nVent A727220USSLP - Two-Door Floorstand 3-Pt Latch Type 12, 72x72x20, Brushed, SS304
nVent

A727220USSLP

UPC: 783510842406


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent A727220USSLP Two-Door Floorstand Enclosure delivers robust protection for industrial control systems, automation panels, and sensitive electronics in demanding environments. Engineered with Type 304 brushed stainless steel, this Type 12-rated enclosure (72x72x20 inches) provides superior resistance to dust, dirt, oil, and water ingress, ensuring long-term reliability for mission-critical applications. Designed to house large components or complex mounting configurations, the A727220USSLP is ideal for facilities where environmental protection and operational durability are non-negotiable. This heavy-duty enclosure features a three-point latching system and industry-leading sealing technology, delivering NEMA Type 12 compliance for protection against corrosive atmospheres, splashing liquids, and particulate contamination. The brushed stainless steel finish not only enhances corrosion resistance but also provides a professional, low-maintenance surface suitable for food processing, pharmaceutical, chemical processing, and outdoor industrial applications. Professionals in automation, electrical distribution, and industrial automation rely on nVent’s enclosures for their precision engineering and compliance with international standards. The A727220USSLP is particularly well-suited for: - **Industrial Control Panels**: Safeguarding PLCs, HMIs, and variable frequency drives (VFDs) in manufacturing plants. - **Power Distribution**: Housing motor control centers (MCCs) and distribution boards in harsh or washdown environments. - **Telecommunications**: Protecting sensitive networking equipment in data centers or outdoor telecom shelters. - **Renewable Energy**: Enclosing inverters and battery management systems in solar or wind power installations. - **Water/Wastewater Treatment**: Shielding control systems from moisture, chemicals, and high-pressure washdowns. Installation is streamlined thanks to the floorstand design, which allows for secure mounting on concrete floors or elevated platforms. The two-door configuration provides easy access for maintenance while maintaining a tight seal when closed. nVent’s reputation for durable, code-compliant enclosures—backed by decades of innovation in thermal management and electrical protection—makes the A727220USSLP a trusted choice for engineers and facility managers prioritizing longevity and performance. Compatible with a wide range of accessories, including gland plates, cooling units, and mounting hardware, this enclosure adapts to evolving system requirements without compromising protection. For projects demanding Type 12 durability, corrosion resistance, and modular flexibility, the nVent A727220USSLP stands as a benchmark in industrial-grade protection.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • Strong, rigid construction with body stiffeners
  • Gasketed overlapping doors eliminate need for centerpost
  • Plated steel 3-point latching mechanism and key-locking handle
  • Heavy-gauge continuous hinges support each door
  • Data pocket, provided on door with 3-point latches, is high-impact thermoplastic
  • 12-in. (305-mm) floor stands are bolted to enclosure
  • Heavy-duty lifting eyes are Type 316 stainless steel
  • Panel supports
  • Collar studs for mounting optional panel

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Corrosive Environments; Controls and Drives; Hygienic Environments
Color
Brushed
Color
Unpainted
Depth
510 mm
Depth
20.06
Depth
510
Finish
Brushed #4
Galvanized Panel
A72P72G
Height
1,830 mm
Height
72.06
Height
1,830
IP Rating
IP55
Material
Type 304 Stainless Steel
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Floorstand
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
NEMA Rating
12
Panel
A72P72
Panel Gauge
11
Panel Size
68.00 x 68.00 in
Panel Size
1727 x 1727 mm
Protection Rating
NEMA Type 12
Series
nVent A727220USSLP
Size
72.06x72.06x20.06 in
Size
72x72x20 inches
Stiffener Body
1 (X-form)
Stiffener Body
1
Thickness
12 ga
Thickness
51.40mm (2.024")
Thickness
2.78 mm
Type
Stainless Steel Freestanding Industrial Enclosures
Weight
674 lb
Width
1,830 mm
Width
72.06
Width
1,830
Package Dimensions (L x W x H)
84 IN x 36 IN x 94 IN
Package Dimensions (L x W x H)
213.36 cm x 91.44 cm x 238.76 cm
Package Weight (Imperial)
674.000 L
Package Weight (Metric)
305.726 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A907224SSFSDADN4 Disconnect Device

This guide provides step-by-step instructions for installing the A907224SSFSDADN4 disconnect device in a wall-mounted enclosure.

Estimated time: 45m

Tools needed:

Drill, Screwdriver

Supplies needed:

Mounting screws, Latch mounting hardware

  1. Drill mounting panel

    Drill the mounting panel according to the manufacturer's instructions for the disconnect device, ensuring proper alignment and clearance.

  2. Install operating handle

    Attach the operating handle to the enclosure flange using the provided holes. Follow the disconnect manufacturer's instructions for proper installation.

  3. Mount disconnect device

    Secure the disconnect device onto the panel, following the manufacturer's instructions for installation and adjustment to ensure proper functionality.

  4. Install door latch

    Use the latch bar and stud-type standoffs provided on the door to install the door latch. Follow the aftermarket installation instructions for proper setup.

  5. Adjust door catch

    Adjust the door catch and door catch bracket to ensure proper interlock with the disconnect operating handle, following the manufacturer's instructions.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.