Authorized nVent Distributor
nVent CEPL1224 - Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 12 Entry, GY, Plastic

nVent CEPL1224 Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 12 Entry, GY, Plastic

UPC: 783510582951


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent CEPL1224 Rectangular Cable Entry Plate (SKU: CEPL1224) provides efficient and secure cable management for industrial enclosures, ideal for high-density cable entry in limited spaces. This robust plastic gland plate offers a fast, economical, and tool-free solution for introducing multiple cables and pneumatic conduits into control panels and junction boxes. Its snap-in fastening system is compatible with wall thicknesses from 1.4 to 2 mm, reducing assembly time, and also supports screw mounting for enhanced security. The integrated TPU/NBR/EPDM seal ensures IP 65 protection against dust and moisture. Constructed from halogen-free Polyamide, it operates effectively between -30ºC and +70ºC and is flame retardant (V-0 according to UL94). With dimensions of 44x142x12mm, this gray entry plate maximizes space utilization with 12 openings, contributing to organized and maintainable electrical installations in manufacturing, automation, and infrastructure sectors.
  • Finish: Gray
  • Pack quantity: 10
  • Description: Fast, cost-effective and tool-free cable entry for incoming cables and/or pneumatic conduits inside an enclosure. The snap-in system works for wall thicknesses of 1.5 to 2.5 mm.
  • Temperature resistance: -40°C to +90°C
  • Flammability: UL94 V-0
  • Protection: IP54, NEMA 1, 12
  • Material: TPE

Specifications

Application
Controls and Drives;Corrosive Environments
Application
Corrosive Environments; Controls and Drives
Cable Entry
(12) 0.04 - 0.59 ";(12) 1.0 - 15.0 mm
Cable Entry
(12) 1.0 - 15.0 mm
Cable Entry Quantity
12
Color
Gray
Color
Grey
Configuration
12 x 1.0-15.0mm (.04-.59)
Cutout Size
18.69 x 7.19 in
Cutout Size
1.42 x 4.41 in
Cutout Size
36x112 mm
Depth
12 mm
Depth
0.47 in
Finish
Untreated
Height
1.73 in
Height
44 IN
Height
44 mm
Material
Plastic
Operating Temperature
-40-90 °C
Operating Temperature
-40-194 °F
Product Family
Cable Manager
Protection Rating
NEMA Type 1
Type
Cable Entry Systems
Weight
32 lbs./100ft
Weight
0.04036281 kg
Weight
0.09 lb
Weight
0.089 lb
Width
142 mm
Width
5.59 in
Works With
NEMA
Package Dimensions (L x W x H)
9 IN x 5 IN x 1 IN
Package Dimensions (L x W x H)
22.86 cm x 12.7 cm x 2.54 cm
Package Weight (Imperial)
0.250 L
Package Weight (Metric)
0.113 kg
Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 18 Entry, GY, Plastic

CEPL1824

Cable Entry Gld Plt Rectangular, CEPL, 44x142x12mm 18 Entry, GY, Plastic
RAINHOOD N4 GY

RH20000N4GY

RAINHOOD N4 GY
A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.

RCR75J

A retrofit cable connector for nonmetallic sheathed cable and NM-B nonmetallic cable. It is made of plastic and comes in grey. The size is 3/4" and it is designed for 1-cable use.
Grey plastic hinges (2 pcs)

TH A

Grey plastic hinges (2 pcs)
MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES

50265410

MULTIPOLAR FLAT MOUNTING BUSBAR SUPPORT SB 6500 4 POLES
NEXT ENC 96HX45WX11D N1 PAINTED

ER9645A

NEXT ENC 96HX45WX11D N1 PAINTED
Plug, Knockout, Plastic, Size 3/4 Inch

9892

Plug, Knockout, Plastic, Size 3/4 Inch
Staples, Cable, Size 3/4 Inch, Plastic, For use with 3-Wire #10 or #12 Romex UF up to 9/16 Inch Wire, Pack of 500

17-215

Staples, Cable, Size 3/4 Inch, Plastic, For use with 3-Wire #10 or #12 Romex UF up to 9/16 Inch Wire, Pack of 500
8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

H8064HLL

8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting Feet

Frequently Asked Questions

What is the operating temperature range for CEPL cable entries?

CEPL cable entries can withstand temperatures from -40°C to +90°C (-40°F to 194°F).

What is the flammability rating of the CEPL cable entries?

The CEPL cable entries have a UL94 V-0 flammability rating.

What protection ratings do the CEPL cable entries meet?

The CEPL cable entries meet IP54, NEMA Type 1, and NEMA Type 12 protection ratings.

How many cables can be entered using the CEPL1224?

The CEPL1224 allows for 12 cable entries, with individual cable sizes ranging from 0.04 to 0.59 inches.

What are the dimensions of the CEPL1224 cutout size?

The cutout size required for the CEPL1224 is 1.42 inches by 4.41 inches.

What is the material of the CEPL cable entries?

The CEPL cable entries are made of TPE plastic.

Can CEPL cable entries be installed without tools?

Yes, CEPL cable entries can be installed quickly and easily without the need for tools.

What is the pack quantity for CEPL cable entries?

The CEPL cable entries are sold in packs of 10.

What is the weight of a single CEPL cable entry?

Each CEPL cable entry weighs 0.09lb.

What wall thicknesses are compatible with the CEPL snap-in system?

The snap-in system for CEPL entries works with wall thicknesses from 1.5 to 2.5 mm.

How to Install the CEPL1224 Cable Entry Gland Plate

This guide provides step-by-step instructions for installing the CEPL1224 Cable Entry Gland Plate, ensuring proper cable management and secure installation.

Estimated time: 15m

Tools needed:

Screwdriver

Supplies needed:

Cable entry gland plate, Cables

  1. Prepare the cutout

    Ensure the cutout for the cable entry gland plate is clean and free of debris.

  2. Insert the cable entry gland plate

    Place the cable entry gland plate into the prepared cutout, aligning it properly.

  3. Push cables through

    Pierce the membrane at the push-through point and push the cables through from the outside.

  4. Secure the gland plate

    Press the gland plate into the cutout until all four sides snap securely into place.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.