Contact for Pricing
Overview
- Drawn enclosure
- No welded seams or sharp corners
- Removable door with unique lift-off hinges
- Oil-tight quarter-turn slotted latches
- Oil-resistant gasket
- Weldnuts provided for mounting optional panels
- Bonding provision on door
Specifications
Application | Controls and Drives |
Color | Gray |
Color Code | ANSI 61 |
Conductive Panel | A10P8G |
Depth | 13 IN |
Depth | 4 in |
Depth, Maximum | 4 |
Depth, Minimum | 4 |
Finish | Powder Coated |
Height | 10 IN |
Height | 44 IN |
IP Rating | IP55 |
Material | Mild Steel;Steel |
Material | Steel |
Modification Services | Yes |
Nema Rating | Type 12 |
NEMA Rating | 12 |
Overall Dimensions | 114 x 88 mm |
Overall Dimensions | 10.09 x 8.45 in |
Panel | A10P8 |
Panel Size | 72.00 x 72.00 in |
Panel Size | 8.75 x 6.88 in |
Protection Rating | NEMA Type 12 |
Size | 10.00x8.00x4.00 |
Size | 10x8x4 inch |
Size | 10.00x8.00x4.00 in |
Thickness | 16 ga |
Thickness | 51.40mm (2.024") |
Type | Mild Steel Industrial Terminal and Junction Boxes |
Type | Mild Steel Terminal and Junction Boxes |
Type Number | Type 12 |
Weight | 6 lb |
Width | 203 mm |
Width | 8 in |
Package Dimensions (L x W x H) | 10 IN x 8 IN x 4 IN |
Package Dimensions (L x W x H) | 25.4 cm x 20.32 cm x 10.16 cm |
Package Weight (Imperial) | 6.000 L |
Package Weight (Metric) | 2.722 kg |
How to Install the Mounting Foot Kit for DMFK1 and DMFK2
This guide provides step-by-step instructions for installing the mounting foot kit on the DMFK1 and DMFK2 enclosures.
Estimated time: 30m
Tools needed:
Center punch, Drill, Screwdriver, Torque wrench
Supplies needed:
Mounting foot studs, Sealing washers, Nuts
- Locate mounting holes
Identify the locations for the mounting foot studs using the provided dimensions.
- Drill holes
Use a center punch to mark the centers of the holes, then drill four .219 inch diameter holes at the marked locations.
- Insert mounting foot studs
Insert the mounting foot studs into the drilled holes and turn the enclosure upright.
- Prepare sealing washers
Lightly lubricate the sealing washers and press them onto the mounting foot studs with the neoprene side facing down.
- Secure with nuts
Thread the nuts onto the studs and tighten them to a torque of 15 to 20 in-lbs.
- Complete installation
Repeat steps 3 to 5 for the other end of the enclosure to complete the installation.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.