Contact for Pricing
Overview
- Pre-fabricated cables for LED enclosure lights
- Cables provide time saving, easy mounting of the EL LED Enclosure Lights
- Engineered by nVent for reliable power delivery to enclosure lighting systems in demanding industrial environments.
- 24 VDC operation is standard and safe for a wide range of industrial applications and equipment.
- 2-pole configuration ensures a straightforward and secure electrical connection for consistent illumination.
Specifications
Application | Power Distribution; Controls and Drives |
Color | Gray |
Connection | Power Cable, 2-Pole |
Connection Type | Power Cable |
Consist Of | Connect. cable Grey 24VDC |
Construction | Cable, Power for EL LED Enclosure Lights, 3.28 Ft., 24 VDC, 2-Pole, Gray |
Finish | Smooth |
Input Voltage DC | 24-24 V |
Length | 3.28 ft |
Length | 1 m |
Material | Copper |
Package Quantity | 1 |
Poles | 2-Pole |
Rated Current | 10 A |
Rated Voltage U0/U (Um) | 50 V |
Series | EL LED Enclosure Lights |
Size | Length 3.3 Feet |
Size | 1.0 Meters |
Type | IEC Enclosure Accessories |
Type | Lighting and Sockets |
Voltage Rating | 24 VDC |
Weight | 0.24 lb |
Weight | 0.1 kg |
Works With | IEC |
Package Dimensions (L x W x H) | 12.3 IN x 8.86 IN x 1.2 IN |
Package Dimensions (L x W x H) | 31.242 cm x 22.5044 cm x 3.048 cm |
Package Weight (Imperial) | 0.240 L |
Package Weight (Metric) | 0.109 kg |
How to Install the LED Cabinet Light
This guide provides step-by-step instructions for installing and wiring the LED Cabinet Light safely and effectively.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Turn off power supply
Ensure the mains power is switched off before beginning any installation work to prevent electrical shock.
- Mount the LED light
Securely mount the LED light to a stable, flat surface using the provided mounting screws, ensuring it is level and fixed.
- Connect the power supply
Connect the power supply to the LED light as per the wiring diagrams provided in the documentation, ensuring all connections are secure.
- Install door switch (if applicable)
Connect a door-operated switch to the LED light as shown in the diagrams, ensuring it only affects the light it is connected to.
- Check connections
Verify that all connections are secure and that there are no loose parts inside the housing before proceeding.
- Turn on power supply
Restore power to the circuit and test the LED light to ensure it operates correctly.
- Calibrate and adjust
If necessary, adjust the positioning of the light and ensure it is functioning as intended.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.