nVent CJDN2006R5 Depth Baying Kit, CJDN, 34x1964x28mm, Zinc Plated, Mild Steel, Depth 600mm
UPC: 783510459116
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Description: For baying enclosures rear to rear.
- Material: Covers: 2 mm mild steel. Brackets: 3 mm zinc plated steel.
- Finish: RAL 7035.
- Protection: IP 55
- Pack quantity: 1 kit with mounting accessories.
- RAL 7035 powder-coated finish for durability and aesthetics
- Direct earthing connection for enhanced safety
- Supplied with all necessary mounting accessories
Specifications
Application | Controls and Drives;Factory Automation and Process Control |
Application | Controls and Drives; Factory Automation and Process Control |
Color | RAL 7035 (Light Gray) |
Color | Light Gray |
Color | RAL 7035 |
Color | Gray |
Color | Grey |
Color | RAL 7035 Light Gray |
Color Code | RAL 7035 |
Consist of | Depth Baying Kit;Mounting Components and Instruction Manual |
Consist Of | Depth Baying Kit; Mounting Components and Instruction Manual |
Construction | 14 gauge |
Depth | 1.1 IN |
Depth | 28 mm |
Enclosure Material | Mild Steel |
Finish | Powder Coating |
Finish | Powder Coated |
Height | 1.34 in |
Height | 34 mm |
Material | Mild Steel, Zinc Plated |
Material | Mild Steel (2mm covers), Zinc-Plated Steel (3mm brackets) |
Material | Mild Steel |
Mounting Type | Rear-to-rear baying |
Mounting Type | Rear-to-Rear Baying, Floor-Standing |
Package Quantity | 1 |
Product Family | Free-Standing |
Series | CJDN |
Size | 34x1964x28mm, Depth 600mm |
Size | 1.34 x 77.32 x 1.1 inch |
Size | 34x1964x28mm |
Thickness | 14 ga |
Thickness | 51.40mm (2.024") |
Thickness | 2 mm |
Type | Baying |
Type | IEC Enclosure Accessories |
Weight | 35.3 lb |
Weight | 16 kg |
Weight | 32 lbs./100ft |
Width | 77.32 in |
Width | 1,964 mm |
Works With | IEC |
Package Dimensions (L x W x H) | 79.12 IN x 24 IN x 24.25 IN |
Package Dimensions (L x W x H) | 200.9648 cm x 60.96 cm x 61.595 cm |
Package Weight (Imperial) | 35.300 L |
Package Weight (Metric) | 16.012 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackFrequently Asked Questions
What are the safety instructions for installing nVent products?
nVent products must be installed and used only as indicated in nVent's product instruction sheets and training materials.
What is the purpose of the CJDN2006R5 baying kit?
The CJDN2006R5 baying kit increases the depth of an enclosure configuration to host larger equipment.
What materials are used for the CJDN2006R5 baying kit?
The covers are made of 2 mm mild steel, and the brackets are made of 3 mm zinc plated steel.
What is the finish and color of the CJDN2006R5 baying kit?
The baying kit has a RAL 7035 finish and is Light Gray in color.
What are the dimensions of the CJDN2006R5 baying kit?
The baying kit has a height of 1.34 inches, a width of 77.32 inches, and a depth of 1.1 inches.
What is the product family for the CJDN2006R5 baying kit?
The product family for the CJDN2006R5 baying kit is Free-Standing.
What is the IP protection rating for this baying kit?
The baying kit has an IP 55 protection rating.
What is the weight of the CJDN2006R5 baying kit?
The baying kit weighs 35.3lb.
What is the thickness of the CJDN2006R5 baying kit?
The thickness of the baying kit is 14ga.
How is the CJDN2006R5 baying kit packaged?
The baying kit is packaged as 1 kit with mounting accessories.
How to Install the CJDN2006R5 Controller
This guide provides step-by-step instructions for installing and configuring the CJDN2006R5 Controller on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the CJDN2006R5 controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect the power supply
Using terminal connectors, connect the power supply wires to the designated input terminals on the controller. Verify that the connections are secure.
- Configure the controller settings
Power on the controller and use the configuration interface to set the desired operational parameters. Refer to the user manual for specific settings.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure accurate performance. Use a multimeter to verify output signals during calibration.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.