Contact for Pricing
Overview
- Type 316 stainless steel quarter-turn door latching
- 3-mm double-bit insert for security
- Slot and through-hole side-mount hanging brackets
- Lift-off door hinges
- Removable gland plates; one or three gland plates standard
- Internal/external brass earth/ground provision
- Type 316 stainless steel external fasteners
- Gray silicone high-temperature gasket on doors and gland plates; operating temperature range -55 C to +180 C
- Internal/external brass earth/ground provision
Specifications
Application | Hazardous Environments |
Color | Unpainted |
Conductive Panel | ATEX45P38G |
Depth | 6.3 in |
Depth | 160 mm |
Finish | Brushed #3 |
Gland Plate Quantity | 1 |
Height | 18.03 in |
Height | 458 mm |
IP Rating | IP66 |
Material | Stainless Steel 316L |
Material | Stainless Steel |
Modification Services | Yes |
NEMA Rating | 4X Watertight, corrosion-resistant |
Number of Gland Plate Openings | 1 |
Panel Size | 412 x 336 mm |
Panel Size | 16.23 x 13.24 in |
Product Family | Zonex |
Protection Rating | NEMA Type 12 |
Size | 458x382x160mm |
Thickness | 1.4 mm |
Thickness | 16 ga |
Type | Stainless Steel Wall Mounted Industrial Enclosures |
Type Number | Type 4X |
Weight | 22.2 lb |
White Panel | ATEX45P38 |
Width | 15.04 in |
Width | 382 mm |
Package Dimensions (L x W x H) | 21.7 IN x 20.8 IN x 8.4 IN |
Package Dimensions (L x W x H) | 55.118 cm x 52.832 cm x 21.336 cm |
Package Weight (Imperial) | 22.200 L |
Package Weight (Metric) | 10.070 kg |
How to Install the ATEX453816SS61 Enclosure
This guide provides step-by-step instructions for installing and configuring the ATEX453816SS61 enclosure, ensuring compliance with safety standards.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Cable glands
- Drill holes in gland plates
Drill holes in the gland plates only, ensuring no holes are closer than 1.625 inches from the edge. Verify that the selected gland will not interfere with the sealing washer and lock nut.
- Mount the enclosure
Secure the enclosure to the designated mounting surface using appropriate mounting screws. Ensure the enclosure is level and firmly attached.
- Connect grounding
Connect the internal body grounding terminal for equipment grounding and ensure the external connection is made for supplementary bonding as required by local codes.
- Install cable glands
Select and install the appropriate cable glands according to the manufacturer's instructions, ensuring all accessories such as locknuts and sealing washers are included.
- Verify electrical connections
Use a multimeter to verify all electrical connections are secure and correctly configured before powering on the enclosure.
- Conduct final inspection
Visually inspect gaskets, locks, and screws after each opening of covers or removing of gland plates to ensure proper sealing and safety.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.