Contact for Pricing
Overview
- Mounts on enclosure frame and includes mounting hardware
- Mounting plate is 14 gauge
- Galvanized steel construction for corrosion resistance and durability
- Compatible with NEMA-rated enclosures and industrial control systems
- Manufactured in the US by nVent, a leader in electrical safety solutions
Specifications
Accessory Type | Lighting |
Application | Controls and Drives;Power Distribution |
Application | Power Distribution; Controls and Drives |
Color | Unpainted |
Depth | 22 mm |
Depth | 0.87 in |
Finish | Galvanized |
Height | 44 IN |
Height | 1.26 in |
Material | Mild Steel |
Modification Services | Yes |
Size | 115/230v 50/60Hz in |
Thickness | 51.40mm (2.024") |
Thickness | 1.9 mm |
Thickness | 14 ga |
Type | Electrical Accessories |
Weight | 0.25 lb |
Width | 17 mm |
Width | 0.67 in |
Works With | NEMA / IEC |
Package Dimensions (L x W x H) | 10.25 IN x 8 IN x 1 IN |
Package Dimensions (L x W x H) | 26.035 cm x 20.32 cm x 2.54 cm |
Package Weight (Imperial) | 0.250 L |
Package Weight (Metric) | 0.113 kg |

SV1218
Pre-Fabricated Floor-Track Vertical Mounting Bracket with Supporting Horizontal Cross Bar, 12 Inch or 18 Inch Height, For 4 Inch Square of 4-11/16 Inch Square Boxes, Deep or Shallow, with Standard Device Covers (Mud Rings)
BMB24
This is a 24" electrical box mounting bracket that mounts a 1-1/2" electrical box to studs on 24" centers. It is made of pre-galvanized steel. The finish/color is silver.How to Install the ALFSWD Door Switch
This guide provides step-by-step instructions for installing and wiring the ALFSWD Door Switch to ensure proper functionality and safety.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Spacers (if needed)
- Disconnect power
Before starting the installation, disconnect any power supplies to the enclosure to avoid electric shock and equipment damage.
- Mount the switch
Secure the ALFSWD Door Switch to the designated location using mounting screws. Ensure that the bracket is positioned correctly to allow the door to push the switch plunger between 3 mm and 13 mm.
- Connect the wiring
Follow the electrical schematic to connect the switch. Ensure all wiring complies with applicable national and local electrical codes. Use terminal connectors for secure connections.
- Verify connections
Use a multimeter to check all connections for continuity and proper voltage. Ensure that there are no short circuits before re-energizing the system.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.