nVent CEPRL5016 - Cable Entry Gld Plt Round, CEPR, 58x58x12mm 16 Entry, GY, Plastic
nVent

CEPRL5016

UPC: 783510582890


Documents & Media
Installation Instructions

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Overview

The nVent CEPRL5016 is a high-performance round cable entry plate designed for efficient and space-saving cable management in demanding industrial environments. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this CEPR series plate (SKU: CEPRL5016) offers a robust and reliable method for introducing multiple cables into enclosures, control panels, and machinery. Its compact dimensions of 58x58x12mm make it an ideal choice for applications where installation space is at a premium, yet a significant number of cable entries are required. The primary advantage of the nVent CEPRL5016 lies in its tool-free installation. This innovative design significantly reduces assembly time and labor costs, allowing for quicker project completion and maintenance. The round configuration, combined with 16 pre-defined openings, provides a versatile solution for routing a variety of cable diameters. The durable gray plastic construction ensures resistance to common industrial chemicals and environmental factors, contributing to the longevity and integrity of your electrical systems. This cable entry plate is particularly well-suited for industries such as automation, machine building, renewable energy, and telecommunications, where organized and protected cable ingress is critical. It helps maintain the NEMA or IP rating of enclosures by providing a sealed entry point, preventing dust, moisture, and other contaminants from entering sensitive electrical components. The structured layout of the 16 openings facilitates neat cable management, reducing the risk of tangles and simplifying future troubleshooting or modifications. Key benefits of the nVent CEPRL5016 include: * **Rapid Installation:** Tool-free assembly drastically cuts down on installation time. * **Space Efficiency:** Compact 58x58x12mm footprint is perfect for confined spaces. * **High Density Cable Entry:** Accommodates up to 16 individual cable entries. * **Durable Construction:** Made from robust gray plastic for long-term industrial use. * **Enclosure Protection:** Helps maintain NEMA/IP ratings by providing a sealed entry. * **Organized Cabling:** Facilitates neat and manageable cable routing. Professionals choose nVent for their commitment to quality, innovation, and reliability in electrical infrastructure solutions. The CEPRL5016 exemplifies this dedication by offering a practical, efficient, and cost-effective solution for complex cable management challenges. Whether you are designing new equipment or upgrading existing systems, the nVent CEPRL5016 provides the performance and ease of use necessary to ensure a secure and organized electrical installation. Its UNSPSC code is 39121321, and it is proudly manufactured in the USA.
  • Finish: Gray
  • Pack quantity: 10
  • Description: Quick and easy to install without tools, round cable entries are ideally suited for applications that require many incoming or outgoing cables or pneumatic conduits inside an enclosure. The snap-in system is designed for wall thicknesses of 1
  • Temperature resistance: -40°C to +90°C
  • Flammability: UL94 V-0
  • Protection: IP54, NEMA 1, 12 (indoor use only)
  • Material: TPE

Specifications

Application
Corrosive Environments; Controls and Drives
Cable Entry
(4) 1.0 - 5.3 mm
Cable Entry Quantity
16
Color
Gray
Configuration
4 x 1.0-5.3mm (.04-.21)
Cutout Size
1.97 Ø in
Cutout Size
50 Ø mm
Cutout Size
1.97 Ø in
Depth
12 mm
Depth
0.47 in
Finish
Untreated
Height
2.28 in
Height
58 mm
Material
Plastic
Operating Temperature
-40-194 °F
Operating Temperature
-40-90 °C
Product Family
Cable Manager
Protection Rating
NEMA Type 1
Type
Cable Entry Systems
Weight
0.047 lb
Weight
0.05 lb
Weight
0.02131519 kg
Width
58 mm
Width
2.28 in
Works With
NEMA
Package Dimensions (L x W x H)
8 IN x 6 IN x 1 IN
Package Dimensions (L x W x H)
20.32 cm x 15.24 cm x 2.54 cm
Package Weight (Imperial)
0.470 L
Package Weight (Metric)
0.213 kg
Cable Entry Gld Plt Round, CEPR, 58x58x12mm 20 Entry, GY, Plastic

CEPRL5020

Cable Entry Gld Plt Round, CEPR, 58x58x12mm 20 Entry, GY, Plastic
Feed through Terminal Blocks

DS2.5-TW-01P-11-00Z(H)

Feed through Terminal Blocks
Grey plastic hinges (2 pcs)

TH A

Grey plastic hinges (2 pcs)
A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.

RCR75J

A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.
Breather Kit

SDA412

Breather Kit
MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES

50265410

MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES
NEXT ENC 96HX45WX11D N1 PAINTED

ER9645A

NEXT ENC 96HX45WX11D N1 PAINTED
Plug, Knockout, Plastic, Size 3/4 Inch

9892

Plug, Knockout, Plastic, Size 3/4 Inch
3/4 Inch, Non-Metallic Insulated Bushing, For Use with Rigid/IMC Conduit, Bag of 5

BU502-5

3/4 Inch, Non-Metallic Insulated Bushing, For Use with Rigid/IMC Conduit, Bag of 5
8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

H8084HLL

8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

How to Install the CEPRL5016 Cable Entry Gland Plate

This guide provides step-by-step instructions for installing the CEPRL5016 Cable Entry Gland Plate, ensuring proper cable management and secure installation.

Estimated time: 15m

Tools needed:

Screwdriver

Supplies needed:

Cable entry gland plate, Cables

  1. Prepare the cutout

    Ensure the cutout for the cable entry gland plate is clean and free of debris. Verify that the dimensions match the specifications for the CEPRL5016.

  2. Install the cable entry

    Place the cable entry gland plate into the cutout. Pierce the membrane at the designated push-through point.

  3. Secure the installation

    Push the cables through from the outside and press the gland plate until all four sides snap securely into the cutout.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.