
nVent ASE6X6X6SSNK Screw-Cover Type 4X, 6.00x6.00x6.00, Brushed, SS304
UPC: 783510305437
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Seams continuously welded and ground smooth
- Oil-resistant gasket and adhesive material used is tested to UL 94
- Captivated stainless steel cover screw threaded into sealed walls
- No holes or knockouts
- Grounding stud on inside back of box
- 10 to 16 gauge stainless steel
Specifications
Application | Power Distribution |
Body Thickness | 16 ga |
Color | Unpainted |
Cover Screw Quantity | 4 |
Depth | 6 in |
Depth | 152 mm |
Depth | 13 IN |
Depth, Maximum | 6 |
Depth, Minimum | 6 |
Door Thickness | 14 ga |
Door Thickness | 16 ga |
Finish | No. 2B |
Height | 44 IN |
Height | 6 IN |
IP Rating | IP66 |
Material | Stainless Steel 304 |
Material | Stainless Steel |
NEMA Rating | 4X |
NEMA Rating | NEMA 6 |
Protection Rating | NEMA Type 4X |
Type | Pull and Junction Boxes |
Type | Screw-Cover Pull Box Type 4X |
Type Number | Type 3R |
Weight | 4.5 lb |
Width | 152 |
Width | 152 mm |
Width | 6 IN |
Package Dimensions (L x W x H) | 9.2 IN x 8.1 IN x 7.1 IN |
Package Dimensions (L x W x H) | 23.368 cm x 20.574 cm x 18.034 cm |
Package Weight (Imperial) | 4.500 L |
Package Weight (Metric) | 2.041 kg |
How to Install the ASE6X6X6SSNK Controller
This guide provides step-by-step instructions for installing and configuring the ASE6X6X6SSNK Controller on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the ASE6X6X6SSNK controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect power supply
Use wire strippers to prepare the power supply wires and connect them to the designated power terminals on the controller. Ensure the connections are tight and secure.
- Verify connections
Use a multimeter to check the voltage at the power terminals to ensure proper power supply. Confirm that the voltage matches the specifications outlined in the controller manual.
- Configure initial settings
Access the controller's configuration interface and input the necessary parameters as per your application requirements. Save the settings before exiting.
- Calibrate the controller
Follow the calibration procedure as specified in the manual to ensure accurate readings and performance. Adjust settings as needed based on calibration results.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.
