Authorized nVent Distributor
nVent A20P16 - Panel for Type 3R 4 4X 12 13 Enclosure, fits 20x16, White, Steel

nVent A20P16 Panel for Type 3R 4 4X 12 13 Enclosure, fits 20x16, White, Steel

UPC: 783510231507


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent A20P16 is a 12-gauge painted steel panel designed for 20x16 inch enclosures. It measures 17 inches in height and 13 inches in width (Panel Size D x E), providing a robust internal surface for component mounting and organization. This panel features 4 holes and 0 edge flanges, ensuring a secure fit within compatible nVent enclosures. Constructed from mild steel with a white powder-coated finish, the A20P16 offers durability and protection for sensitive electrical and electronic components. It is suitable for use in Wall-Mount and Free-stand/Floor-Mount Enclosure types. The precise dimensions and material contribute to maintaining the integrity of the enclosure system. Ideal for industrial automation, telecommunications, and process control applications, this panel facilitates efficient wiring and maintenance. The nVent A20P16 is a practical component for organizing internal enclosure layouts, ensuring components are securely housed and accessible for service. Its white color and powder-coated finish provide a clean and professional appearance within the enclosure. This panel is a key accessory for building reliable electrical and control systems in various industrial settings.
  • Panel mounting hardware is furnished with all enclosures which accept these panels
  • Panel dimensions: 17" Height x 13" Width (D x E)
  • White powder-coated finish for corrosion resistance
  • Features 4 holes for component mounting
  • Designed for use in nVent Wall-Mount and Free-stand/Floor-Mount Enclosures

Specifications

Accessory Type
Panels and Panel Accessories
Application
Arc Flash Safety;Controls and Drives;Corrosive Environments;Power Distribution
Application
Corrosive Environments; Power Distribution; Controls and Drives; Arc Flash Safety
Color
White
Edge Flange Quantity
0
Finish
Powder Coated
Gauge
12 ga
Height
17 IN
Height
432 mm
Hole Quantity
4
Material
Mild Steel
Material
Steel
Material
Mild Steel;Painted steel
Modification Services
No
Mounting Type
Wall-Mount, Free-stand/Floor-Mount
Nema Rating
Type 3R/4/4X/12/13
NEMA Rating
Type 3R
Nema Rating
Type 3R, 4, 4X, 12, 13
Panel Gauge
12 ga.
Panel Size
17.00 x 13.00 in
Panel Size
432 x 330 mm
Series
nVent
Series
A20P16
Size
fits 20x16 in
Size
20x16
Size
Fits 20x16 enclosures
Thickness
0.1 in
Thickness
2.66 mm
Thickness
51.40mm (2.024")
Type
Industrial Panels and Panel Accessories
Weight
6.7 lb
Width
330 mm
Width
13 IN
Works With
NEMA
Package Dimensions (L x W x H)
20.5 IN x 17 IN x 0.25 IN
Package Dimensions (L x W x H)
52.07 cm x 43.18 cm x 0.635 cm
Package Weight (Imperial)
6.700 L
Package Weight (Metric)
3.039 kg
Panel for Type 3R 4 4X 12 13 Enclosure, fits 20x12, White, Steel

A20P12

Panel for Type 3R 4 4X 12 13 Enclosure, fits 20x12, White, Steel
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder

AB253

The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
Panel for Type 3R 4 4X 12 13 Enclosure, fits 60x30, White, Steel

A60P30

Panel for Type 3R 4 4X 12 13 Enclosure, fits 60x30, White, Steel
Panel for Free-Stand with Mounting Channel Full-Length, fits 72x24, White, Steel

A72P24F1

Panel for Free-Stand with Mounting Channel Full-Length, fits 72x24, White, Steel
Panel for Type 3R 4 4X 12 13 Enclosure, fits 16x16, Anodized, Aluminum

A16P16AL

Panel for Type 3R 4 4X 12 13 Enclosure, fits 16x16, Anodized, Aluminum
Panel for Type 3R 4 4X 12 13 Enclosure, fits 24x20, White, Steel

A24P20

Panel for Type 3R 4 4X 12 13 Enclosure, fits 24x20, White, Steel
Panel for Type 3R 4 4X 12 13 Enclosure, fits 16x12, White, Steel

A16P12

Panel for Type 3R 4 4X 12 13 Enclosure, fits 16x12, White, Steel
Side-Mounted Panel for Free-Stand with Mounting Channel, fits A=90, 78x20, White

A90SMP20

Side-Mounted Panel for Free-Stand with Mounting Channel, fits A=90, 78x20, White

Frequently Asked Questions

What are the dimensions of the nVent A20P16 panel?

The nVent A20P16 panel has dimensions of 17 inches in height and 13 inches in width (Panel Size D x E).

What material is the nVent A20P16 panel made from?

The nVent A20P16 panel is constructed from 12-gauge mild steel with a white powder-coated finish.

How many holes does the nVent A20P16 panel have?

The nVent A20P16 panel features 4 holes for mounting components.

What type of enclosures is the nVent A20P16 panel compatible with?

The nVent A20P16 panel is designed for use in nVent Wall-Mount and Free-stand/Floor-Mount Enclosures.

What is the finish of the nVent A20P16 panel?

The nVent A20P16 panel has a white powder-coated finish.

How to Install a A20P16 Panel

This guide provides instructions for installing a A20P16 panel into an enclosure. Ensure you select the correct panel size and mounting hardware for your specific enclosure.

Estimated time: 30m

Tools needed:

Screwdriver, Drill (if mounting holes are not pre-drilled), Measuring tape

Supplies needed:

Mounting screws, Panel (A20P16), Enclosure

  1. Select the appropriate panel and enclosure

    Choose a A20P16 panel that is compatible with your enclosure size and type. Refer to the product documentation for compatibility charts and dimensions.

  2. Prepare the enclosure

    If necessary, drill mounting holes in the enclosure according to the panel's specifications. Ensure the enclosure is clean and free of debris.

  3. Mount the panel

    Position the A20P16 panel within the enclosure. Secure the panel using the appropriate mounting screws and hardware provided or recommended for your enclosure and panel type. Ensure the panel is level and firmly attached.

  4. Verify installation

    Check that the panel is securely mounted and does not move. Ensure all mounting hardware is tightened appropriately. If the panel is part of a system requiring specific ratings (e.g., NEMA, UL), verify that the installation maintains these ratings.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.