Overview
- Drip shield top and seam-free sides, front and back
- Mounting holes on back of enclosure
- Mounting studs are provided on the enclosure body
- Cover is removable in the open position
- Door handles provided
- Provisions for padlocking
- No gasketing or knockouts
- Ground lug
- Mounting provisions for optional door stop
- Enclosures are finished with paint over plated surfaces
Specifications
Application | Power Distribution; Controls and Drives |
Body Thickness | 12 ga |
Body Thickness | 2.66 mm |
Color | Gray |
Color Code | ANSI 61 |
Depth | 279 |
Depth | 11 in |
Depth | 279 mm |
Door Thickness | 1.9 mm |
Door Thickness | 14 ga |
Finish | Galvanized |
Gauge | 12 ga |
Height | 1,219 mm |
Height | 48 in |
IP Rating | IP32 |
Material | Steel |
Material | Mild Steel |
Modification Services | Yes |
NEMA Rating | 3R Weather-resistant, except dust |
Protection Rating | NEMA Type 3R |
Size | 48.00x30.00x11.00 in |
Type | Utility Cabinets |
Type | Utility / Canadian Cabinets and Splitters |
Type Number | Type 3R |
Weight | 136 lb |
Width | 762 mm |
Width | 762 |
Width | 30 IN |
Package Dimensions (L x W x H) | 51.5 IN x 31.5 IN x 13.5 IN |
Package Dimensions (L x W x H) | 130.81 cm x 80.01 cm x 34.29 cm |
Package Weight (Imperial) | 136.000 L |
Package Weight (Metric) | 61.690 kg |

A303012CT
CT Enclosure / Screw Cover, Bulletin A90CT (Current transformer - Current Transformer Screw Cover Enclosures), Size/Dims: 30.00x30.00x12.00, Material: Steel, Finish:
A242412CT
CT Enclosure / Screw Cover, Bulletin A90CT (Current transformer - Current Transformer Screw Cover Enclosures), Size/Dims: 24.00x24.00x12.00, Material: Steel, Finish:
A363012CT
CT Enclosure / Screw Cover, Bulletin A90CT (Current transformer - Current Transformer Screw Cover Enclosures), Size/Dims: 36.00x30.00x12.00, Material: Steel, Finish:
A363612CT
CT Enclosure / Screw Cover, Bulletin A90CT (Current transformer - Current Transformer Screw Cover Enclosures), Size/Dims: 36.00x36.00x12.00, Material: Steel, Finish:Frequently Asked Questions
What are the dimensions of the A483011HCT enclosure?
The enclosure measures 48.00 inches in height, 30.00 inches in width, and 11.00 inches in depth.
What is the NEMA rating for this enclosure?
The A483011HCT is rated NEMA Type 3R for outdoor protection against rain, sleet, and external ice formation.
What material is the A483011HCT enclosure made of?
The enclosure is constructed from gray powder-coated steel with a 14-gauge thickness.
Is the A483011HCT suitable for outdoor use?
Yes, the Type 3R rating ensures protection against outdoor environmental conditions including rain and sleet.
Does the A483011HCT include mounting provisions?
Yes, the enclosure features pre-drilled mounting holes for simplified installation.
What applications is the A483011HCT designed for?
The enclosure is designed for outdoor current transformer protection in metering applications, including utility substations and industrial facilities.
How to Install Conduit Entry into A483011HCT Enclosures
Instructions for installing conduit entry into nVent Hoffman rainproof enclosures.
Estimated time: 30m
Tools needed:
Drill, Punch, Screwdriver
Supplies needed:
U.L. listed rain tight or liquid tight conduit hubs, Conduit, Locknuts, Locking bushing
- Determine Conduit Entry Location
Decide whether the conduit entry will be above or below live parts. Refer to the document for specific requirements for each scenario.
- Install Conduit Hubs (If Applicable)
If conduit entry is above live parts, use only U.L. listed rain tight or liquid tight conduit hubs. Install the hubs and conduit according to the hub manufacturer's instructions.
- Prepare Enclosure for Conduit
If conduit entry is below live parts, punch or drill the correct size hole for the conduit to be used, or use the appropriate knockout if provided. Refer to the table for correct hole sizes based on conduit size.
- Secure the Conduit
Secure the conduit using locknuts inside and out, or by using a locking bushing on the inside and a locknut on the outside. Ensure a tight and secure fit.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.