Overview
- Description: To divide the enclosure front into sections when used in conjunction with the horizontal divider CDH/CDHK when no door is required.
- Material: 1.75 mm steel plate.
- Finish: RAL 7035 structured powder coating.
- Protection: Complies with IP 54.
- Pack quantity: 1 panel with mounting accessories.
- Mounting requirements: Add CDH for MC frames and use CDHK for MK frames. Use DPC/DPCV for top and bottom panels.
Specifications
Application | Power Distribution |
Color | Light Gray |
Color | Gray |
Color Code | RAL 7035 |
Depth | 17 mm |
Depth | 0.67 in |
Enclosure Material | Mild Steel |
Finish | Powder Coated |
Height | 44 IN |
Height | 5.91 in |
Material | Mild Steel |
Mounting Type | Screw-secured |
Product Family | Free-Standing |
Protection Rating | IP44 |
Series | nVent DPP |
Size | 150x600 mm |
Thickness | 0.07 in |
Thickness | 51.40mm (2.024") |
Type | Doors |
Width | 600 mm |
Width | 23.62 in |
Works With | IEC |
Package Dimensions (L x W x H) | 24 IN x 6.28 IN x 24.25 IN |
Package Dimensions (L x W x H) | 60.96 cm x 15.9512 cm x 61.595 cm |
Package Weight (Imperial) | 5.100 L |
Package Weight (Metric) | 2.313 kg |

CBS18KC1234
Support fasteners designed to secure conduit and electrical boxes to most structures. Manufactured from steel and spring steel with a pre-galvanized steel construction and Black Claw spring steel fasteners riveted to the part. The product measures 18 in wide, 2-1/8 in high, and 2 in deep, and is designed to mount 4 in square boxes to 1/2 in and 3/4 in conduit.
AB763
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
H8064HLL
8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting FeetFrequently Asked Questions
What is the purpose of the DPP01506R5 partial panel?
This partial panel divides the enclosure front into sections when used with horizontal dividers CDH/CDHK, and no door is required.
What material is the DPP01506R5 partial panel made of?
The partial panel is constructed from 1.75 mm thick mild steel plate.
What is the finish and color of the partial panel?
It has a RAL 7035 structured powder coating in a light gray color.
What are the dimensions of the DPP01506R5 partial panel?
The panel measures 5.91 inches in height, 23.62 inches in width, and 0.67 inches in depth.
What is the thickness of the steel plate used for the panel?
The steel plate used for the panel has a thickness of 0.07 inches.
What is the IP protection rating of this partial panel?
The partial panel complies with IP 54 protection standards.
What accessories are needed for mounting the partial panel?
For mounting, use CDH for MC frames and CDHK for MK frames. DPC/DPCV are needed for top and bottom panels.
How is the partial panel secured for operator safety?
The panel is secured with screws, ensuring only service personnel can remove it for operator safety.
How to Mount the DPP01506R5 Power Distribution Unit
This guide outlines the physical mounting procedure for the DPP01506R5 unit, including screw specifications and torque settings for secure installation.
Estimated time: 30m
Tools needed:
Torque wrench, Screwdriver
Supplies needed:
M6x12 screws (Qty 2)
- Prepare Mounting Location
Identify the appropriate mounting location for the DPP01506R5 unit. Ensure the surface is clean, stable, and provides adequate space for installation and future access.
- Secure the Unit
Position the DPP01506R5 unit against the prepared mounting surface. Insert two M6x12 screws into the designated mounting points on the unit to hold it in place.
- Apply Final Torque
Using a torque wrench, tighten the M6x12 screws to a torque of 8-10 Nm. Ensure both screws are tightened evenly to prevent stress on the unit and ensure a secure mount.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.