nVent CT46TICSS - 90-Degree Tee CleanTray, 4.00x6.00, Brushed, SS304
nVent

CT46TICSS

UPC: 783510157821


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CT46TICSS 90-Degree Tee Inside Cover is a critical component within the nVent Clean Tray Stainless Steel Cable Management System. Engineered for demanding industrial environments, this tee fitting facilitates precise right-angle transitions where two 90-degree pathways are required. Its robust construction from SS304 stainless steel ensures exceptional corrosion resistance, making it ideal for applications subjected to frequent washdowns, corrosive atmospheres, or stringent hygiene standards. The Clean Tray system is specifically designed to protect rated cabling, maintaining its integrity and performance even under harsh conditions. The 'Inside Cover' design of this tee fitting offers a clean, streamlined aesthetic and can provide additional protection for the cable pathway. The 4.00x6.00 inch dimensions (AxB) are standard for many industrial cable management needs, offering flexibility in system design. Key features and benefits of the nVent CT46TICSS include: * **Durable SS304 Stainless Steel Construction:** Provides superior resistance to rust, corrosion, and chemical attack, ensuring longevity in demanding environments. * **90-Degree Tee Configuration:** Enables seamless creation of two 90-degree turns from a single junction point, simplifying complex routing. * **Inside Cover Design:** Offers a clean finish and enhanced cable protection. * **Designed for Washdown Applications:** The stainless steel material and robust design are perfect for food and beverage processing, pharmaceutical manufacturing, chemical plants, and other facilities requiring regular cleaning. * **nVent Quality and Reliability:** Backed by nVent's reputation for producing high-performance, dependable industrial solutions. This tee fitting is essential for maintaining organized and protected cable pathways in sectors such as petrochemical, wastewater treatment, and any industrial setting where cable integrity is paramount. The precise engineering of nVent's Clean Tray system minimizes cable stress and damage, contributing to overall system reliability and reduced maintenance downtime. When planning complex cable routes that involve multiple directional changes, the nVent CT46TICSS provides a robust and compliant solution.
  • Clean Tray 90-Degree Tees are used for right-angle installations where two 90-degree transitions are required
  • The Clean Tray stainless steel system is designed to protect rated cabling in applications that require frequent washdown
  • Material: SS304 Stainless Steel for superior corrosion resistance
  • Designed for applications requiring frequent washdowns and protection of rated cabling
  • Facilitates two 90-degree transitions from a single junction point

Specifications

Application
Power Distribution; Hygienic Environments; Corrosive Environments
Color
Unpainted
Finish
Brushed #3
Height
4 IN
Height
102 mm
Material
Stainless Steel
Material
SS304 Stainless Steel
Modification Services
Yes
NEMA Rating
1 Indoor, electrical protection
Product Family
CleanTray
Protection Rating
NEMA Type 1
Series
Clean Tray
Size
4.00x6.00 inches
Thickness
18 ga
Thickness
1.27 mm
Type
Tee
Type
Industrial Lay-in Wireway
Weight
7.3 lb
Width
6 IN
Width
152 mm
Wireway
Clean Tray Stainless Steel Cable Tray
Package Dimensions (L x W x H)
20.3 IN x 14.1 IN x 7.3 IN
Package Dimensions (L x W x H)
51.562 cm x 35.814 cm x 18.542 cm
Package Weight (Imperial)
7.300 L
Package Weight (Metric)
3.311 kg
90-Degree Tee CleanTray Outside Cover, 4.00x6.00, Brushed, SS304

CT46TOCSS

90-Degree Tee CleanTray Outside Cover, 4.00x6.00, Brushed, SS304
90-Degree Elbow CleanTray Top Cover Sloped Inward, 4.00x6.00, Brushed, SS304

CTS46EFC90SS

90-Degree Elbow CleanTray Top Cover Sloped Inward, 4.00x6.00, Brushed, SS304
90-Degree Elbow CT Top Cover Sloped Inward Perf, 4.00x6.00, Brushed, SS304

CTS46PEFC90SS

90-Degree Elbow CT Top Cover Sloped Inward Perf, 4.00x6.00, Brushed, SS304
90-Degree Elbow CleanTray Outside Cover Sloped, 4.00x6.00, Brushed, SS304

CTS46EOC90SS

90-Degree Elbow CleanTray Outside Cover Sloped, 4.00x6.00, Brushed, SS304
90-Degree Tee CleanTray Outside Cover Sloped, 4.00x6.00, Brushed, SS304

CTS46TOCSS

90-Degree Tee CleanTray Outside Cover Sloped, 4.00x6.00, Brushed, SS304
90-Degree Elbow CT Top Cover Sloped Inward no Tabs, 4.00x6.00, Brushed, SS304

CTS46EFCNT90SS

90-Degree Elbow CT Top Cover Sloped Inward no Tabs, 4.00x6.00, Brushed, SS304
90-Degree Elbow CleanTray Outside Cover, 4.00x6.00, Brushed, SS304

CT46EOC90SS

90-Degree Elbow CleanTray Outside Cover, 4.00x6.00, Brushed, SS304
90-Degree Elbow CleanTray Inside Cover, 4.00x6.00, Brushed, SS304

CT46EIC90SS

90-Degree Elbow CleanTray Inside Cover, 4.00x6.00, Brushed, SS304
45-Deg Elbow Top Cover Slope Inward CleanTray, 4.00x6.00, Brushed, SS304

CTS46EFC45SS

45-Deg Elbow Top Cover Slope Inward CleanTray, 4.00x6.00, Brushed, SS304
45-Deg Elbow Perf Top Cover Slope Inward CleanTray, 4.00x6.00, Brushed, SS304

CTS46PEFC45SS

45-Deg Elbow Perf Top Cover Slope Inward CleanTray, 4.00x6.00, Brushed, SS304
90-Degree Tee CleanTray Inside Cover Sloped, 4.00x6.00, Brushed, SS304

CTS46TICSS

90-Degree Tee CleanTray Inside Cover Sloped, 4.00x6.00, Brushed, SS304
90-Degree Elbow CleanTray Inside Cover Sloped, 4.00x6.00, Brushed, SS304

CTS46EIC90SS

90-Degree Elbow CleanTray Inside Cover Sloped, 4.00x6.00, Brushed, SS304

How to Install the CT46EIC45SS Controller

This guide provides step-by-step instructions for installing and configuring the CT46EIC45SS controller, ensuring proper wiring and setup for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the CT46EIC45SS controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage matches the specifications outlined in the user manual.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure in the user manual to ensure the controller operates accurately. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.