Overview
- Use 4.00 x 4.00-in. (102 x 102-mm) pedestal with Concept HMI and InLine HMI Enclosures
- Use 8.00 x 8.00-in. (203 x 203-mm) pedestal with ProLine Sloped-Front HMI Enclosures
- Attach pedestal to HMI base with cutout, swivel, swivel tilt or angle adapter with pre-drilled holes
- Hardware and gasket to attach enclosure are included
- Compatible with nVent CONCEPT and INLINE HMI enclosures
Specifications
Application | Controls and Drives |
Color | Gray |
Color | Ansi 61;Gray |
Color Code | ANSI 61 |
Depth | 102 mm |
Depth | 4 in |
Finish | Powder Coated |
Height | 26 in |
Height | 660 mm |
Height | 44 IN |
Material | Mild Steel |
Material | Steel |
Material | Mild Steel;Steel |
Modification Services | Yes |
Mounting Type | Bolt-down with optional casters |
Series | nVent AP Series |
Size | 26.00x4.00x4.00 in |
Thickness | 1.9 mm |
Thickness | 14 ga |
Thickness | 51.40mm (2.024") |
Type | Pedestals |
Weight | 34.1 lb |
Width | 102 mm |
Width | 4 IN |
Package Dimensions (L x W x H) | 36.25 IN x 11.2 IN x 4.8 IN |
Package Dimensions (L x W x H) | 92.075 cm x 28.448 cm x 12.192 cm |
Package Weight (Imperial) | 34.100 L |
Package Weight (Metric) | 15.468 kg |

44-BL
Bar Hanger, Length 26 Inches, Steel, Deep Offset 1-1/2 Inch for Mounting 1-1/2 Inch Deep Boxes with Plaster Ring, Furnished with Stove bolt
AB763
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
BMB24T
Telescoping box mounting bracket for stud spacing from 17 to 26 in. It is used with 1-1/2 in. or 2-1/8 in. electrical boxes. The bracket is made of pregalvanized steel and has a silver color.
H8064HLL
8x6x4 Polycarbonate Enclosure NEMA 4X | Hinged Cover | Gray | Stainless Steel Locking Latch | Mounting FeetHow to Install the AP26L44 Wall-Mount Enclosure
This guide provides instructions for installing and mounting the AP26L44 Wall-Mount Enclosure.
Estimated time: 1h
Tools needed:
Drill, Level, Measuring tape, Screwdriver, Wrench
Supplies needed:
Mounting hardware (screws, bolts, anchors), Gasket sealant (if required), Wire management accessories
- Select Mounting Location
Choose a suitable location for the enclosure. Ensure the mounting surface is strong enough to support the weight of the enclosure and its contents. Consider environmental factors such as temperature, humidity, and potential physical impacts. Verify that the location allows for adequate ventilation if required by the equipment inside. Check the enclosure's nameplate or datasheet for any specific environmental or location restrictions.
- Prepare Mounting Surface
Using a level and measuring tape, mark the mounting hole locations on the selected surface. Drill pilot holes as needed, ensuring they are appropriate for the chosen mounting hardware. If the enclosure is to be mounted on a concrete surface, use appropriate anchors. Clean the mounting surface to ensure a secure fit.
- Mount the Enclosure
Position the AP26L44 Wall-Mount Enclosure against the prepared mounting surface. Align the enclosure's mounting holes with the marked locations or pilot holes. Secure the enclosure using the appropriate mounting hardware (screws, bolts). Ensure the enclosure is mounted securely and level. Do not overtighten fasteners, as this could damage the enclosure or mounting surface. Refer to the nameplate or datasheet for specific torque values if provided.
- Install Gasket and Seal (If Applicable)
If your enclosure came with a gasket, ensure it is properly seated in the groove to maintain the enclosure's environmental rating. If required for your installation environment, apply gasket sealant around the door or lid edges to further enhance protection against dust and moisture. Refer to the nameplate or datasheet for specific sealing instructions.
- Install Internal Components and Wiring
Install any internal mounting plates, rails, or brackets as needed for your equipment. Route wiring through the designated conduit entries or cable glands, ensuring proper strain relief. Use wire management accessories to keep wiring neat and organized. Ensure all electrical connections comply with relevant codes and standards. Consult the nameplate or datasheet for specific wiring guidelines or component compatibility.
- Final Inspection and Closure
Perform a final inspection to ensure all components are securely mounted and all wiring is correctly installed and terminated. Close and latch the enclosure door securely. Verify that the enclosure is properly sealed to meet its environmental rating.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.