Authorized nVent Distributor
nVent F44LC - Cross Fitting Lay-in Hinged-Cover, 4.00x4.00, Gray, Steel

nVent F44LC Cross Fitting Lay-in Hinged-Cover, 4.00x4.00, Gray, Steel

UPC: 783510184209


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent F44LC (SKU: F44LC) is a 4.00 x 4.00 inch steel cross fitting designed for efficient industrial cable management. Manufactured by nVent, this Type 12 NEMA rated fitting provides a secure, four-way cable routing solution. Its lay-in hinged-cover design simplifies installation and maintenance by allowing direct cable placement and easy access. Constructed from durable, gray powder-coated steel, it offers corrosion resistance suitable for indoor industrial environments like manufacturing plants and processing facilities. The Type 12 rating ensures protection against dust and dripping water. This fitting is ideal for complex electrical layouts where multiple cable pathways converge from a single point, ensuring organized and compliant electrical infrastructure. Key features include four-way cable routing, lay-in design for simplified installation, a hinged cover for convenient access, robust steel construction, and Type 12 NEMA protection. Professionals in electrical contracting and industrial automation will find the nVent F44LC a reliable component for maintaining system reliability and safety.
  • Lay-in Hinged-Cover Cross Fittings are used for routing cables in four directions in wireway runs
  • Used when there are four branches, all open along the same side
  • Lay-in design for simplified cable installation
  • Hinged cover for convenient access
  • Type 12 NEMA rating for indoor protection

Specifications

Application
Power Distribution
Color
Gray
Color
Grey
Color Code
ANSI 61
Finish
Galvanized;Painted
Finish
Galvanized
Height
44 IN
Height
4 in
Height
101.6 mm
Height
102
IP Rating
IP54
Material
Mild Steel;Steel
Material
Mild Steel
Modification Services
Yes
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Protection Rating
NEMA Type 12
Sealing Plate Quantity
3
Sealing Plate Type
Flat
Thickness
14 ga
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Type
Industrial Lay-in Wireway
Type
Commercial Lay-in Painted Galvanized Hinged-cover Type 3R Wireway;Cross Fitting
Type Number
Type 12
Weight
8.7 lb
Width
102
Width
4 IN
Width
23 IN
Wireway
Lay-In NEMA Type 12 Wireway
Package Dimensions (L x W x H)
10.2 IN x 8.5 IN x 10.7 IN
Package Dimensions (L x W x H)
25.908 cm x 21.59 cm x 27.178 cm
Package Weight (Imperial)
8.700 L
Package Weight (Metric)
3.946 kg
Elbow 90-Degree Outside Top Opening, 4.00x4.00, Gray, Steel

F44LE9AC

Elbow 90-Degree Outside Top Opening, 4.00x4.00, Gray, Steel
N12 Wireway, Straight Section - 2.5 x 2.5 x 120 - Steel/Gray

1487B120

N12 Wireway, Straight Section - 2.5 x 2.5 x 120 - Steel/Gray
Wire Safe Fitting - 4 inch X 4 Inch External Coupling.

EGCEN

Wire Safe Fitting - 4 inch X 4 Inch External Coupling.
The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.

LDPH10IG6-A

The LDPH10 power rated Surface Raceway is a two-piece latching raceway with cover suitable for applications up to 600 V. It features pre-punched mounting holes and factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.52 inches wide by 0.86 inches deep. It meets TIA/EIA Standards, is UL5A Listed, and is UL Compliant. It is International Gray.
Elbow 90-Degree LayIn Wireway Top Opening, 12.00x6.00, Gray, Mild Steel

F126LE9A

Elbow 90-Degree LayIn Wireway Top Opening, 12.00x6.00, Gray, Mild Steel
Tee Fitting Lay-in Hinged Cover Top Opening, 12.00x6.00, Gray, Steel

F126LTA

Tee Fitting Lay-in Hinged Cover Top Opening, 12.00x6.00, Gray, Steel
Elbow 90-Degree LayIn Wireway Inside Opening, 12.00x6.00, Gray, Mild Steel

F126LE9B

Elbow 90-Degree LayIn Wireway Inside Opening, 12.00x6.00, Gray, Mild Steel
Cross Fitting Lay-in Hinged-Cover, 12.00x6.00, Gray, Steel

F126LC

Cross Fitting Lay-in Hinged-Cover, 12.00x6.00, Gray, Steel

How to Install the Lay-In Wireway

This guide provides step-by-step instructions for installing and sealing a Lay-In Wireway for effective cable management.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wrench

Supplies needed:

Mounting screws, Gaskets, Nuts, Sealing plates

  1. Assemble the wireway sections

    Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the installation details.

  2. Seal the joints

    After installing the wires, seal each joint between the sections using either the LSGQR fitting method or the 90° sealing plate method as described in the installation details.

  3. Install box entries

    Make a cutout in the control enclosure for the wireway entry, position the box connector and gasket inside the enclosure, and install a 90° angle sealing plate to ensure a secure fit.

  4. Adjust telescope fitting

    Assemble the compression ring, gasket, and retainer on the telescope fitting, insert it into the straight section, and adjust to the desired length before securing with screws and nuts.

  5. Anchor telescope fitting

    If the telescope fitting is used vertically, drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting, then install screws and cap nuts to secure.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.