nVent CT46CSS - Cross CleanTray, 4.00x6.00, Brushed, SS304
nVent

CT46CSS

UPC: 783510157944


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CT46CSS is a 4"x6" stainless steel cable tray cross fitting, part of the nVent CleanTray system. Constructed from 18-gauge SS304 stainless steel with a smooth brushed finish, it is engineered for environments requiring frequent washdowns, such as food and beverage processing, pharmaceutical, and chemical manufacturing. This fitting facilitates four-way cable routing. It is UL Classified as an equipment grounding conductor (File No. E263414) and NEMA/EEMAC Type 1 compliant, ensuring hygiene and corrosion resistance critical for these industries.
  • Clean Tray Crosses are used for routing Clean Tray cables in four directions
  • The Clean Tray stainless steel system is designed to protect rated cabling in applications that require frequent washdown
  • Smooth brushed finish for hygiene and corrosion resistance
  • Ideal for food/beverage, pharmaceutical, and chemical industries
  • UL Classified as an equipment grounding conductor (File No. E263414)
  • NEMA/EEMAC Type 1 compliant

Specifications

Application
Hygienic Environments; Corrosive Environments; Power Distribution
Color
Brushed
Color
Unpainted
Finish
Brushed #3
Height
4 IN
Height
102 mm
Material
Stainless Steel 304
Material
SS304
Modification Services
Yes
NEMA Rating
1 Indoor, electrical protection
Product Family
CleanTray
Protection Rating
NEMA Type 1
Size
4.00x6.00
Thickness
18 ga
Thickness
1.27 mm
Type
Cross Fitting
Type
Industrial Lay-in Wireway
Weight
11 lb
Width
152 mm
Width
6 IN
Wireway
Clean Tray Stainless Steel Cable Tray
Package Dimensions (L x W x H)
20.75 IN x 20.75 IN x 2 IN
Package Dimensions (L x W x H)
52.705 cm x 52.705 cm x 5.08 cm
Package Weight (Imperial)
11.000 L
Package Weight (Metric)
4.990 kg
90-Degree Tee CleanTray Top Cover Sloped, 4.00x6.00, Brushed, SS304

CTS46TFCSS

90-Degree Tee CleanTray Top Cover Sloped, 4.00x6.00, Brushed, SS304

How to Install the CT46EIC45SS Controller

This guide provides step-by-step instructions for installing and configuring the CT46EIC45SS controller, ensuring proper wiring and setup for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the CT46EIC45SS controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the controller's power terminals. Ensure the connections are tight and insulated to prevent short circuits.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals of the controller. Ensure the voltage matches the specifications outlined in the user manual.

  4. Configure initial settings

    Power on the controller and access the configuration menu. Set the desired parameters according to your application requirements.

  5. Calibrate the controller

    Follow the calibration procedure in the user manual to ensure the controller operates accurately. Adjust settings as necessary based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.