Authorized nVent Distributor
nVent F88WE225 - Elbow 22.50-Degree Feed-Through, 8.00x8.00, Gray, Steel

nVent F88WE225 Elbow 22.50-Degree Feed-Through, 8.00x8.00, Gray, Steel

UPC: 783510157708


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent F88WE225 is a 22.5-degree feed-through elbow designed for NEMA Type 12 wireway systems. Constructed from durable steel and finished in a neutral gray, this fitting integrates seamlessly into continuous wireway runs, providing essential protection for electrical conductors in industrial environments. The 8.00x8.00 inch (203x203 mm) dimensions ensure compatibility with standard nVent wireway systems, facilitating efficient installations. This elbow is used between adjacent wireway sections or fittings, enabling gradual, controlled turns to prevent sharp bends that compromise cable performance. Its feed-through design allows for uninterrupted wire and cable runs, simplifying installation and maintenance. The 22.5-degree angle minimizes stress on cables, making it ideal for high-density cabling or sensitive data transmission applications where signal integrity is critical. Key features include robust steel construction for superior mechanical strength and impact resistance, a protective gray finish for corrosion resistance, and precise 8.00x8.00 inch sizing for compatibility with nVent wireway products. This fitting is commonly used in manufacturing plants, processing facilities, and power generation settings to maintain organized and protected cable pathways.
  • Feed-Through 22.50-Degree Elbows are used for continuous runs with 22.50-degree turns
  • Connects to other wireway sections and fittings and protects wires and cables against dust in a broad range of industrial applications
  • Enables gradual turns to prevent cable stress and signal degradation
  • Feed-through design allows continuous wireway runs without interruption
  • Compatible with standard nVent wireway systems for efficient installations

Specifications

Application
Power Distribution
Color
Gray
Color
Grey
Color Code
ANSI 61
Finish
Painted;Powder Coat
Finish
Powder Coated
Height
44 IN
Height
8 in
Height
203.2 mm
Height
203
IP Rating
IP54
Material
Mild Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Protection Rating
NEMA Type 12
Thickness
14 ga
Thickness
1.9 mm
Thickness
51.40mm (2.024")
Type
Elbow;Industrial Feed-Through Wireway
Type
Elbow
Type Number
Type 12
Weight
6.2 lb
Width
8 in
Width
203
Width
23 IN
Wireway
Feed-Through NEMA Type 12 Wireway
Package Dimensions (L x W x H)
10 IN x 8 IN x 10.75 IN
Package Dimensions (L x W x H)
25.4 cm x 20.32 cm x 27.305 cm
Package Weight (Imperial)
6.500 L
Package Weight (Metric)
2.948 kg
Nipple Feed-Through Wireway, 8.00x8.00x6.00, Gray, Mild Steel

F88WN6

Nipple Feed-Through Wireway, 8.00x8.00x6.00, Gray, Mild Steel
Type 3R Wiring Trough - 8x8x36 - Galv/Gray

C3RWT836

Type 3R Wiring Trough - 8x8x36 - Galv/Gray
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BIW10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.
Wire Safe Fitting - 6 inch X 6 Inch External Coupling.

EGCER

Wire Safe Fitting - 6 inch X 6 Inch External Coupling.
Straight Section Feed-Through Type 12 and 3R, 4.00x4.00x36.00, Gray, Fiberglass

F44W36FG

Straight Section Feed-Through Type 12 and 3R, 4.00x4.00x36.00, Gray, Fiberglass
Flexible Fitting Feed-Through, 4.00x4.00, Brushed, SS304, Fits Fiberglass

F44WFFFG

Flexible Fitting Feed-Through, 4.00x4.00, Brushed, SS304, Fits Fiberglass
Wiring Trough NEMA Type 12 and 3R, 6.00x6.00x12.00, Gray, Fiberglass

F6612FG

Wiring Trough NEMA Type 12 and 3R, 6.00x6.00x12.00, Gray, Fiberglass
Elbow 22.50-Degree Feed-Through, 4.00x4.00, Gray, Steel

F44WE225

Elbow 22.50-Degree Feed-Through, 4.00x4.00, Gray, Steel

How to Install the Feed-Through Wireway

This guide provides step-by-step instructions for installing and configuring the Feed-Through Wireway, ensuring proper assembly and connection.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Gaskets, Terminal connectors, Cap nuts, Lockwashers

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.

  2. Install the telescope fitting

    Assemble the telescope fitting parts in the correct order, insert it into the straight section, and adjust to the desired length. Ensure the gasket is properly seated and secure with the compression ring using screws and nuts.

  3. Anchor the telescope fitting

    Drill .25 inch diameter holes through the straight section and telescope fitting at the desired extension. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.

  4. Cut the wireway to length

    Cut the wireway body to the desired length, ensuring a square cut. Weld an extra flange to the body and grind off any burrs or sharp edges.

  5. Install the swivel nipple

    Position the wireway section, flange gasket, swivel ring, and swivel nipple in order. Secure the assembly with clips, screws, and nuts.

  6. Make box entries

    Cut out the necessary openings in the enclosure for box entries as shown in the details. Position the box connector and gasket inside the enclosure, and secure the wireway section to the outside.

  7. Verify installation

    Use a multimeter to check for proper grounding continuity across the wireway and fittings. Ensure all connections are secure and that the installation meets safety standards.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.