nVent G520846G360 SpectraCool Advanced Corrosion Protection Lvl 1 with RAC, 8000BTU 460V, Lt Gray, Steel
UPC: 783510356736
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Attractive industrial design with minimal use of visible fasteners
- Advanced Corrosion Protection Level 1 (ACP L1) Protection Includes: Protective coatings only applied to copper tubing and coils on the condenser (exterior facing) side as well as thermostat coatings
- Energy-efficient rotary compressor on most models
- Advanced Corrosion Protection Level 2 (ACP L2) Protection Includes: Everything that was coated in ACP L1, plus protective coatings applied to the evaporator (interior facing ) side and an additional wrap around the thermostat
- Cleanable, reusable aluminum mesh filter included to protect coils for maximum cooling performance in dirty environments
- Reliable mechanical thermostat on enclosure side of the unit
- All G-series come standard with two separate thermostats for cooling and heating when a heater is equipped
- Operating temperature range from -40 F/-40 C to 131 F/55 C
- Dust-resistant condenser coil allows the unit to be run filterless in most indoor applications
- Dual condenser-side air movers for performance redundancy on G52 and G57 models
Specifications
Ambient Temperature | 40 Deg C |
Ambient Temperature | -40-131 °F |
Application | Controls and Drives;Corrosive Environments;Power Distribution |
Color | Gray |
Color | Lt Gray |
Color | Light Gray |
Color Code | RAL 7035 |
Corrosion Resistant | Yes |
Depth | 11.66 in |
Depth | 296 mm |
Finish | Powder Coated |
Height | 1,338 mm |
Height | 52.69 in |
Material | Mild Steel |
Material | Steel |
Max Current | 3.2 A |
Mounting | Side wall |
NEMA Rating | 4X Watertight, corrosion-resistant |
Nominal Capacity Btu/h | 8,000 Btu/h |
Nominal Capacity Watts | 3,500 W |
Nominal Voltage | 460 V |
Number Of Phases | 3 |
Operating Temperature | -40-131 °F |
Operating Temperature | -40-55 °C |
Operating Temperature | -40-55 |
Outdoor Installation | Yes |
Poles | 3P |
Product Family | SpectraCool |
Protection Rating | NEMA Type 4X |
Refrigerant | R513A |
Remote Access Control | Yes |
Series | SpectraCool |
Size | 8000BTU |
Thickness | 1.21 mm |
Thickness | 18 ga |
Thickness | 51.40mm (2.024") |
Type | Air Conditioners |
Voltage AC | 400-460 V |
Voltage Rating | 460 V |
Weight | 62.6 kg |
Weight | 128 lb |
Width | 17.12 in |
Width | 435 mm |
Package Dimensions (L x W x H) | 52.7 IN x 17.14 IN x 11.65 IN |
Package Dimensions (L x W x H) | 133.858 cm x 43.5356 cm x 29.591 cm |
Package Weight (Imperial) | 128.000 L |
Package Weight (Metric) | 58.061 kg |

N280426G219
The nVent N280426G219 industrial electrical connector is a rugged, high-reliability solution designed for professionals who demand precision and durability in harsh operating conditions. Manufactured by nVent, a global leader in electrical and thermal management solutions, this connector delivers superior performance in applications where environmental resilience and electrical integrity are critical. Engineered to meet the demands of industrial automation, power distribution, and heavy machinery, the N280426G219 ensures consistent connectivity in environments subject to vibration, moisture, dust, and extreme temperatures. Its robust construction and compliance with industry standards make it an ideal choice for engineers and technicians seeking a dependable connection solution. This connector is part of nVent’s trusted portfolio of electrical components, which are trusted by industries such as oil and gas, mining, manufacturing, and utilities. The N280426G219 is particularly well-suited for use in control panels, motor starters, and field wiring applications where reliable signal and power transmission are essential. Its design incorporates features that simplify installation and maintenance, including secure locking mechanisms and corrosion-resistant materials, ensuring long-term operation with minimal downtime. Professionals in the field appreciate the connector’s compatibility with a wide range of wire gauges and its ability to maintain low contact resistance over time, reducing the risk of electrical failures. Key applications for the nVent N280426G219 include: - Industrial automation and control systems - Power distribution in commercial and industrial facilities - Heavy machinery and equipment wiring - Harsh environment installations, such as outdoor or underground settings - Renewable energy systems, including solar and wind power installations When selecting an industrial connector, factors such as environmental ratings (IP67, IP68, or NEMA 4X compliance), material durability, and ease of installation are paramount. The N280426G219 excels in these areas, offering a combination of high-quality materials, such as nickel-plated copper contacts and ruggedized housings, to withstand the rigors of industrial use. Its compact design allows for efficient use of space in crowded control panels, while its vibration-resistant features ensure stable performance even in high-motion environments. nVent’s reputation for innovation and quality is underscored by its adherence to rigorous testing standards, including UL, CSA, and IEC certifications. The N280426G219 connector is no exception, having been subjected to extensive validation to ensure it meets the highest standards of safety and performance. For professionals who prioritize reliability, longevity, and ease of use, the nVent N280426G219 is a standout choice that delivers on all fronts. Whether you’re retrofitting existing systems or designing new installations, this connector provides the confidence you need to keep your operations running smoothly, no matter the conditions.
N170216G222
The nVent N170216G222 industrial cable gland is a robust, UL-listed solution designed for secure cable entry and sealing in demanding industrial environments. Engineered by nVent, a global leader in electrical and thermal management solutions, this cable gland ensures reliable performance in applications where moisture, dust, vibration, and mechanical stress are common concerns. Built to meet stringent industry standards, the N170216G222 provides a durable barrier against environmental contaminants while maintaining cable integrity, making it an essential component for electrical installations in manufacturing, oil & gas, chemical processing, and infrastructure projects. This heavy-duty cable gland features a corrosion-resistant nickel-plated brass body, offering exceptional durability and long-term reliability in outdoor and corrosive environments. The integrated sealing system delivers IP68-rated protection, ensuring watertight and dustproof performance even under prolonged exposure to liquids or particulate matter. The gland’s design accommodates a wide range of cable diameters, providing flexibility for retrofitting or new installations where cable size variability is a factor. With a compact yet sturdy construction, the N170216G222 minimizes installation space while maximizing protection, reducing the risk of cable damage or system failure. Professionals in industrial electrical installations rely on nVent cable glands for their proven track record in harsh conditions. The N170216G222 is particularly well-suited for: - **Manufacturing facilities** requiring reliable cable management in production lines. - **Oil & gas and chemical plants** where explosion-proof and corrosion-resistant components are critical. - **Renewable energy projects**, including wind and solar installations, where outdoor durability is paramount. - **Water treatment and wastewater management** systems exposed to high humidity and chemical exposure. - **Transportation infrastructure**, such as rail, road, and tunnel systems, where vibration and mechanical stress demand robust solutions. Installation is straightforward with the N170216G222, thanks to its user-friendly design that includes a pre-assembled sealing nut and a clear cable entry path. The gland’s modular construction allows for quick adjustments to accommodate different cable sizes without the need for specialized tools, reducing downtime during setup. For optimal performance, professionals recommend ensuring proper torque application during installation to maintain the gland’s sealing integrity over time. nVent’s reputation for innovation and quality in electrical protection solutions makes the N170216G222 a trusted choice among engineers and contractors. With a manufacturing origin in the United States, this product adheres to rigorous quality control standards, ensuring consistency and reliability across installations. Whether used in new construction or maintenance projects, the nVent N170216G222 cable gland delivers the durability and performance required to safeguard critical electrical systems in the most challenging conditions.
G280446G226
The nVent G280446G226 is a high-performance industrial component designed for demanding electrical and mechanical applications. Engineered for durability and precision, this product ensures reliable operation in harsh environments. Its robust construction and advanced materials make it ideal for industrial settings where performance and longevity are critical. Trust nVent's expertise in delivering top-tier solutions for your infrastructure needs.How to Install the G520846G360 SPECTRACOOL Air Conditioner
Installation guide for mounting and wiring the G520846G360 SPECTRACOOL Air Conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wrench, Ratchet driver
Supplies needed:
Mounting gasket kit, Copper conductors, Slow blow or HACR circuit breaker
- Test Functionality
Inspect the air conditioner and verify correct functionality before mounting. If the unit has been in a horizontal position, ensure it remains upright for at least five (5) minutes before operating. Do not operate the unit while it is horizontal or on its side, back, or front, as this can cause permanent damage and void the warranty. Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply using only copper conductors. The minimum circuit ampacity should be at least 125% of the amperage shown on the unit nameplate. No other equipment should be connected to this circuit. Immediately after applying power, the evaporator blower should start. Operate the air conditioner with the compressor running for five (5) to ten (10) minutes by setting the cooling thermostat or controller setpoint below the ambient temperature. Condenser air temperatures should become warmer than normal room temperatures within a few minutes after the condenser impellers start.
- Install Mounting Gasket
Using the provided mounting gasket kit, install the gaskets to the air conditioner according to Figure 1.
- Mount the Air Conditioner
Mount the air conditioner onto the enclosure, taking care not to damage the mounting gasket, which provides the seal between the unit and the enclosure. Avoid dragging the air conditioner on the enclosure with the gasket attached to prevent rips or tears. Start mounting bolts by hand before tightening with a wrench or ratchet driver to avoid cross-threading.
- Connect Power Supply
Refer to the nameplate for electrical requirements and wire the unit to a properly grounded power supply. The unit's terminal block is located behind the evaporator access panel on the rear (enclosure side) of the unit. For 3-phase units, after applying power, verify that the phase monitor light is illuminated, indicating correct electrical phasing. The electrical circuit should be fused with a slow blow or HACR circuit breaker.
- Set Thermostat or Controller
If the air conditioner requires a remote-mounted thermostat, wire the thermostat outputs to the appropriate terminals on the 24 VAC terminal strip, referencing the correct wiring diagram. Set the thermostat or controller setpoints for the required cabinet temperature. Refer to the Sequence of Operation on page 4 for thermostat adjustment and operation, or page 15 for controller setpoint adjustment and operation. Note that the thermostat dial may be protected by a plastic bushing during shipment; remove and replace it to adjust the thermostat. Do not set the enclosure thermostat to a temperature lower than 70 F for normal operation, as this can cause coil freeze-ups.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.