Contact for Pricing
Overview
- Vertical mount (VM) or horizontal mount (HM)
- 90 cubic feet maximum enclosure volume
- System face plate and mounting plate: Type 316L stainless steel
- Regulator body: zinc with enamel finish
- Manifold body: anodized aluminum with Type 316 stainless steel valves
- Enclosure pressure gauge: aluminum with enamel finish
- Gas supply gauge: poly case and nickel-plated tube
- Enclosure protection vent—90 degree
- Rapid exchange control valve
- Enclosure supply and enclosure reference bulkhead fittings: Type 316 stainless steel
Specifications
Application | Hazardous Environments |
Color | Unpainted |
Cubic Capacity | 90 cubic ft |
Finish | Tumbled |
Finish | Tumble |
Height | 5.5 in |
Height | 140 mm |
Material | Stainless Steel 316L |
Modification Services | Yes |
Mounting Type | Horizontal |
Size | 90CF in |
Size | 90 cubic feet |
Thickness | 1.98 mm |
Thickness | 14 ga |
Type | Other Accessories |
Volume | 2.55 |
Volume | 90 ft³ |
Volume | 2.55 m³ |
Weight | 12.6 lb |
Weight | 4.54 kg |
Width | 10.75 mm |
Width | 273 mm |
Works With | NEMA / IEC |
Package Dimensions (L x W x H) | 18.4 IN x 17.9 IN x 10.7 IN |
Package Dimensions (L x W x H) | 46.736 cm x 45.466 cm x 27.178 cm |
Package Weight (Imperial) | 12.600 L |
Package Weight (Metric) | 5.715 kg |
How to Install the A3003YZHM Controller
This guide provides step-by-step instructions for installing and configuring the A3003YZHM Controller for effective operation in hazardous environments.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter, Drill with hole saw
Supplies needed:
Mounting screws, Terminal connectors, Enclosure Protection Vent, Gasket for Enclosure Pressure Gauge
- Mount the controller
Secure the A3003YZHM Controller to the designated mounting surface using the provided mounting screws. Ensure the controller is level and that all components are clear of obstructions.
- Connect the wiring
Using wire strippers, prepare the wires for connection. Connect the power supply wires to the designated terminals on the controller, ensuring correct polarity. Use a multimeter to verify connections.
- Install the Enclosure Protection Vent
Drill a hole in the protected enclosure for the Enclosure Protection Vent using a 1.6875" hole saw. Insert the vent hub through the hole and secure it with the provided nut, ensuring the O-ring is properly positioned to prevent leaks.
- Configure the controller settings
Access the controller's configuration interface and set the required parameters for pressure monitoring and gas exchange rates according to the specifications outlined in the manual.
- Calibrate the system
Perform a calibration of the pressure settings by connecting a differential pressure indicator to the enclosure. Adjust the settings on the controller until the desired pressure levels are achieved.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.