Overview

The nVent AST4224R is a Type 1 splitter trough for centralized power distribution in industrial and commercial systems. It measures 48" L x 8" W x 5" D with a 16 or 14 gauge steel enclosure in ANSI 61 gray polyester powder paint. Rated 225A, it supports 4-wire configurations for high-demand applications in manufacturing, data centers, commercial buildings, and substations. Features include pre-installed terminal blocks for 3- and 4-wire systems, knockouts on all sides (2.5" on ends, 0.5–0.75" and 1–1.75" on sides, spaced 4.5" apart), hinged covers, and back-mounted installation holes. A single-point ground lug is included; a ground splitter bar accessory is available. 76 (Type 1), NEMA/EEMAC Type 1, and IEC 60529 IP30, it meets indoor general-purpose use standards. Distributed by Gross Automation.
  • Various size knockouts on each side
  • Hinged covers
  • Mounting holes in back
  • Includes single-point ground lug
  • Ground Splitter (ground bar) accessory available
  • 16 or 14 gauge steel

Specifications

Application
Power Distribution
Branch Lug Amps CU
150 A
Branch Lug Quantity
6
Branch Lug Wire Size
14-2/0
Branch Lug Wire Size
14 - 2/0 AWG
Color
Gray
Color
Grey
Color Code
ANSI 61
Connection Type
Terminal blocks
Current Rating
225 A
Depth
4.5 in
Depth
114.3 mm
Depth
13 IN
Depth
114
Finish
Powder Coated;Steel/Gray
Finish
Powder Coated
Height
1,219 mm
Height
48 in
Main Lug Amps CU
225 A
Main Lug Quantity
1
Main Lug Wire Size
6-300MCM kcmil
Material
Mild Steel
Material
Steel
Material
Mild Steel;Steel
Modification Services
Yes
NEMA Rating
Type 1
NEMA Rating
1 Indoor, electrical protection
Number Of Wires
4
Poles
4-wire
Protection Rating
NEMA Type 1
Series
AST
Size
48x8x5
Size
48" Section in
Size
48x8x5 inches
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Utility / Canadian Cabinets and Splitters
Type
Utility Cabinets
Type Number
Type 1
Weight
31.3 lb
Width
210
Width
8.25 in
Width
23 IN
Wire Quantity
4
Package Dimensions (L x W x H)
39 IN x 9.25 IN x 5 IN
Package Dimensions (L x W x H)
99.06 cm x 23.495 cm x 12.7 cm
Package Weight (Imperial)
31.300 L
Package Weight (Metric)
14.198 kg
Splitter Trough Type 1 4-wire 225 amps, 60x8x5, Gray, Steel

AST5224R

Splitter Trough Type 1 4-wire 225 amps, 60x8x5, Gray, Steel
Type 1 Gutter Trough w/KO - 4X4X12 - Steel/Gray

CGT1244

Type 1 Gutter Trough w/KO - 4X4X12 - Steel/Gray
Splitter Trough Type 1 4-wire 225 amps, 36x8x5, Gray, Steel

AST3224R

Splitter Trough Type 1 4-wire 225 amps, 36x8x5, Gray, Steel
Splitter Trough Type 1 4-wire 225 amps, 72x8x5, Gray, Steel

AST6224R

Splitter Trough Type 1 4-wire 225 amps, 72x8x5, Gray, Steel
Splitter Trough Type 1 4-wire 125 amps, 24x6x5, Gray, Steel

AST2124R

Splitter Trough Type 1 4-wire 125 amps, 24x6x5, Gray, Steel
Splitter Trough Type 1 4-wire 400 amps, 60x10x6, Gray, Steel

AST5404R

Splitter Trough Type 1 4-wire 400 amps, 60x10x6, Gray, Steel
Splitter Trough Type 1 4-wire 400 amps, 72x10x6, Gray, Steel

AST6404R

Splitter Trough Type 1 4-wire 400 amps, 72x10x6, Gray, Steel
Splitter Trough Type 1 3-wire 125 amps, 48x6x5, Gray, Steel

AST4123R

Splitter Trough Type 1 3-wire 125 amps, 48x6x5, Gray, Steel

How to Install the AST4224R Splitter Trough

This guide provides step-by-step instructions for installing and configuring the AST4224R Splitter Trough on a DIN rail.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the splitter trough

    Secure the AST4224R splitter trough to the DIN rail using the integrated clips. Ensure it is level and firmly attached.

  2. Connect the main wire feed

    Route the main wire feed through the appropriate knockout. If necessary, rotate the splitter block 180º and remount it in the top holes for proper alignment.

  3. Verify electrical clearances

    Before energizing any circuits, check all internal and external electrical and mechanical clearances to ensure safe and proper operation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.