nVent D723646SDAS Seismic Free-Stand DA Cabinet Type 3R 4 4X 12, 72x36x46, Brushed, SS304
UPC: 783510354510
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Reinforced stainless steel construction protects networking/communication equipment from corrosion, liquid, and seismic activity
- Six seismic bottom-mounting plates made of painted plated steel for 5/8-inch diameter anchors
- Lifting eyes installed for ease of handling
- Rack angles included are infinitely adjustable from front-to-rear supporting multiple networking/communication equipment configurations
- 36-inch wide models include integral, vertical, RU-aligned fingers for supporting copper and fiber networking cables
- AC models available for heat management
- Data pockets included for equipment information management/organization
- Seismic bottom-mounting plates (qty. 6) made of painted plated steel for 5/8-in. diameter anchors
- Internal mounting channels welded horizontally to sides at top, bottom and center
- 36-in. wide models include 2 Seismic Rack Panel Kits with EIA 310 specified square-holes (.375 x .375) that are infinitely adjustable front to rear
Specifications
Application | Networking, Storage and Data Center; Datacom and Telecom Equipment |
Application | Datacom and Telecom Equipment;Networking, Storage and Data Center |
Color | Unpainted |
Color | Brushed |
Depth | 1,173 mm |
Depth | 46.16 in |
Finish | Brushed #3 |
Height | 1,834 mm |
Height | 72.22 in |
Ip Rating | IP4X |
Material | Stainless Steel 304 |
Modification Services | Yes |
Mounting Type | Free-stand |
Nema Rating | Type 3R/4X |
Product Type | Standard |
Rack Units | 32 U |
Series | Seismic Free-Stand DA Cabinet |
Size | 72x36x46 |
Thickness | 2.78 mm |
Thickness | 12 ga |
Thickness | 51.40mm (2.024") |
Type | Data Networking Freestanding Cabinets |
Weight | 723 lb |
Width | 36.14 in |
Width | 918 mm |
Package Dimensions (L x W x H) | 62 IN x 43 IN x 81.75 IN |
Package Dimensions (L x W x H) | 157.48 cm x 109.22 cm x 207.645 cm |
Package Weight (Imperial) | 723.000 L |
Package Weight (Metric) | 327.953 kg |

T200246G406
The nVent T200246G406 industrial cable gland is a robust, UL-listed solution engineered for secure cable entry and sealing in demanding industrial environments. Designed for use in hazardous locations, this cable gland ensures reliable protection against moisture, dust, and mechanical stress while maintaining electrical integrity. Manufactured in the USA by nVent, a global leader in electrical and thermal management solutions, the T200246G406 meets stringent industry standards for durability and performance. This cable gland is ideal for applications requiring ingress protection (IP68/IP69K) and flame resistance, making it suitable for industries such as oil and gas, chemical processing, mining, and renewable energy. Its heavy-duty construction features corrosion-resistant materials, ensuring long-term reliability even in extreme temperatures and corrosive atmospheres. The T200246G406 is compatible with a wide range of cable diameters, providing flexibility for various installation requirements. Key features of the nVent T200246G406 include: - **High ingress protection (IP68/IP69K)**: Resists water, dust, and high-pressure cleaning, ensuring compliance with NEMA 4X and IEC 60529 standards. - **Flame-resistant materials**: Meets UL 94 V-0 and IEC 60695-11-10 for enhanced safety in hazardous environments. - **Corrosion-resistant construction**: Built with stainless steel and nickel-plated brass components to withstand harsh chemical exposure. - **Wide cable compatibility**: Accommodates a broad range of cable diameters, reducing the need for multiple gland sizes. - **Easy installation**: Features a threaded design for quick and secure attachment, minimizing downtime during installation or maintenance. Professionals in industrial electrical installations rely on nVent cable glands for their proven performance and compliance with global safety standards. The T200246G406 is particularly well-suited for: - **Hazardous location wiring**: Class I, II, and III, Division 1 & 2 environments where explosion-proof protection is critical. - **Outdoor and underground installations**: Provides reliable sealing against environmental ingress in exposed or buried applications. - **Heavy machinery and equipment**: Ensures cable integrity in vibration-prone or high-movement scenarios. - **Renewable energy systems**: Protects cables in solar, wind, and battery storage installations subject to weather extremes. nVent’s reputation for innovation and quality is underscored by its adherence to rigorous testing and certification processes. The T200246G406 cable gland is backed by nVent’s global technical support and a comprehensive warranty, offering peace of mind for engineers and installers. Whether you’re retrofitting existing systems or designing new infrastructure, this cable gland delivers the reliability and protection required for mission-critical operations.
T200248G150P
The nVent T200248G150P grounding connector, manufactured by nVent, is a critical component for establishing reliable electrical grounding systems. Engineered from high-quality copper alloy, this connector ensures exceptional conductivity and corrosion resistance, vital for long-term performance in demanding industrial environments. Its robust construction is designed to withstand harsh conditions, making it suitable for a wide array of applications across various sectors. This specific model is designed for secure attachment to a 1/2" diameter ground rod, providing a robust and dependable connection point for grounding conductors. The precision engineering of the nVent T200248G150P guarantees a low-resistance path to earth, which is paramount for protecting personnel and equipment from electrical surges, lightning strikes, and fault currents. Proper grounding is not merely a safety requirement; it is an essential element for the stable and efficient operation of sensitive electronic equipment and machinery. Key applications for the nVent T200248G150P include: * **Utility Substations:** Ensuring the safety and reliability of power distribution networks. * **Telecommunications Infrastructure:** Protecting sensitive communication equipment from electrical disturbances. * **Industrial Facilities:** Grounding heavy machinery, control panels, and electrical systems in manufacturing plants. * **Renewable Energy Installations:** Grounding solar arrays, wind turbines, and associated power conversion equipment. * **Commercial Buildings:** Providing essential safety grounding for electrical systems. The selection of a grounding connector is a crucial step in the design and installation of any electrical system. Professionals rely on components like the nVent T200248G150P for their proven performance and adherence to stringent industry standards. The copper alloy material offers superior durability compared to less resistant metals, minimizing the risk of degradation over time due to environmental factors such as moisture and chemical exposure. This longevity translates to reduced maintenance costs and enhanced system integrity. nVent is a globally recognized leader in electrical connection and protection solutions, known for its commitment to innovation, quality, and safety. Their products are trusted by engineers and installers worldwide for their reliability and performance. The T200248G150P grounding connector exemplifies this dedication, offering a secure, efficient, and long-lasting solution for critical grounding needs. Its origin in the United States further underscores a commitment to manufacturing excellence and adherence to rigorous quality control measures. When specifying grounding components, choosing a reputable manufacturer like nVent and a product designed for optimal performance, such as the T200248G150P, is a fundamental aspect of ensuring a safe and functional electrical infrastructure.
EW60MOPL8KOVR
The nVent EW60MOPL8KOVR is a high-performance electrical component designed for demanding industrial applications. Engineered for reliability and durability, this product ensures efficient power distribution and control in critical systems. Manufactured in the US, it meets stringent quality standards and is ideal for industrial automation, manufacturing, and infrastructure projects. Its robust construction and advanced features make it a trusted choice for professionals seeking dependable performance in harsh environments.
EW60MOPLUNDR8K
The nVent EW60MOPLUNDR8K is a high-quality industrial electrical enclosure designed to provide superior protection and organization for electrical components in demanding environments. Engineered for durability and reliability, this enclosure ensures optimal performance in industrial settings. Its robust construction and precise design make it ideal for applications requiring secure housing for sensitive electrical equipment. Trust nVent for superior electrical solutions that meet the highest industry standards.
EW24MOPLUNDR8K
The nVent EW24MOPLUNDR8K is a high-performance electrical enclosure designed for industrial applications requiring superior protection and organization. Engineered for durability, this enclosure ensures reliable performance in harsh environments, safeguarding critical electrical components from dust, moisture, and mechanical damage. Its modular design allows for easy installation and maintenance, making it ideal for industrial automation, power distribution, and control systems. With a focus on safety and efficiency, the nVent EW24MOPLUNDR8K meets stringent industry standards, providing peace of mind for demanding operational needs.How to Safely Handle and Install Large Hoffman Enclosures
This guide provides instructions for safely handling and installing large Hoffman enclosures, emphasizing precautions to prevent injury and equipment damage.
Estimated time: 1h
Tools needed:
Forklift, Overhead lifting device (e.g., crane), Slings with load-rated hooks or shackles, ROLL•A•LIFT™ or similar device (for some models)
Supplies needed:
3000 lb.-rated chain or strap (for securing to forklift mast), Rigging equipment (for overhead lifting)
- Read Safe Handling Requirements
Before moving or installing the enclosure, thoroughly read and understand the 'Large Enclosure Safe Handling Requirements' document that accompanied the enclosure. Ensure the route is clear of obstructions and all personnel are at a safe distance.
- Prepare for Movement
Ensure the enclosure is stabilized before removing any strapping. Verify that the lifting equipment (forklift or overhead device) has a sufficient load rating for the enclosure's weight and size. Only trained and authorized personnel should operate the lifting equipment.
- Position Forklift Forks
For forklift handling, spread the forks to the maximum distance or as dictated by the skid width. Enter the skid from the rear (Side A) of the enclosure. Position the enclosure carefully on the forks, keeping the load against the carriage/mast and tilting the load backward towards the mast.
- Secure Enclosure to Forklift
If using a forklift, secure the enclosure to the forklift mast before moving. Insert a 3000 lb.-rated chain or strap through the eye bolts provided on top of the enclosure and fasten it securely to the forklift mast assembly. Ensure sufficient tension to prevent tipping.
- Lift and Transport Enclosure
Lift the enclosure a minimum distance so the skid is just clear of the floor. Start and stop the forklift slowly and gradually, avoiding jerky movements. Drive slowly with the forks carried as low to the ground as possible. Never attempt to move more than one enclosure at a time.
- End Loading/Unloading (if applicable)
For end loading/unloading on trailers, spread forks to match pallet end slot openings and enter from the narrow side (C or D). Secure the enclosure to the forklift mast using chains or straps. Tilt the mast to take weight off the opposite end and slide/push the enclosure as required. Do not use chains or straps to lift the enclosure.
- Overhead Lifting (if applicable)
If using overhead lifting, attach rigging to the eye bolts, ensuring the angle between lifting cables and the vertical does not exceed 45 degrees. Use slings with adequate load-rated hooks or shackles. Ensure the load rating of the lifting device and rigging is sufficient. Do not use ropes or cables through eye bolts.
- Final Placement
Once the enclosure is at its final location, carefully position it. Ensure it is stable and permanently installed according to any specific product instructions not covered in this general handling guide. Refer to the nameplate or datasheet for model-specific details.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.