nVent CR430816GW010 Water-Cooled Indoor/Outdoor AC CR43WC, 8500BTU 115V, Lt Gray, Steel
UPC: 783510209445
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Heat is removed from the system by means of the water cooling the refrigerant; no external air movers or condenser coils to get clogged
- Attractive industrial design with minimal use of visible fasteners
- R513A or R134a refrigerant
- Models for 115 and 230 VAC power input
- Operating temperature range from 50 F/10 C to 125 F/52 C
- Maximum water usage of 2 GPM at 90 F water intake temperature
- Reliable mechanical thermostat located behind the front panel of the unit
- Low-carbon mild-steel sheet-metal cover for rugged factory and outdoor environments
- Easy-mount flanges for simple installation
- Every unit functionally tested before shipping
Specifications
Application | Hazardous Environments; Power Distribution; Controls and Drives; Arc Flash Safety; Hygienic Environments; Corrosive Environments |
Application | Arc Flash Safety;Controls and Drives;Corrosive Environments;Hazardous Environments;Hygienic Environments;Power Distribution |
Color | Lt Gray |
Color | Light Gray |
Color | Gray |
Color Code | RAL 7035 |
Depth | 10.25 in |
Depth | 260 mm |
Finish | Powder Coated |
Height | 1,100 mm |
Height | 43.31 in |
Material | Steel |
Material | Mild Steel |
Max Current | 13 A |
Mechanical Advantage | Stainless steel optional |
Mounting Type | Indoor/Outdoor |
Mounting Type | Easy-mount flanges |
NEMA Rating | 12 Indoor, dust-resistant |
Nominal Capacity Btu/h | 8,500 Btu/h |
Nominal Capacity Watts | 2,490 W |
Nominal Voltage | 115 V |
Number Of Phases | 1 |
Operating Temperature | 10-55 °C |
Operating Temperature | 50-131 °F |
Outdoor Installation | No |
Product Family | ProAir |
Protection Rating | NEMA Type 12 |
Refrigerant | R134a |
Remote Access Control | No |
Series | CR43WC |
Size | 8500BTU |
Thickness | 51.40mm (2.024") |
Thickness | 1.52 mm |
Thickness | 16 ga |
Type | Air Conditioners |
Type | Heat Exchangers |
Voltage AC | 100-120 V |
Voltage Rating | 115 V |
Weight | 39 kg |
Weight | 137 lb |
Width | 400 mm |
Width | 15.75 in |
Package Dimensions (L x W x H) | 18 IN x 14 IN x 45 IN |
Package Dimensions (L x W x H) | 45.72 cm x 35.56 cm x 114.3 cm |
Package Weight (Imperial) | 137.000 L |
Package Weight (Metric) | 62.143 kg |
How to Install the CR430816GW010 Water-Cooled Air Conditioner
Installation guide for mounting and wiring the CR430816GW010 water-cooled air conditioner.
Estimated time: 45m
Tools needed:
Screwdriver, Wrench, Ratchet driver
Supplies needed:
Gasket kit, Mounting bolts, Mounting screws, Sealant
- Inspect and test the air conditioner
Inspect the air conditioner for any shipping damage. Before mounting, test the unit for functionality by connecting it to a properly grounded power supply and a clean, pressurized water supply. Ensure no excessive noise or vibration is present during the 5-10 minute test run. Refer to the nameplate for specific electrical requirements. Do not operate the unit if it has been in a horizontal position; allow it to remain upright for at least 5 minutes before operating.
- Prepare the enclosure
Using the provided cutout dimensions or template, prepare the air 'IN' and 'OUT' openings, and the mounting bolt hole pattern on the enclosure.
- Install gaskets
Using the provided gasket kit, install the gaskets to the air conditioner in the proper locations as indicated in the manual.
- Mount the air conditioner
Mount the air conditioner onto the enclosure using the provided mounting bolts and screws. EZ-mount tabs can assist in holding the unit in place. Connect the water inlet and outlet fittings to a clean, pressurized water supply using sealant. Ensure the unit remains upright for at least 5 minutes before starting operation.
- Connect electrical power
Refer to the top of the nameplate for electrical requirements. Connect the power cord to a properly grounded power supply. It is recommended that the electrical circuit be fused with a slow blow or HACR circuit breaker. Avoid using an extension cord.
- Verify water supply and drain
Connect the unit to a clean, pressurized water supply and ensure a drain is provided. Verify that water flows correctly and that the unit shuts down if the water supply is interrupted.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.