nVent CTS66TICSS - 90-Degree Tee CleanTray Inside Cover Sloped, 6.00x6.00, Brushed, SS304
nVent

CTS66TICSS

UPC: 783510178178


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CTS66TICSS 90-Degree Tee Inside Cover Sloped is a premium stainless steel component engineered for CleanTray cable management systems, specifically designed to facilitate right-angle installations where two 90-degree transitions are required. Part of nVent’s industry-leading CleanTray stainless steel system, this tee inside cover provides robust protection for rated cabling in environments demanding frequent washdown, such as food and beverage processing, pharmaceutical manufacturing, and other hygienic industrial applications. Constructed from high-quality brushed 304 stainless steel, the CTS66TICSS ensures exceptional corrosion resistance, durability, and compliance with stringent hygiene standards, making it ideal for facilities where cleanliness and reliability are non-negotiable. Engineered for seamless integration, the sloped design of this inside cover promotes efficient drainage and minimizes water pooling, reducing the risk of moisture ingress and contamination. The 6.00x6.00 inch dimensions ensure compatibility with standard CleanTray systems, providing a secure fit for cable pathways while maintaining system integrity. As part of nVent’s CleanTray portfolio—renowned for its robust construction and compliance with NEMA 4X and IP66 ratings—this tee inside cover delivers uncompromising performance in harsh industrial environments. Whether used in wet processing areas, washdown zones, or high-humidity facilities, the CTS66TICSS ensures continuous protection for critical cabling infrastructure. Selecting the right cable management components is critical for maintaining operational efficiency and safety in industrial settings. The nVent CleanTray system, including the CTS66TICSS, is trusted by engineers and facility managers for its ability to withstand rigorous washdown procedures without compromising cable protection. The brushed stainless steel finish not only enhances corrosion resistance but also simplifies cleaning and maintenance, aligning with industry best practices for hygiene and compliance. Installation is straightforward, with the tee design allowing for quick assembly and alignment within the cable tray network, reducing downtime and labor costs. Industries that benefit most from the CTS66TICSS include food and beverage production, dairy processing, breweries, pharmaceuticals, and chemical manufacturing—sectors where regulatory compliance and operational reliability are paramount. The CleanTray system’s stainless steel construction ensures long-term performance, even in applications exposed to high-pressure washdowns, corrosive chemicals, or extreme temperatures. By choosing nVent, professionals gain access to a manufacturer with decades of expertise in electrical and mechanical solutions, ensuring that every component meets the highest standards of quality and innovation. For facilities prioritizing durability, hygiene, and compliance, the nVent CTS66TICSS 90-Degree Tee Inside Cover Sloped is an indispensable addition to any CleanTray cable management system. Its robust design, seamless integration, and manufacturer-backed reliability make it the preferred choice for protecting rated cabling in the most demanding industrial environments.
  • Clean Tray 90-Degree Tees are used for right-angle installations where two 90-degree transitions are required
  • The Clean Tray stainless steel system is designed to protect rated cabling in applications that require frequent washdown
  • Constructed from brushed 304 stainless steel for corrosion resistance
  • Compatible with CleanTray systems for rated cable protection
  • NEMA 4X and IP66 rated for harsh industrial environments

Specifications

Application
Hygienic Environments; Power Distribution; Corrosive Environments
Color
Unpainted
Color
Brushed
Finish
Brushed #3
Height
6 IN
Height
152 mm
IP Rating
IP66
Material
Stainless Steel
Material
SS304 Stainless Steel
Modification Services
No
NEMA Rating
1 Indoor, electrical protection
Nema Rating
NEMA 4X
Product Family
CleanTray
Protection Rating
NEMA Type 1
Series
CleanTray
Size
6.00x6.00
Thickness
1.27 mm
Thickness
18 ga
Type
Industrial Lay-in Wireway
Type
Tee
Weight
10.1 lb
Width
152 mm
Width
6 IN
Wireway
Clean Tray Stainless Steel Cable Tray
Package Dimensions (L x W x H)
20.5 IN x 13.75 IN x 7.25 IN
Package Dimensions (L x W x H)
52.07 cm x 34.925 cm x 18.415 cm
Package Weight (Imperial)
10.100 L
Package Weight (Metric)
4.581 kg
90-Degree Tee CleanTray Top Cover Sloped Outward, 4.00x6.00, Brushed, SS304

CTS46TFCOSS

90-Degree Tee CleanTray Top Cover Sloped Outward, 4.00x6.00, Brushed, SS304

How to Install the CT46EIC45SS Controller

This guide provides step-by-step instructions for installing and configuring the CT46EIC45SS controller, ensuring proper wiring and setup for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the CT46EIC45SS controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage matches the specifications outlined in the user manual.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure in the user manual to ensure the controller operates accurately. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.