nVent CEPL1424 - Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 14 Entry, GY, Plastic
nVent

CEPL1424

UPC: 783510582968


Documents & Media
Installation Instructions

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Overview

The nVent CEPL Rectangular Cable Entry Gland Plate (SKU: CEPL1424) offers an efficient and tool-free solution for managing multiple cable or pneumatic conduit entries into enclosures, particularly in space-constrained environments. Designed by nVent, a leader in electrical enclosure solutions, this gland plate ensures a clean and protected cable ingress point, maintaining the integrity of your enclosure's environment. This robust plastic cable entry system is engineered for rapid installation, eliminating the need for specialized tools. Its integrated seal provides excellent protection against dust and moisture, helping to achieve an IP65 protection rating, crucial for demanding industrial applications. The CEPL series is ideal for situations where numerous cables need to enter or exit an enclosure, but internal or external space is at a premium. The snap-in fastening mechanism is designed for wall thicknesses ranging from 1.4 to 2 mm, offering a secure and reliable fit. For added versatility, it also supports screwing for installation. Key features and benefits of the nVent CEPL Rectangular Cable Entry Gland Plate include: * **Tool-Free Installation:** Significantly reduces installation time and labor costs. * **High Cable Density:** Accommodates up to 14 cable entries within a compact footprint. * **IP65 Protection:** Ensures effective sealing against dust and water ingress, safeguarding sensitive equipment. * **Durable Construction:** Made from high-quality Polyamide with a TPU/NBR/EPDM halogen-free seal, offering excellent temperature resistance (-30ºC to +70ºC) and V-0 flammability rating according to UL94. * **Versatile Mounting:** Supports both snap-in (1.4-2 mm wall thickness) and screw fastening for flexible installation. * **Compact Design:** Rectangular form factor (44x142x12mm) optimizes space utilization. Applications for the CEPL1424 are widespread across various industries, including manufacturing automation, control panels, telecommunications, and renewable energy systems. Wherever reliable and organized cable management is paramount, this nVent gland plate provides a dependable solution. The manufacturer's commitment to quality and innovation ensures that this product meets the rigorous demands of industrial environments. Trust nVent for your critical cable entry needs, ensuring operational efficiency and equipment longevity.
  • Finish: Gray
  • Pack quantity: 10
  • Description: Fast, cost-effective and tool-free cable entry for incoming cables and/or pneumatic conduits inside an enclosure. The snap-in system works for wall thicknesses of 1.5 to 2.5 mm.
  • Temperature resistance: -40°C to +90°C
  • Flammability: UL94 V-0
  • Protection: IP54, NEMA 1, 12
  • Material: TPE

Specifications

Application
Controls and Drives; Corrosive Environments
Cable Entry
(14) 1.0 - 12.1 mm
Cable Entry Quantity
14
Color
Gray
Configuration
12 x 1.0-15.0mm (.04-.59)
Cutout Size
1.42 x 4.41 in
Cutout Size
36x112 mm
Depth
0.47 in
Depth
12 mm
Finish
Untreated
Height
44 mm
Height
1.73 in
Material
Plastic
Operating Temperature
-40-90 °C
Operating Temperature
-40-194 °F
Product Family
Cable Manager
Protection Rating
NEMA Type 1
Type
Cable Entry Systems
Weight
0.0462585 kg
Weight
0.102 lb
Weight
0.1 lb
Width
5.59 in
Width
142 mm
Works With
NEMA
Package Dimensions (L x W x H)
9 IN x 6 IN x 2 IN
Package Dimensions (L x W x H)
22.86 cm x 15.24 cm x 5.08 cm
Package Weight (Imperial)
1.020 L
Package Weight (Metric)
0.463 kg
Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 17 Entry, GY, Plastic

CEPL1724

Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 17 Entry, GY, Plastic
Feed through Terminal Blocks

DS2.5-TW-01P-11-00Z(H)

Feed through Terminal Blocks
Grey plastic hinges (2 pcs)

TH A

Grey plastic hinges (2 pcs)
A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.

RCR75J

A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.
Breather Kit

SDA412

Breather Kit
MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES

50265410

MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES
NEXT ENC 96HX45WX11D N1 PAINTED

ER9645A

NEXT ENC 96HX45WX11D N1 PAINTED
Plug, Knockout, Plastic, Size 3/4 Inch

9892

Plug, Knockout, Plastic, Size 3/4 Inch
3/4 Inch, Non-Metallic Insulated Bushing, For Use with Rigid/IMC Conduit, Bag of 5

BU502-5

3/4 Inch, Non-Metallic Insulated Bushing, For Use with Rigid/IMC Conduit, Bag of 5
8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

H8084HLL

8x8x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

How to Install the CEPL1424 Cable Entry Gland Plate

This guide provides step-by-step instructions for installing the CEPL1424 Cable Entry Gland Plate into a cutout for effective cable management.

Estimated time: 15m

Tools needed:

Screwdriver

Supplies needed:

Cable entry gland plate, Cables

  1. Prepare the cutout

    Ensure the cutout is clean and free of debris to facilitate a proper fit for the cable entry gland plate.

  2. Insert the cable entry gland plate

    Place the cable entry gland plate into the cutout, aligning it properly for a secure fit.

  3. Push cables through

    Pierce the membrane at the designated push-through point and push the cables through from the outside.

  4. Secure the gland plate

    Press the cable entry gland plate until all four sides snap securely into the cutout.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.