Contact for Pricing
Overview
- Seams continuously welded and ground smooth
- Seamless foam-in-place gasket adjacent to monel mesh assures water-tight, dust-tight and EMI seal
- Stainless steel screws and clamps
- Removable door with continuous hinge
- Weldnuts provided for mounting optional panels and terminal kits
- Bonding provision on door
- Bonding provision on door
Specifications
Application | Controls and Drives;Corrosive Environments |
Body Thickness | 16 ga |
Color | Brushed |
Color | Unpainted |
Conductive Steel Panel | A6P4G |
Depth | 13 IN |
Depth | 4 in |
Depth, Maximum | 4 |
Depth, Minimum | 4 |
Door Thickness | 16 ga |
Door Thickness | 14 ga |
Finish | Brushed #4 |
Height | 44 IN |
Height | 6 IN |
Ip Rating | IP66/IP67 |
IP Rating | IP66 |
Material | Stainless Steel 304 |
Material | Stainless Steel;Stainless Steel 304 |
Material | SS304 |
Material | Stainless Steel |
Modification Services | Yes |
Mounting | Wall Mounting Brackets Available |
Mounting | 6.75 x 2.00 in |
Mounting Type | Continuous hinge with clamps |
NEMA Rating | NEMA 6 |
Nema Rating | Type 4X |
NEMA Rating | 4X |
Overall Dimensions | 7.50 x 4.94 in |
Overall Dimensions | 114 x 88 mm |
Panel Size | 4.88 x 2.88 in |
Panel Size | 72.00 x 72.00 in |
Protection Rating | NEMA Type 12 |
Size | 6.00x4.00x4.00 in |
Size | 6.00x4.00x4.00 |
Size | 6x4x4 inches |
Stainless Steel Panel | A6P4SS |
Type | Stainless Steel Industrial Terminal and Junction Boxes |
Type | Stainless Steel Terminal and Junction Boxes |
Type Number | Type 3R |
Weight | 3 lb |
Width | 102 mm |
Width | 4 IN |
Package Dimensions (L x W x H) | 7.5 IN x 5.25 IN x 4.5 IN |
Package Dimensions (L x W x H) | 19.05 cm x 13.335 cm x 11.43 cm |
Package Weight (Imperial) | 3.000 L |
Package Weight (Metric) | 1.361 kg |
Frequently Asked Questions
What material is the nVent A6044CHEMCSS enclosure made from?
The nVent A6044CHEMCSS enclosure is constructed from 16-gauge SS304 stainless steel.
What NEMA and IP ratings does this enclosure meet?
This enclosure meets NEMA/EEMAC Type 4, 4X, 12, 13 standards and has an IP66/IP67 rating.
What is the finish of the nVent A6044CHEMCSS enclosure?
The enclosure features a #4 brushed finish for a durable aesthetic.
What is the purpose of the monel mesh in the gasket?
The monel mesh in the seamless foam-in-place gasket provides an EMI seal, in addition to water-tight and dust-tight protection.
Are mounting panels or terminal kits included with this enclosure?
Weldnuts are provided for mounting optional panels and terminal kits. The enclosure itself does not include these items.
How to Install the Grounding Kit for E9PBY25M
This guide provides step-by-step instructions for installing the grounding kit for the E9PBY25M, ensuring proper electrical continuity and safety.
Estimated time: 15m
Tools needed:
Screwdriver, Torque wrench
Supplies needed:
10-32x5/8 screws, Keps nuts, 10-32 hex nuts, Lockwashers, Ground wire, Grounding label
- Insert the mounting screw
Insert the 10-32x5/8 screw through the designated hole in the panel.
- Secure the screw
Tighten the screw using a keps nut, ensuring that the nut penetrates into the paint for proper electrical continuity.
- Attach the ground wire
Connect the ground wire and secure it using a 10-32 hex nut.
- Install the lockwasher
Place a lockwasher under one of the screws securing the panel to ensure grounding between the panel and the enclosure. Do not exceed a torque of 30 in-lbs.
- Apply the grounding label
Attach the included grounding label adjacent to the bolt as indicated in the installation instructions.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.