000 Btu/h |
Nominal Capacity Watts | 3,500 W |
Nominal Voltage | 460 V |
Number Of Phases | 3 |
Operating Temperature | -40-55 |
Operating Temperature | -40-55 °C |
Operating Temperature | -40-131 °F |
Outdoor Installation | Yes |
Product Family | SpectraCool |
Protection Rating | NEMA Type 4X |
Refrigerant | R513A |
Remote Access Control | No |
Thickness | 51.40mm (2.024") |
Thickness | 20 ga |
Type | Air Conditioners |
Voltage AC | 400-460 V |
Weight | 64 kg |
Weight | 165 lb |
Width | 435 mm |
Width | 17.12 in |
Package Dimensions (L x W x H) | 19 IN x 16 IN x 55 IN |
Package Dimensions (L x W x H) | 48.26 cm x 40.64 cm x 139.7 cm |
Package Weight (Imperial) | 165.000 L |
Package Weight (Metric) | 74.844 kg |

WCHESOLVLV05230VSP
SOLENOID VALVE 5 NC 220VAC, Bulletin MCLHE (Heat exchangers - A2W Heat Exchanger), Material: Steel
WCHEFANCAP2MFDSP
CAP 2µF 400V 4 16 33 63 29, Bulletin MCLHE (Heat exchangers - A2W Heat Exchanger), Material: Steel
WCHE149FAN230VSP
FAN EBM 230V 1 50 60Hz, Bulletin MCLHE (Heat exchangers - A2W Heat Exchanger), Material: Steel ex3How to Install the G521246G151 SPECTRACOOL Air Conditioner
Installation guide for mounting and wiring the G521246G151 SPECTRACOOL Air Conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wrench, Ratchet driver
Supplies needed:
Mounting gasket kit, Copper conductors, Slow blow or HACR circuit breaker
- Test Functionality
Inspect the air conditioner and verify correct functionality before mounting. If the unit has been in a horizontal position, ensure it remains upright for at least five (5) minutes before operating. Do not operate the unit while it is horizontal or on its side, back, or front, as this can cause permanent damage and void the warranty. Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply using only copper conductors. The minimum circuit ampacity should be at least 125% of the amperage shown on the unit nameplate. No other equipment should be connected to this circuit. Immediately after applying power, the evaporator blower should start. Operate the air conditioner with the compressor running for five (5) to ten (10) minutes by setting the cooling thermostat or controller setpoint below the ambient temperature. Condenser air temperatures should become warmer than normal room temperatures within a few minutes after the condenser impellers start.
- Install Mounting Gasket
Using the provided mounting gasket kit, install the gaskets to the air conditioner according to Figure 1.
- Mount the Air Conditioner
Mount the air conditioner onto the enclosure, taking care not to damage the mounting gasket, which provides the seal between the unit and the enclosure. Avoid dragging the air conditioner on the enclosure with the gasket attached to prevent rips or tears. Start mounting bolts by hand before tightening with a wrench or ratchet driver to avoid cross-threading.
- Connect Power Supply
Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply. The unit's terminal block is located behind the evaporator access panel on the rear (enclosure side) of the unit. For 3-phase units, after applying power, verify that the phase monitor light is illuminated, indicating correct electrical phasing. The electrical circuit should be fused with a slow blow or HACR circuit breaker.
- Set Thermostat or Controller
If the air conditioner requires a remote-mounted thermostat, wire the thermostat outputs to the appropriate terminals on the 24 VAC terminal strip, referencing the correct wiring diagram. Set the thermostat or controller setpoints for the required cabinet temperature. Refer to the Sequence of Operation on page 4 for thermostat adjustment and operation, or page 15 for controller setpoint adjustment and operation. Note that the thermostat dial may be protected by a plastic bushing during shipment; remove and replace it to adjust the thermostat. Do not set the enclosure thermostat to a temperature lower than 70 F for normal operation, as this can cause coil freeze-ups.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.