nVent A72RA24TH - Rack Mounting Angle U Style Type RA, Full Length, fits 72x30, Steel
nVent

A72RA24TH

UPC: 783510745707


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent **Type RA Rack Mounting Angles (SKU: A72RA24TH)** are precision-engineered steel components designed to provide robust structural support for 24-inch (610-mm) rack-mounted equipment in free-standing enclosures. Engineered for compatibility with 72x30 mounting channels, these full-length U-style angles deliver unmatched stability, ensuring secure installation of critical IT, networking, and industrial equipment. Manufactured by nVent—a leader in thermal management and electrical infrastructure solutions—these rack mounting angles exemplify durability and compliance with industry standards. The full-length 61.25-inch (1556 mm) design ensures comprehensive coverage across the entire rack depth, eliminating the need for multiple shorter angles and reducing installation time. Key features include high-strength steel construction for significant weight loads, U-style mounting compatibility with 72x30 channels, and easy installation with pre-drilled holes. Ideal for data centers, industrial automation, telecommunications, and broadcast environments where equipment rack integrity is paramount.
  • Type RA rack mounting angles have mounting holes .281 in. (7 mm) in diameter and spaced per EIA 310-D standard
  • Angles and mounting hardware are plated
  • All mounting hardware is furnished
  • Use clip nut package AN1032 to provide tapped holes at desired locations
  • Ideal for 19in and 24in rack-mounted equipment in IT, networking, and telecom applications

Specifications

Accessory Type
Mounting Accessories
Application
Controls and Drives;Corrosive Environments;Power Distribution
Application
Corrosive Environments; Controls and Drives; Power Distribution
Color
Unpainted
Finish
Zinc Plated
Fits Enclosure
72.00 x 30.00 in
Fits Enclosure
1829 x 762 mm
Fits Enclosure Size
72.00 x 30.00 in
Fits Enclosure Size
24.00 x 20.00 in
For Rack Size
483 mm
For Rack Size
24 in
For Rack Size
610 mm
Material
Mild Steel;Steel
Material
Mild Steel
Modification Services
Yes
Size
fits 72.06x24.06 in
Thickness
1.9 mm
Thickness
14 ga
Thickness
51.40mm (2.024")
Type
Internal Mounting for Industrial Enclosures
Unit Quantity
35
Use With
A72H3124FS
Weight
19 lb
Works With
NEMA
Package Dimensions (L x W x H)
65.25 IN x 5.75 IN x 5 IN
Package Dimensions (L x W x H)
165.735 cm x 14.605 cm x 12.7 cm
Package Weight (Imperial)
19.000 L
Package Weight (Metric)
8.618 kg
Rack Mounting Angle U Style Type RA, Full Length, fits 90.x24, Steel

A90RA19TH

Rack Mounting Angle U Style Type RA, Full Length, fits 90.x24, Steel
Telescoping box mounting bracket and stud box support. It is made of pregalvanized steel with a silver finish. The sheet states spacing of 11 to 18 in. and use with 1-1/2 in. or 2-1/8 in. electrical boxes.

BMB16T

Telescoping box mounting bracket and stud box support. It is made of pregalvanized steel with a silver finish. The sheet states spacing of 11 to 18 in. and use with 1-1/2 in. or 2-1/8 in. electrical boxes.
Pre-Fabricated Floor-Track Vertical Mounting Bracket with Supporting Horizontal Cross Bar, 12 Inch or 18 Inch Height, For 4 Inch Square of 4-11/16 Inch Square Boxes, Deep or Shallow, with Standard Device Covers (Mud Rings)

SV1218

Pre-Fabricated Floor-Track Vertical Mounting Bracket with Supporting Horizontal Cross Bar, 12 Inch or 18 Inch Height, For 4 Inch Square of 4-11/16 Inch Square Boxes, Deep or Shallow, with Standard Device Covers (Mud Rings)
NEMA 1 Flush Lock Kit

1427LKN1

NEMA 1 Flush Lock Kit
ARCA JIC 10 x 8 x 6 with knockouts, hinged opaque cover, SS latch, padlockable

ARK1086CHSSL

ARCA JIC 10 x 8 x 6 with knockouts, hinged opaque cover, SS latch, padlockable
NEXT ENC 84HX30WX11D N1 PAINTED

ER8430A

NEXT ENC 84HX30WX11D N1 PAINTED
STEEL SQUARES 25X25X19 WITH HOLES 7MM

50000045

STEEL SQUARES 25X25X19 WITH HOLES 7MM
Feed through Terminal Blocks

DS1.5-QU-01P-11-00Z(H)

Feed through Terminal Blocks

How to Install the A90RP24F6 Relay Rack Angle

This guide provides step-by-step instructions for installing the A90RP24F6 Relay Rack Angle securely in your setup.

Estimated time: 30m

Tools needed:

Screwdriver

Supplies needed:

Clamping nuts, Spacers, Screws, Lockwashers, Washers

  1. Prepare the mounting area

    Place the clamping nuts in the mounting channels as shown in the installation diagram.

  2. Install spacers

    Place a spacer over each clamping nut to ensure proper spacing for the relay rack angle.

  3. Secure the relay rack angle

    Position the relay rack angle over the spacers and secure it in place using screws, lockwashers, and washers to ensure a stable installation.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.