
Contact for Pricing
Overview
- Pre-fabricated cables for LED enclosure lights
- Cables provide time saving, easy mounting of the EL LED Enclosure Lights
- Pre-fabricated design reduces installation time and wiring errors
- Durable, oil-resistant PVC jacket for harsh industrial environments
- CE and EAC approvals ensure compliance
Specifications
Application | Controls and Drives; Power Distribution |
Color | Black |
Connection | Through Wiring, 3-Pole |
Connection Type | Trough-Wiring |
Consist Of | Through-Wiring Black |
Construction | Cable, Through-Wiring for EL LED Enclosure Lights, 1.97 Ft., 100-24 VAC, 3-Pole, Black |
Finish | Smooth |
Input Voltage AC | 100-240 V |
Length | 0.6 m |
Length | 1.97 ft |
Material | Copper |
Package Quantity | 1 |
Rated Current | 10 A |
Rated Voltage U0/U (Um) | 250 V |
Size | Length 1.97 Feet |
Type | IEC Enclosure Accessories |
Type | Lighting and Sockets |
Weight | 0.33 lb |
Weight | 0.1 kg |
Works With | IEC |
Package Dimensions (L x W x H) | 12.3 IN x 8.86 IN x 1.2 IN |
Package Dimensions (L x W x H) | 31.242 cm x 22.5044 cm x 3.048 cm |
Package Weight (Imperial) | 0.330 L |
Package Weight (Metric) | 0.150 kg |
How to Install the LED Cabinet Light
This guide provides step-by-step instructions for installing and wiring the LED Cabinet Light safely and effectively.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Turn off the power
Switch off the mains power supply to ensure safety before beginning the installation.
- Mount the LED light
Securely attach the LED light to a stable, level surface using the appropriate mounting screws as shown in the installation diagrams.
- Connect the power supply
Connect the power supply to the LED light as indicated in the provided electrical connection diagrams, ensuring all connections are secure.
- Install the door switch
Connect a door-operated switch to the LED light as shown in the diagrams; ensure it is properly wired to control the light.
- Check connections
Verify that all electrical connections are secure and that there are no loose parts inside the housing before powering on.
- Power on and test
Turn on the power supply and test the LED light to ensure it operates correctly and is securely mounted.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.