Authorized nVent Distributor
nVent CEPL1924 - Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 19 Entry, GY, Plastic

nVent CEPL1924 Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 19 Entry, GY, Plastic

UPC: 783510582999


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent CEPL1924 Rectangular Cable Entry Plate is a tool-free solution for managing up to 19 cables in industrial enclosures. Constructed from durable, halogen-free polyamide with a TPU/NBR/EPDM seal, it provides IP65 protection against dust and moisture ingress. The plate is V-0 rated per UL94 for flammability resistance, ensuring safety in high-temperature environments. Measuring 44x142x12mm, it fits compact spaces while accommodating panel thicknesses from 1.4mm to 2mm via snap-in fastening or screw mounting. With an operating temperature range of -30°C to +70°C, it suits automation, telecommunications, renewable energy, manufacturing, and transportation infrastructure. Designed for unterminated cables and pneumatic conduits, the CEPL1924 simplifies cable entry without compromising enclosure integrity.
  • Finish: Gray
  • Pack quantity: 10
  • Description: Fast, cost-effective and tool-free cable entry for incoming cables and/or pneumatic conduits inside an enclosure. The snap-in system works for wall thicknesses of 1.5 to 2.5 mm.
  • Temperature resistance: -40°C to +90°C
  • Flammability: UL94 V-0
  • Protection: IP54, NEMA 1, 12
  • Material: TPE

Specifications

Application
Controls and Drives;Corrosive Environments
Application
Controls and Drives; Corrosive Environments
Cable Entry
(12) 0.04 - 0.26 ";(12) x 1.0 - 6.5 mm
Cable Entry
(12) 0.04 - 0.26 "
Cable Entry Quantity
19
Color
Gray
Color
Grey
Configuration
12 x 1.0-6.5mm (.04-.26)
Connection Type
Snap-in/Screw Mounting
Cutout Size
1.42 x 4.41 in
Cutout Size
36x112 mm
Cutout Size
18.69 x 7.19 in
Depth
0.47 in
Depth
12 mm
Finish
Untreated
Height
44 mm
Height
44 IN
Height
1.73 in
Material
Plastic
Material
Polyamide with TPU/NBR/EPDM seal
Material
Polyamide (Halogen-Free) with TPU/NBR/EPDM Seal
Mounting Type
Snap-in or Screw Mounting
Mounting Type
Snap-in fastening or screw mounting
Operating Temperature
-40-90 °C
Operating Temperature
-40-194 °F
Product Family
Cable Manager
Protection Rating
NEMA Type 1
Series
CEPL
Size
44x142x12 mm
Type
Cable Entry Systems
Weight
32 lbs./100ft
Weight
0.113 lb
Weight
0.1 kg
Width
142 mm
Width
5.59 in
Works With
NEMA
Package Dimensions (L x W x H)
10 IN x 5 IN x 3 IN
Package Dimensions (L x W x H)
25.4 cm x 12.7 cm x 7.62 cm
Package Weight (Imperial)
1.130 L
Package Weight (Metric)
0.513 kg
Cable Entry Gld Plt Round, CEPR, 58x58x12mm 12 Entry, GY, Plastic

CEPRL5012

Cable Entry Gld Plt Round, CEPR, 58x58x12mm 12 Entry, GY, Plastic
Inspection Window 14.84 x 13.03"

L 44 II

Inspection Window 14.84 x 13.03"
IME PLINTH 600X600

IPL66

IME PLINTH 600X600
Holder, Wire, Head Length 3.15 Inches, Hole Diameter 0.87 x 0.92 Inches, Screw Length 2-1/4 Inch, Porcelain

SW4BB

Holder, Wire, Head Length 3.15 Inches, Hole Diameter 0.87 x 0.92 Inches, Screw Length 2-1/4 Inch, Porcelain
STEEL INTERNAL SQUARE 90 DEGREE TO FIX PROFIL ON BLOCAL FRAMEWITH SCREW 8X12

SA104223

STEEL INTERNAL SQUARE 90 DEGREE TO FIX PROFIL ON BLOCAL FRAMEWITH SCREW 8X12
Support fasteners designed to secure conduit and electrical boxes to most structures. It is manufactured from steel and spring steel with a pre-galvanized steel construction and Black Claw™ spring steel fasteners riveted to the part. It is designed to mount 4" square boxes to 1" EMT or 3/4" rigid conduit.

CBS18HIC100

Support fasteners designed to secure conduit and electrical boxes to most structures. It is manufactured from steel and spring steel with a pre-galvanized steel construction and Black Claw™ spring steel fasteners riveted to the part. It is designed to mount 4" square boxes to 1" EMT or 3/4" rigid conduit.
PowerMark Gold Bond Screw Kit for 100-200 A.

TBS

PowerMark Gold Bond Screw Kit for 100-200 A.
8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

H8064HLL

8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet
Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack

SBL300

Box Support, Steel, Electro Galvanized 2 in. size, 2-1/2 in. length 100 per pack

Frequently Asked Questions

What is the operating temperature range for CEPL1924?

The CEPL1924 has a temperature resistance of -40°C to +90°C, or -40 to 194°F.

What NEMA and IP ratings does the CEPL1924 have?

The CEPL1924 is rated IP54 and meets NEMA Type 1 and 12 standards.

What is the flammability rating of the CEPL1924?

The CEPL1924 has a UL94 V-0 flammability rating.

How many cable entries does the CEPL1924 provide?

The CEPL1924 provides 19 cable entries.

What are the dimensions of the CEPL1924 cutout size?

The cutout size for the CEPL1924 is 1.42 x 4.41 inches.

What is the CEPL1924 made of?

The CEPL1924 is made of TPE plastic.

What is the pack quantity for the CEPL1924?

The CEPL1924 comes in a pack quantity of 10.

What are the dimensions of the CEPL1924?

The CEPL1924 measures 44x142x12mm, with a height of 1.73in, width of 5.59in, and depth of 0.47in.

What cable entry sizes does the CEPL1924 support?

The CEPL1924 supports 12 entries from 0.04 to 0.26 inches and 7 entries from 0.04 to 0.48 inches.

Can the CEPL1924 be installed without tools?

Yes, CEPL entries can be installed quickly and easily without using tools.

How to Install the CEPL1924 Cable Entry Gland Plate

This guide provides step-by-step instructions for installing the CEPL1924 Cable Entry Gland Plate into a cutout for effective cable management.

Estimated time: 15m

Tools needed:

Screwdriver

Supplies needed:

Cable entry gland plate

  1. Prepare the cutout

    Ensure the cutout is clean and free of debris to allow for proper installation of the cable entry gland plate.

  2. Insert the cable entry gland plate

    Place the cable entry gland plate into the cutout, aligning it properly for a secure fit.

  3. Secure the gland plate

    Pierce the membrane at the push-through point and push cables through from the outside. Press the plate in until all four sides snap securely into the cutout.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.