Contact for Pricing
Overview
- Cross Fittings are used when there are four branches
- It can be used as a 90-degree elbow or a 90-degree flush tee by adding Closure Plates
- Dimensions: 10.00 x 10.00 x 5.25 inches (254 x 254 x 133 mm).
- Features a seamless foam-in-place gasket and external stainless steel clamps.
- Includes mounting feet for secure and easy installation.
Specifications
Application | Power Distribution |
Color | Gray |
Color Code | ANSI 61 |
Finish | Painted;Powder Coat |
Finish | Powder Coated |
Height | 44 IN |
Height | 10 |
Height | 64 |
IP Rating | IP66 |
Material | Mild Steel |
Material | Fiberglass |
Material | Mild Steel;Steel |
Modification Services | Yes |
Mounting Type | Feet |
Nema Rating | Type 4X |
NEMA Rating | 1 Indoor, electrical protection |
Protection Rating | NEMA Type 1 |
Size | 10.00 x 10.00 x 5.25 in (254 x 254 x 133 mm) |
Thickness | 51.40mm (2.024") |
Thickness | 1.9 mm |
Thickness | 14 ga |
Type | Cross Fitting |
Type | Commercial Lay-in Hinged-Cover Type 1 Wireway;Cross Fitting |
Type Number | Type 1 |
Weight | 19.2 lb |
Width | 2.5 |
Width | 64 |
Width | 23 IN |
Wireway | Lay-In NEMA Type 1 Hinged-Cover Wireway |
Package Dimensions (L x W x H) | 18.5 IN x 18.3 IN x 11.1 IN |
Package Dimensions (L x W x H) | 46.99 cm x 46.482 cm x 28.194 cm |
Package Weight (Imperial) | 19.200 L |
Package Weight (Metric) | 8.709 kg |

RAF10IG-X
The right angle fitting is a one-piece Surface Raceway fitting designed to transition your raceway around a corner while maintaining a 1" bend radius. It is made to be used with the LD10 raceway, in applications up to 50 V. It is a snap-on installation and measures 2.5 in length. It is constructed with ABS plastic, meets TIA/EIA, and is International Gray.How to Install the F1010X Lay-In Wireway
This guide provides step-by-step instructions for installing and configuring the F1010X Lay-In Wireway, ensuring proper assembly and sealing for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Drill, Wrench
Supplies needed:
Mounting screws, Gaskets, Terminal connectors, 90° angle sealing plates
- Assemble the wireway sections
Place a gasket between the flanges of the wireway sections and secure them using screws and nuts as shown in the assembly details.
- Seal the joints
For joints between lay-in sections, position the LSGQR fitting, leaving out the top flange screw on the hinge side. Install the fitting with a shoulder bolt through the flange and ensure gaskets are visible from above.
- Install box entries
Make a cutout in the control enclosure for the wireway entry. Position the box connector and gasket inside the enclosure, then install a 90° angle sealing plate as described in the sealing methods.
- Adjust telescope fitting
Assemble the compression ring, gasket, and retainer on the telescope fitting. Insert the body into the straight section and adjust to the desired length, ensuring the gasket is properly seated.
- Anchor the telescope fitting
If the telescope fitting is used vertically, drill .25 inch diameter holes through the sides and bottom of the straight section and telescope fitting. Install .25−20x.5 screws from the outside and secure with cap nuts and lockwashers.
- Calibrate the wireway
After installation, verify that all sections are securely fastened and that the wireway is level. Use a multimeter to check for continuity if the wireway is to be used for grounding.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.