Overview
- Baying Kit is used to bay multiple Universal Free-Stand Enclosures together.
- Includes gasket and baying hardware.
- Black rubber gasket (72.13x18.11x0.13 inches) with included hardware
- Resistant to ozone, UV, and chemicals for long-term durability
- Simplifies enclosure baying with pre-engineered installation kit
Specifications
Application | Arc Flash Safety;Controls and Drives;Power Distribution |
Application | Power Distribution; Arc Flash Safety; Controls and Drives |
Color | Black |
Consist Of | Gasket and fasenters |
Depth | 3 mm |
Depth | 0.13 in |
Finish | Smooth |
Height | 1,832 mm |
Height | 72.13 in |
Insulation | No |
Insulation | False |
Knockouts | No |
Knockouts | False |
Material | Foam;Rubber |
Material | Rubber |
Size | 72.126 x 18.110 x 0.13 inch |
Thickness | 0.13 in |
Thickness | 3 mm |
Thickness | 51.40mm (2.024") |
Type | Other Accessories |
Weight | 2.86 lb |
Width | 460 mm |
Width | 18.11 in |
Works With | NEMA |
Package Dimensions (L x W x H) | 20 IN x 14 IN x 2 IN |
Package Dimensions (L x W x H) | 50.8 cm x 35.56 cm x 5.08 cm |
Package Weight (Imperial) | 2.860 L |
Package Weight (Metric) | 1.297 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackFrequently Asked Questions
What is the purpose of the AU7218FGK Gasket Baying Kit?
The Gasket Baying Kit is used to bay multiple Universal Free-Stand Enclosures together.
What is included with the Gasket Baying Kit?
The kit includes the gasket and the necessary baying hardware.
What are the enclosure ratings for this baying kit?
The baying kit is rated for 4, 4X, 12, 3R, and IP66.
What are the dimensions of the AU7218FGK Gasket Baying Kit?
The dimensions are 72.13 inches in height, 18.11 inches in width, and 0.13 inches in depth.
What material is the Gasket Baying Kit made from?
The gasket is made of foam material.
What is the color and finish of the baying kit gasket?
The gasket is black with a smooth finish.
What is the weight of the AU7218FGK Gasket Baying Kit?
The weight of the gasket baying kit is 2.86lb.
How should nVent products be installed and used?
nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials.
Where can I find nVent product instruction sheets?
Instruction sheets are available at www.nvent.com and from your nVent customer service representative.
What are the consequences of improper installation or misuse?
Improper installation, misuse, or failure to follow instructions may cause product malfunction, property damage, serious bodily injury, death, and void the warranty.
How to Install the AU7218FGK Controller
This guide provides step-by-step instructions for mounting, wiring, and configuring the AU7218FGK Controller.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the AU7218FGK controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect wiring
Use wire strippers to prepare the wires and connect them to the appropriate terminals on the AU7218FGK controller. Ensure all connections are secure and insulated.
- Verify connections
Use a multimeter to check the voltage and continuity of the connections made. Ensure that all readings are within the specified range to confirm proper installation.
- Configure settings
Power on the AU7218FGK controller and access the configuration menu. Set the necessary parameters according to your application requirements.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure the AU7218FGK controller operates accurately. Adjust settings as needed based on the calibration results.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.