nVent F44T172GV - Straight Section Layin Flat Cover Type 1 no KOs, 4x4x72, Galvanized, Steel
nVent

F44T172GV

UPC: 783510882204


Documents & Media
Installation InstructionsVideo Clip

Contact for Pricing

Overview

The nVent **F44T172GV Straight Section Lay-in Flat Cover Type 1** is a premium galvanized steel wireway component designed to streamline cable management in industrial, commercial, and institutional applications. Engineered for durability and ease of installation, this 72-inch straight section (4x4x72) provides a robust solution for enclosing and protecting electrical wiring while eliminating the need for labor-intensive cable pulling. Its open-side design allows wires and cables to be laid in directly along the wireway run, reducing the risk of insulation damage—a common issue in traditional pull-through wiring systems. The flat cover design enables flush mounting against walls or ceilings, ensuring a clean, professional installation that meets aesthetic and safety standards. This Type 1-rated section is ideal for environments where corrosion resistance and structural integrity are critical. The galvanized steel construction delivers superior protection against moisture, chemicals, and harsh outdoor conditions, making it suitable for use in manufacturing plants, data centers, healthcare facilities, and outdoor utility installations. The absence of knockouts (KOs) provides a smooth interior surface, reducing friction and wear on cables during installation or future modifications. Keyhole screw slots on the flat cover simplify access for inspections, upgrades, or reconfigurations without the need for specialized tools. Professionals in electrical contracting, industrial maintenance, and facility management rely on nVent’s wireway systems for their reliability and compliance with industry standards. The F44T172GV is part of a comprehensive wireway solution that includes elbows, tees, and fittings, ensuring seamless integration into any cable management infrastructure. With lengths ranging from 12 to 120 inches, this straight section offers flexibility to accommodate both compact and expansive wiring runs. Whether used in new construction or retrofit projects, the nVent wireway system minimizes downtime, enhances safety, and supports long-term performance. nVent, a global leader in electrical and thermal management solutions, is trusted by engineers and contractors for products that combine innovation with durability. The F44T172GV reflects the company’s commitment to quality, backed by rigorous testing and adherence to NEMA Type 1 standards for general-purpose indoor use. For projects demanding a balance of functionality, longevity, and ease of installation, the nVent F44T172GV Straight Section is an unmatched choice in wireway infrastructure.
  • Lay-in Flat-Cover Type 1 Straight Sections are used for enclosing wire and cable in wireway runs
  • Sections are completely open on one side so wires and cables can be laid in along wireway run
  • No pulling through of wires or cables prevents damage to insulation that often occurs in a pull-through wiring system
  • Flat cover design allows for mounting flush with walls or ceilings
  • Keyhole screw slots on flat covers provide easy access. Galvanized material provides superior corrosion protection for outdoor applications
  • Sections are available in lengths from 12 inch to 120 inch, with or without knockouts.

Specifications

Application
Power Distribution
Color
Unpainted
Depth
72 in
Depth
13 IN
Depth
1,829 mm
Finish
Galvanized
Height
44 IN
Height
4
Height
102
Knockouts
False
Knockouts
No
Material
Mild Steel;Steel
Material
Mild Steel
Material
Galvanized Steel
Modification Services
No
NEMA Rating
Type 1
NEMA Rating
1
NEMA Rating
1 Indoor, electrical protection
Protection Rating
NEMA Type 1
Size
4x4x72 inch
Thickness
1.52 mm
Thickness
16 ga
Thickness
51.40mm (2.024")
Type
Straight Section
Type
Commercial Lay-in Galvanized Flat-Cover Type 1 Wireway;Straight Section
Type Number
Type 1
Weight
24 lb
Width
23 IN
Width
4
Width
102
Wireway
Lay-In NEMA Type 1 Galvanized Wireway
Package Dimensions (L x W x H)
72 IN x 4.25 IN x 4 IN
Package Dimensions (L x W x H)
182.88 cm x 10.795 cm x 10.16 cm
Package Weight (Imperial)
24.000 L
Package Weight (Metric)
10.886 kg
Straight Section Layin Flat Cover Type 1 KOs, 4x4x72, Galvanized, Steel

F44T172GVWK

Straight Section Layin Flat Cover Type 1 KOs, 4x4x72, Galvanized, Steel
Type 3R Wiring Trough - 6x6x12 - Galv/Gray

C3RWT612

Type 3R Wiring Trough - 6x6x12 - Galv/Gray
Wire Safe Fitting - 4 inch X 4 Inch External Coupling.

EGCEN

Wire Safe Fitting - 4 inch X 4 Inch External Coupling.
The T-70 raceway Base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 8 ft and Electric Ivory.

T70BEI8

The T-70 raceway Base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 8 ft and Electric Ivory.

How to Install nVent HOFFMAN Type 1 Snap Connect Wireway

This guide provides step-by-step instructions for connecting and securing sections of the nVent HOFFMAN Type 1 Snap Connect Wireway using its snap feature and fasteners.

Estimated time: 15m

Tools needed:

Screwdriver, Torque wrench (recommended)

Supplies needed:

Hex head screws (10-32x.250), Hex nuts (10-32), Lock washers (#10)

  1. Connect Wireway Sections

    Align two sections of the Type 1 Snap Connect Wireway. Push them together firmly until they audibly 'Click' into place, ensuring a secure initial connection.

  2. Install First Securing Screw

    Insert a 10-32x.250 hex head screw through the designated hole on the connected wireway sections. Secure it from the other side with a 10-32 hex nut and a #10 lock washer.

  3. Tighten First Securing Screw

    Using a screwdriver or torque wrench, tighten the first screw to a torque of 4.5 0.5 N*M [40 4.0 LBF*IN]. Ensure the connection is firm but do not overtighten.

  4. Install Second Securing Screw

    Insert a second 10-32x.250 hex head screw through the remaining designated hole on the connected wireway sections. Secure it from the other side with a 10-32 hex nut and a #10 lock washer.

  5. Tighten Second Securing Screw

    Using a screwdriver or torque wrench, tighten the second screw to a torque of 4.5 0.5 N*M [40 4.0 LBF*IN]. Verify both screws are securely fastened to complete the connection.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.