nVent CSD423012LG - Concept Single-Door Enclosure, 42.00x30.00x12.00, Lt Gray, Steel
nVent

CSD423012LG

UPC: 783510294861


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent CONCEPT Single-Door Enclosure, model CSD423012LG, is engineered for robust industrial protection and streamlined integration into demanding environments. Crafted from durable steel and finished in a light gray (RAL 7035) hue, this enclosure provides a secure and aesthetically pleasing housing for critical electrical and electronic components. Its substantial 42.00" x 30.00" x 12.00" dimensions offer ample space for a wide array of equipment, making it a versatile solution for diverse industrial applications. Designed with the modern industrial landscape in mind, the CONCEPT enclosure series boasts a clean, streamlined styling that complements any facility. The flush quarter-turn latches ensure a secure closure, protecting sensitive equipment from dust, moisture, and unauthorized access, while remaining easy to operate for maintenance personnel. This combination of security and accessibility is paramount in sectors such as manufacturing, automation, power distribution, and telecommunications, where uptime and component integrity are critical. The CSD423012LG is built to withstand the rigors of industrial settings. The robust steel construction offers excellent mechanical strength and resistance to impact, safeguarding internal components from physical damage. The light gray, durable finish not only enhances the enclosure's lifespan by providing corrosion resistance but also contributes to a professional appearance within the plant floor or control room. This attention to detail in material selection and finishing underscores nVent's commitment to producing high-quality, long-lasting industrial solutions. Key features and benefits of the nVent CONCEPT Single-Door Enclosure include: * **Robust Construction:** Made from high-quality steel for superior durability and protection. * **Secure Access:** Features flush quarter-turn latches for reliable security and easy operation. * **Ample Space:** Generous dimensions (42"x30"x12") accommodate a variety of equipment. * **Industrial Aesthetics:** Streamlined styling and a light gray (RAL 7035) finish for a professional look. * **Environmental Protection:** Designed to shield internal components from dust, moisture, and other environmental contaminants. This enclosure is an ideal choice for housing control panels, power supplies, networking equipment, and other essential industrial hardware. Its straightforward design facilitates efficient installation and maintenance, reducing downtime and operational costs. Professionals in electrical contracting, system integration, and plant management rely on nVent products for their consistent performance and adherence to industry standards. The UNSPSC code 39121324 further categorizes this product within the electrical enclosure systems market, highlighting its specific utility. When selecting an enclosure, factors such as environmental conditions, equipment size, mounting requirements, and accessibility needs are crucial. The CSD423012LG addresses these considerations with its sturdy build, practical design, and versatile application potential. Trust nVent, a recognized leader in electrical protection and connection solutions, to provide the reliability and performance your critical infrastructure demands. The "US" country of origin signifies adherence to stringent manufacturing standards.
  • Seams continuously welded and ground smooth
  • Corner-formed doors
  • Simple easy-to-remove and install hinge pins with built-in captivation clip
  • High-torque threadless studs and fasteners on door
  • Minimum-width body flange provides maximum door opening (210 degrees)
  • Door opens 210 degrees
  • External formed body flange
  • Panel mounting studs fit optional Concept panels and other accessories
  • Mounting holes in back of body for optional external wall-mount brackets
  • Removable door with hidden hinges for clean, aesthetic appearance

Specifications

Application
Controls and Drives
Body Thickness
1.9 mm
Body Thickness
14 ga
Body Thickness
16 ga
Color
Light Gray
Color
Gray
Color
Grey
Color Code
RAL 7035
Concept Panel
CP4230
Conductive Concept Panel
CP4230G
Depth
12
Depth
305 mm
Door Thickness
1.9 mm
Door Thickness
14 ga
Finish
Powder Coated
Height
1,067 mm
Height
42 mm
IP Rating
IP66
Latch Quantity
1
Latch Style
3-point
Latch Type
3-Point
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting
Wall Mounting Brackets Available
Mounting
40.50 x 28.50 in
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Panel Size
40.20 x 28.20 in
Panel Size
1021 x 716 mm
Product Family
Concept
Protection Rating
NEMA Type 12
Size
42.00x30.00x12.00 in
Type
Mild Steel Wall Mounted Industrial Enclosures
Type Number
Type 4
Weight
104 lb
Width
762 mm
Width
30 IN
Package Dimensions (L x W x H)
47 IN x 31.25 IN x 14 IN
Package Dimensions (L x W x H)
119.38 cm x 79.375 cm x 35.56 cm
Package Weight (Imperial)
104.000 L
Package Weight (Metric)
47.174 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the CSD302410SS6 Controller

This guide provides step-by-step instructions for installing and configuring the CSD302410SS6 Controller, ensuring proper wiring and setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors

  1. Mount the controller

    Secure the CSD302410SS6 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the wires and connect them to the appropriate terminals on the controller. Ensure all connections are tight and secure to prevent any electrical issues.

  3. Power on and configure

    Turn on the power supply to the controller. Use a multimeter to verify that the voltage levels are correct. Follow the manufacturer's instructions to configure the controller settings as needed.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.