nVent AU84X4024LUCLP - Universal Free-Stand Left Side Open, 84.13x40.24x24.13, Gray, Steel, Univ CO
nVent

AU84X4024LUCLP

UPC: 783510571795


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent UF Series Universal Free-Stand Enclosure, model AU84X4024LUCLP, is engineered for robust protection of critical industrial equipment. Constructed from durable steel with a professional gray finish, this enclosure offers superior resistance to environmental factors and physical impact, ensuring operational continuity in demanding manufacturing and processing environments. Its generous dimensions of 84.13 inches in height, 40.24 inches in width, and 24.13 inches in depth provide ample space for complex control systems, power distribution units, and other essential industrial components. The UF Series is designed with versatility at its core. The free-stand mounting type allows for flexible placement within your facility, eliminating the need for wall or floor mounting in many applications. This is particularly advantageous in dynamic industrial settings where reconfigurations may be necessary. The left-side open door configuration (LUCLP) offers convenient access for maintenance and operation, while the universal cutout design facilitates integration with a wide range of accessories and internal mounting solutions, enhancing customization for specific application needs. This enclosure is ideal for a multitude of industrial applications, including but not limited to: * **Industrial Automation:** Housing PLCs, HMIs, variable frequency drives (VFDs), and control panels. * **Power Distribution:** Protecting switchgear, transformers, and power distribution units. * **Process Control:** Safeguarding sensors, controllers, and communication equipment in chemical plants, water treatment facilities, and food processing operations. * **Data Centers & IT Infrastructure:** Providing a secure and controlled environment for networking equipment and servers in industrial settings. * **Renewable Energy:** Protecting inverters, battery storage systems, and grid connection equipment. nVent is a globally recognized leader in electrical enclosure solutions, renowned for their commitment to quality, innovation, and safety. The UF Series embodies this dedication, offering enhanced safety features to protect both equipment and personnel. The robust steel construction meets stringent industry standards, providing a reliable barrier against dust, moisture, and other contaminants. Furthermore, the modular design of the UF Series allows for baying multiple enclosures together, enabling the creation of application-specific configurations that can scale with your operational requirements. Accessories are readily available to further enhance end-user safety, such as interlocks and grounding kits, or to maximize internal panel space for additional equipment. When selecting an enclosure for critical industrial applications, factors such as environmental protection, accessibility, scalability, and manufacturer reliability are paramount. The nVent UF Series Universal Free-Stand Enclosure AU84X4024LUCLP excels in all these areas, providing a secure, flexible, and durable solution designed to meet the rigorous demands of modern industry. Its robust construction, thoughtful design, and the trusted nVent brand ensure that your valuable equipment remains protected and your operations run smoothly and safely.
  • Seams are continuously welded and ground smooth
  • Body stiffeners in larger enclosures for extra rigidity
  • Body flange trough excludes liquids and contaminants
  • Heavy-duty lifting eyes anchor into reinforced top
  • Concealed, easy-to-remove hinges
  • Heavy-duty 3-point latching mechanism operated by padlocking handle on all doors
  • Order panels separately
  • Data pocket is high-impact thermoplastic
  • Oil-resistant door gasket
  • Bonding provision on door

Specifications

Application
Arc Flash Safety;Controls and Drives;Power Distribution
Application
Controls and Drives; Arc Flash Safety; Power Distribution
Body Thickness
11 ga
Body Thickness
16 ga
Body Thickness
3.04 mm
Color
Gray
Color Code
ANSI 61
Conductive Panel
A84PM40G
Cutout Type
Universal
Depth
613 mm
Depth
24.13
Depth
613
Door Thickness
12 ga
Door Thickness
2.66 mm
Door Thickness
14 ga
Finish
Powder Coating
Finish
Powder Coated
Height
84.13
Height
2,137
Height
2,137 mm
Material
Mild Steel
Material
Steel
Mounting Type
Free-stand
Painted Panel
A84PM40
Panel Size
1829 x 857 mm
Panel Size
72.00 x 33.75 in
Protection Rating
NEMA Type 4
Series
nVent UF
Size
84.13x40.24x24.13
Type
Mild Steel Freestanding Industrial Enclosures
Weight
402 lb
Width
1,022 mm
Width
40.24
Width
1,022
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the AU72X7818RSSLP Controller

This guide provides step-by-step instructions for installing and configuring the AU72X7818RSSLP controller, including wiring and calibration procedures.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the AU72X7818RSSLP controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use wire strippers to prepare the wires and connect them to the appropriate terminals on the controller. Ensure all connections are tight and secure to prevent any electrical issues.

  3. Verify the connections

    Utilize a multimeter to check the voltage and continuity of the connections. Ensure that all readings are within the specified range to confirm proper installation.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters as per your system requirements. Save the settings to apply the configuration.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure the controller operates accurately. Adjust any settings as needed based on the calibration results.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.