nVent CEPH2024 Cable Entry Gld Plt Rectangular, CEPH, 58x150x12mm 20 Entry, Blk, Plastic
UPC: 783510583095
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Description: Fast, cost-effective cable entry with a tight seal for incoming cables and/or pneumatic conduits inside an enclosure. Can be affixed with screws or the built-in snap-in system that works for wall thicknesses of 1.5 to 2.5 mm.
- Finish: Black
- Flammability: UL94 V-0
- Material: Polyamide 6.6 / TPE
- Pack quantity: 1 pc
- Protection: IP66, NEMA 1, 4x, 12 (Indoor use only)
- Temperature resistance: -40°C to +90°C
Specifications
Application | Controls and Drives;Corrosive Environments |
Application | Corrosive Environments; Controls and Drives |
Cable Entry | (12) 0.13 - 0.25 ";(12) 3.2 - 6.3 mm |
Cable Entry | (12) 0.13 - 0.25 " |
Cable Entry Quantity | 20 |
Color | Black |
Configuration | 12 x 3.2-6.3mm (.13-.25) |
Cutout Size | 36x112 mm |
Cutout Size | 1.42 x 4.41 in |
Cutout Size | 18.69 x 7.19 in |
Depth | 0.47 in |
Depth | 12 mm |
Finish | Bare/Untreated |
Finish | Untreated |
Height | 58 mm |
Height | 58 |
Height | 44 IN |
Height | 2.28 in |
Material | Plastic |
Operating Temperature | -40-194 °F |
Operating Temperature | -40-90 °C |
Product Family | Cable Manager |
Protection Rating | NEMA Type 1 |
Type | Cable Entry Systems |
Weight | 0.1 kg |
Weight | 32 lbs./100ft |
Weight | 0.268 lb |
Width | 149.6 mm |
Width | 149.6 |
Width | 5.89 in |
Width | 23 IN |
Works With | NEMA |
Package Dimensions (L x W x H) | 8 IN x 3 IN x 1 IN |
Package Dimensions (L x W x H) | 20.32 cm x 7.62 cm x 2.54 cm |
Package Weight (Imperial) | 0.270 L |
Package Weight (Metric) | 0.123 kg |
Frequently Asked Questions
What is the operating temperature range for the CEPH2024?
The CEPH2024 can operate in temperatures ranging from -40°C to +90°C (-40 to 194°F).
What industry standards does the CEPH2024 comply with?
It is UL 508A Component Recognized, Type 1, 12, 4X (indoor only), UL94 V-0 Flammability, NEMA Type 1, 12, 4X (indoor only), CE, and IP66 rated.
What are the cable entry size ranges for the CEPH2024?
It has (12) entries for 0.13 to 0.25 inch cables and (8) entries for 0.22 to 0.41 inch cables.
What is the protection rating of the CEPH2024?
The CEPH2024 offers IP66, NEMA 1, 4x, and 12 protection for indoor use only.
What are the dimensions of the CEPH2024 cable entry plate?
The CEPH2024 cable entry plate measures 58x150x12mm.
What is the flammability rating of the CEPH2024?
The CEPH2024 has a UL94 V-0 flammability rating.
What materials is the CEPH2024 made from?
The CEPH2024 is made from Polyamide 6.6 and TPE.
How many cables can the CEPH2024 accommodate?
The CEPH2024 can accommodate 20 cables.
What is the required cutout size for installing the CEPH2024?
The required cutout size for the CEPH2024 is 1.42 x 4.41 inches.
How is the CEPH2024 affixed to an enclosure?
It can be affixed with screws or using the built-in snap-in system for wall thicknesses of 1.5 to 2.5 mm.
How to Install the Cable Entry Gland Plate for CEPH
This guide provides step-by-step instructions for installing the Cable Entry Gland Plate for the CEPH system, ensuring proper mounting and cable management.
Estimated time: 30m
Tools needed:
Screwdriver, Torque wrench
Supplies needed:
M4 screws, Cable entry gland plate
- Prepare the installation site
Ensure the installation area is clean and free of debris. Verify that the surface is suitable for mounting the cable entry gland plate.
- Mount the cable entry gland plate
Align the cable entry gland plate with the mounting holes. Insert 4 M4 screws and torque them to 3 Nm (26 in-lbs) to secure the plate firmly.
- Insert cables through the gland
Pierce the membrane at the designated push-through point and push the cables through to the inside of the enclosure, ensuring a snug fit.
- Secure the installation
Verify that the cables are properly seated and that the gland plate is securely mounted. Check for any gaps or loose fittings.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.